|+ style="text-align: left;" | Ionizing radiation dosimeters !Device !Photo !Mfg. country !Size, mm !Weight, g !Power supply !Display !Sound !Vibration !Detector type !Range, μSv/h !Range, μR/h !Measurement time, seconds !Measuring of beta and gamma radiation and range of energy !PC link !Extra features |
Radmetron PM1211{{Cite web |title=Electronic Dosimeter PM1211 |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/electronic-dosimeters/electronic-dosimeter-pm1211 |access-date=2025-05-01 |website=Radmetron}}
| |{{Flag|Belarus}} |128x48x20 |130 |1 CR2450 |LCD |{{Yes}} |{{No}} |0.01 – 10e4 |1.14 – 11.4e6 | |{{Yes|yes (48 keV – 3 MeV)}} |{{Yes|USB}} | |
Radmetron PM1300{{Cite web |title=Electronic Personal Dosimeter PM1300 |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/electronic-personal-dosimeter-pm1300 |access-date=2025-05-01 |website=Radmetron}}
| |{{Flag|Belarus}} |85x57x21 |95 |AAA |LCD |{{Yes}} |{{Yes}} |0.01 – 10e6 |1.14 – 11.4e5 |0 – 20 |{{Partial|X-ray and Gamma (15 keV – 20 MeV)}} |{{Yes|USB, RF-interface}} |GPS |
Radmetron PM1300GN{{Cite web |title=Electronic Personal Dosimeter PM1300GN |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/dozimetr-individualnyy-dkg-rm1300gn/#char |access-date=2025-05-02 |website=Radmetron}}
| |{{Flag|Belarus}} |130х57х35 |200 |built-in rechargeable, or optional AAA |LCD |{{Yes}} |{{Yes}} |Silicon PIN diode, scintillator, silicon photomultiplier |0.01 – 10e3 |1.14 – 11.4e7 |0 – 20 |{{Yes|Yes (0.025 eV – 15 MeV for neutron radiation, 15 keV – 20 MeV for photon radiation)}} |{{Yes|USB, RF-interface}} | |
Radmetron PM1401GNM{{Cite web |title=Personal Radiation Detector PM1401GNM |url=https://radmetron.com/en/product/personal-radiation-detectors/prd-gamma-neutron/personal-radiation-detector-pm1401k-01m/ |access-date=2025-05-04 |website=Radmetron}}{{Efn|{{langx|ru|PM1401K-01M}}}}
| |{{Flag|Belarus}} |195х57х32 |450 |1 АА |LCD |{{Yes}} |{{Yes}} |3He, Geiger–Müller tube, CsI(Tl) scintillator |0.1 – 9999 ±20% | |0.25 |{{Yes|Yes (0.033 – 3 MeV for gamma, 0.025 eV– 14 MeV for neutron)}} |{{Yes|USB}} | |
Radmetron PM1401MA{{Cite web |title=Gamma Personal Radiation Detector PM1401MA |url=https://radmetron.com/en/product/personal-radiation-detectors/prd-gamma/gamma-personal-radiation-detector-pm1401ma |access-date=2025-05-04 |website=Radmetron}}
| |{{Flag|Belarus}} |110×62×38 |320 |1 АА |LCD |{{Yes}} |{{Yes}} |CsI(Tl) scintillator |0.05 – 40 ±20% | |0.25 |{{Yes|Yes (0.05 – 3 MeV)}} |{{Yes|USB}} | |
Radmetron PM1401K-3{{Cite web |title=Multipurpose Hand-Held Radiation Monitor/Identifier PM1401K-3 |url=https://radmetron.com/en/product/radionuclide-identification-devices/multipurpose-hand-held-radiation-monitor-identifier-pm1401k-3 |access-date=2025-05-04 |website=Radmetron}}
| |{{Flag|Belarus}} |262x60x65 |820 |2 АА |{{Yes}} |{{Yes}} |3He, Geiger–Müller tube, CsI(Tl) scintillator |0.1 μSv/h – 100 mSv/h | | |{{Yes|Yes (150 keV – 3.5 MeV for beta radiation, 15 keV – 15 MeV for photon radiation)}} |{{Yes|USB}} |GPS |
Radmetron PM1401K-3M
| |{{Flag|Belarus}} |262x60x65 |820 |2 АА |{{Yes}} |{{Yes}} |Geiger–Müller tube, CsI(Tl) scintillator |0.1 μSv/h – 100 mSv/h | | |{{Yes|Yes (150 keV – 3.5 MeV for beta radiation, 15 keV – 15 MeV for photon radiation)}} |{{Yes|USB}} |GPS |
Radmetron PM1405P{{Cite web |title=Survey meter PM1405P |url=https://radmetron.com/en/product/contamination-measurement-monitors/dozimetr-radiometr-mks-rm1405r |access-date=2025-05-03 |website=Radmetron}}{{Efn|English name is not transliterated from Cyrillic. A transliteration would be "PM1405R"}}
| |{{Flag|Belarus}} |136×69×38 |340 |1 АА | |{{Yes}} |{{No}} |0.1 – 3e5 ±20% |11.4 – 34.2e6 ±20% | |{{Yes|Yes (50 keV – 3 MeV)}} |{{Yes|USB}} | |
Radmetron PM1603A{{Cite web |title=Wrist Gamma Dosimeter РМ1603A |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/electronic-dosimeters/wrist-gamma-dosimeter-rm1603a |access-date=2025-05-01 |website=Radmetron}}
| | rowspan="2" |{{Flag|Belarus}} | rowspan="2" |50х56х19 | rowspan="2" |85 | rowspan="2" |1 CR2032 | rowspan="2" |LCD with backlight |{{Yes}} |{{No}} | rowspan="2" |Geiger–Müller tube | rowspan="2" |0.01 – 10e3 | rowspan="2" |1.14 – 11.4e2 | |{{Yes|Yes (48 keV – 3 MeV)}} | rowspan="2" |IR adapter | rowspan="2" |alarm clock, timer, stopwatch, calendar |
Radmetron PM1603B{{Cite web |title=Wrist Gamma Dosimeter РМ1603B |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/electronic-dosimeters/wrist-gamma-dosimeter-rm1603b |access-date=2025-05-01 |website=Radmetron}}
| |{{Yes}} |{{No}} | |{{Yes|Yes (48 keV – 3 MeV)}} |
Radmetron PM1611{{Cite web |title=X-ray and Gamma Radiation Personal Dosimeter РМ1611 |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-pm1611/ |access-date=2025-05-02 |website=Radmetron}}
| |{{Flag|Belarus}} |60×65×22 |≤70 |built-in rechargeable |LCD |{{Yes}} |{{Yes}} |0.1 – 10e6 ±15% |11.4 – 11.4e8 ±15% |0 – 2 |{{Yes|Yes (20 keV – 10 MeV)}} |{{Yes|USB}} | |
Radmetron PM1611B
| |{{Flag|Belarus}} |60×65×25 |≤80 |AAA |LCD |{{Yes}} |{{Yes}} |0.1 – 10e6 ±15% |11.4 – 11.4e8 ±15% |0 – 2 |{{Yes|Yes (20 keV – 10 MeV)}} |{{Yes|USB}} | |
Radmetron PM1621{{Cite web |title=X-ray and Gamma Radiation Personal Dosimeter РМ1621 |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-rm1621/ |access-date=2025-05-02 |website=Radmetron}}
| |{{Flag|Belarus}} |87х72х39 |150 |1 АА |LCD |{{Yes}} |{{No}} |0.1 – 10e4 ±15% |11.4 – 11.4e6 ±15% | |{{Yes|Yes (10 KeV – 20 MeV)}} |IR adapter | |
Radmetron PM1621A{{Cite web |title=X-ray and Gamma Radiation Personal Dosimeter РМ1621A |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-rm1621a |access-date=2025-05-02 |website=Radmetron}}
| |{{Flag|Belarus}} |87х72х39 |165 |1 АА |LCD |{{Yes}} |{{No}} |0.1 – 10e5 ±15% |11.4 – 11.4e7 ±15% | |{{Yes|Yes (10 KeV – 20 MeV)}} |IR adapter | |
Radmetron PM1621M{{Cite web |title=X-ray and Gamma Radiation Personal Dosimeter РМ1621M |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-rm1621m/#char |access-date=2025-05-02 |website=Radmetron}}
| |{{Flag|Belarus}} |87х72х39 |185 |1 АА |LCD |{{Yes}} |{{No}} |0.01 – 10e4 ±15% |11.4 – 11.4e6 ±15% | |{{Yes|Yes (10 keV – 20 MeV)}} |IR adapter | |
Radmetron PM1621MA{{Cite web |title=X-ray and Gamma Radiation Personal Dosimeter РМ1621MA |url=https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-rm1621ma/ |access-date=2025-05-02 |website=Radmetron}}
| |{{Flag|Belarus}} |87х72х39 |185 |1 АА |LCD |{{Yes}} |{{Yes}} |0.01 – 10e5 ±15% |11.4 – 11.4e7 ±15% | |{{Yes|Yes (10 KeV – 20 MeV)}} |IR adapter | |
Ludlum Model 23{{Cite web |title=Model 23: mrem Electronic Personal Dosimeter |url=https://ludlums.com/products/all-products/product/model-23 |access-date=2025-04-10 |website=ludlums.com}}
| |{{Flag|Texas}}, United States |112.8x30x12 |55.9 |OLED |{{Yes}} |{{No}} |1 – 99.1e4 ≤±10% |114 – 11.4e7 ≤±10% | |{{Partial|X-ray and Gamma}} |IR reader | |
Ludlum Model 23-1{{Cite web |title=Model 23-1 mSv Electronic Personal Dosimeter - Ludlum Measurements Inc. |url=https://ludlums.com/products/all-products/product/model-23-1 |access-date=2025-04-10 |website=ludlums.com}}
| |{{Flag|Texas}}, United States |112.8x30x12 |55.9 |OLED |{{Yes}} |{{No}} |1 – 99.9e3 ≤±10% |114 – 11.47 ≤±10% | |{{Partial|Gamma and X-ray}} |IR reader | |
Ludlum Model K8{{Cite web |title=Model K8 NUKE Safeguard Personal Radiation Indicator - Ludlum Measurements Inc. |url=https://ludlums.com/products/all-products/product/model-k8 |access-date=2025-04-10 |website=ludlums.com}}
| |{{Flag|Texas}}, United States |39x25x13 |13 |LED |{{Yes}} |{{No}} | |0.01 – 99.9e7 | |{{Partial|gamma}} |{{No}} | |
Ludlum Model 25{{Cite web |date= |title=Model 25 Series: Personal Radiation Monitor |url=https://ludlums.com/images/data_sheets/M25-series.pdf |access-date=2025-04-10 |website=Ludlum Measurements}}{{Cite web |year=2014 |title=LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER’S MANUAL |url=https://ludlums.com/images/product_manuals/M25_&_M25-1.pdf |access-date=2025-04-10 |website=Ludlum Measurements}}{{Cite web |title=Model 25 Series |url=https://ludlums.com/products/all-products/product/model-25-series |access-date=2025-04-10 |website=ludlums.com}}
| |{{Flag|Texas}}, United States |76x54x17 |144 |2 lithium button cells |LCD with backlight |{{Yes}} |{{No}} |0.1 – 87.6e5 |10 – 99.9e7 | |{{Yes|Yes (60 keV – 2 MeV)}} | | |
Ludlum Model 25-1
| |{{Flag|Texas}}, United States |76x54x17 |144 |2 lithium button cells |LCD with backlight |{{Yes}} |{{No}} |1 – 99.9e5 |114 – 11.4e8 | |{{Yes|Yes (60 keV — 2 MeV)}} | | |
Ludlum Model 25-IS{{Cite web |title=Model 25-IS Series |url=https://ludlums.com/products/all-products/product/model-25-is-series |access-date=2025-04-10 |website=ludlums.com}}
| |{{Flag|Texas}}, United States |76x54x17 |144 |2 lithium button cells |LCD with backlight |{{Yes}} |{{No}} |0.09 —87.6e5 |10 —99.9e7 | |{{Yes|Yes (60 keV — 2 MeV)}} | | |
Ludlum Model 25-IS-1
| |{{Flag|Texas}}, United States |76x54x17 |144 |2 lithium button cells |LCD with backlight |{{Yes}} |{{No}} |1 — 99.9e5 |114 — 11.4e8 | |{{Yes|Yes (60 keV — 2 MeV)}} | | |
----
| |{{flag|Mainland China}} |120x78x27 | |1100mAh Lithium-ion battery |LCD with backlight |{{yes}} |{{yes}} |0.01 — 50e3 |1 — 50e5 | |{{partial|combined, 48 keV - 1.5 Mev ≤ ±30%}} | |Hydrogen Cyanide Detector |
----
| |{{flag|Mainland China}} | | |850 mAh Lithium-ion battery |LCD with backlight |{{yes}} | | | | |{{yes}} | | |
----
|Radiascan 501Imported from Russian Wikipedia: Индивидуальные_дозиметрыImported from Ukrainian Wikipedia: Порівняння дозиметрів і радіометрів | |{{flag|Russia}} |110х60х23 |110 |2 AAA battery |Color OLED display |{{yes}} |{{no}} |Geiger–Müller tube Beta 1-1 |0.01—10e3 |1—10e5 |1 — 60 |{{no}} |{{yes}} |food contamination tester, "background pattern analysis algorithm"{{efn|{{langx|ru|оценка фона по заданному расписанию|lit=background assessment according to a specified schedule}}}} |
----
|SA-05A[http://www.allimann.com/shop/index.php?id_product=8&controller=product&id_lang=4 Allimann.com] |{{flag|Switzerland}} |119x65x26.5 |135 |Built-in lithium polymer battery |LCD |{{no}} |{{no}} |Geiger–Müller tube LND 713 |0.01–6000 |{{no}} |1 – 60 |{{Partial|0.05–1.3 MeV}} |{{yes|USB}} |Clock, calendar and data logger |
----
|48px |{{flag|Russia}} |110х60х23 |110 |2 AAA battery |Color OLED display |{{yes}} |{{no}} |Geiger–Müller tube Beta 1-1 |0.01—10e3 |1—10e5 |1 — 60 |{{partial|Combined}} |{{yes|USB}} |food contamination tester |
----
|ANRI 01-02 Sosna[https://ntfprompribor.ru/page221497 Дозиметр-радиометр АНРИ-01-02 "Сосна"] |{{flag|Russia}} |133x82x45 |350 |LCD |{{yes}} |{{no}} |Two to four Geiger–Müller tubes |0.1–100 |10–10e4 |20±5 |{{partial|Combined, 0.5–3.0 MeV}} |{{no}} | |
bGeigie Nano{{Cite web |date=2022-02-24 |title=Features - bGeigieZen |url=https://bgeigiezen.safecast.jp/features/ |url-status=live |archive-url=https://web.archive.org/web/20241202045908/https://bgeigiezen.safecast.jp/features/ |archive-date=2024-12-02 |access-date=2024-12-02 |website=bgeigiezen.safecast.jp |language=en-US}}{{Cite web |title=Specifications |url=https://github.com/Safecast/bGeigieNanoKit/wiki/Specifications |url-status=live |archive-url=https://web.archive.org/web/20241202051208/https://github.com/Safecast/bGeigieNanoKit/wiki/Specifications |archive-date=2024-12-02 |access-date=2024-12-02 |website=GitHub |language=en}}
|File:Safecast bGeigie Nano - closed.jpg |{{Country|Japan}} |149x103x54 |440 |LCD |{{no}} |{{Yes}} |one Geiger–Müller tube |0–1000 |0–100 |1 – 60 |{{Yes}} |USB, Bluetooth, and WiFi |Waterproof,Clock GPS, open-source |
bGeigieZen Standard{{Cite web |date=2023-07-21 |title=bGeigieZen Assembled |url=https://bgeigiezen.safecast.jp/store-2/bgeigiezen-assembled/ |url-status=live |archive-url=https://web.archive.org/web/20241202050213/https://bgeigiezen.safecast.jp/store-2/bgeigiezen-assembled/ |archive-date=2024-12-02 |access-date=2024-12-02 |website=bgeigiezen.safecast.jp |language=en-US}}
|{{Country|Japan}} |165x98x52 |450 |replaceable 18650 3000mA + USB-C +QI wireless |IPS LCD with touchscreen |{{partial|No and yes (app can produce sound)}} |{{no}} |one LND7317 Geiger–Müller tube |0-1000 |0-100 |1 — 60 |{{yes C}} |{{yes|USB, Bluetooth, and WiFi}} |Waterproof,Clock GPS, open-source. WiFi and BLE upload of data. |
bGeigieZen NFW
|{{Country|Japan}} |165x98x52 |450 |replaceable 18650 3000mA + USB-C +QI wireless |IPS LCD with touchscreen |{{partial|No and yes (app can produce sound)}} |{{no}} |one LND7317 Geiger–Müller tube |0-1000 |0-100 |1 — 60 |{{yes C}} |{{yes| USB, Bluetooth, and WiFi}} |Waterproof,Clock GPS, open-source. WiFi and BLE upload of data. |
----
| |{{Flag|Belarus}} |125x42x24 |90 |Two LR44 |LCD |{{yes}} |{{no}} |0.01–2000 |1–2*10e5 | |{{no}} |{{yes|Infrared}} |Clock with alarm |
----
|DKR-04 | | |74х48х16 |50 |AAA |LCD |{{yes}} |{{no}} |Semiconductor |0.1–10e6 |10–10e8 |4 — 256 |{{no}} |{{no}} | |
Ecotest DKG-21M{{Cite web |title=DKG-21M: Personal Gamma Radiation Dosimeter |url=https://ecotestgroup.com/products/dkg-21m/ |access-date=2025-05-05 |website=Ecotest}}
| |{{Flag|Ukraine}} |98×58×18 |140 | |{{Yes}} | |0.1 – 10e5 ±15% | | |{{Yes|Yes (0.05 – 6 MeV)}} |infrared | |
Ecotest DKG-24 "PRD Guarder"{{Cite web |title=PRD GUARDER: Personal radiation dosimeter DKG-24 |url=https://ecotestgroup.com/products/prd-guarder/ |access-date=2025-05-05 |website=Ecotest}}
| |{{Flag|Ukraine}} |60×110×30 |250 |2 АА |backlit monochrome display |{{Yes}} |{{Yes}} |CsI(Tl) scintillator, silicon semiconductor |0.01 – 107 | |10 – 90 |{{Yes|Yes (0.02 – 10.0 MeV)}} |gyroscope, GPS |
Ecotest MKS-03D "Swift"
|{{Flag|Ukraine}} |111x73x28 |200 |2 АА |LCD with backlight |{{Yes}} |{{Yes}} |0.1—105 |10—107 |4 — 128 |{{Partial|Combined, 0.12—3.0 MeV Beta measurement range 5—105 min−1 cm−2}} |{{Yes|USB}} |Clock with alarm, optional case |
----
|Ecotest MKS-05 "Terra-P" |{{Flag|Ukraine}} |120×52×26 |150 |Two AAA |LCD |{{yes}} |{{no}} |0.1–1000 |10–10e5 |5 — 70 |{{partial|Combined, 0.5–3.0 MeV}} |{{no}} |Clock with alarm, cover as option |
----
|Ecotest MKS-05 "Terra" (New edition) | |{{Flag|Ukraine}} |120×52×26 |150 |Two AAA |LCD with backlight |{{yes}} |{{yes}} |0.1–10e4 |10–10e6 |1 — 70 |{{partial|Combined, 0.5–3.0 MeV}} |{{yes|Bluetooth}} |Clock with alarm, cover |
Ecotest MKS-05 "Terra" (with Bluetooth channel){{Cite web |title=TERRA with Bluetooth channel: Dosimeter-Radiometer МКS-05 |url=https://ecotestgroup.com/products/terra-with-bluetooth-channel |access-date=2025-05-05 |website=Ecotest}}
| |{{Flag|Ukraine}} |120×52×26 |150 |Two AAA |LCD with backlight | | | | | | | | | |
Ecotest MKS-UM
| |{{Flag|Ukraine}} |166×70×132 (control unit), 47×95×173 (probe) |70 (control unit), 30 (probe) | | |{{Yes}} | |1 – 10e6 | | |{{Yes|Yes (0.05 – 3 MeV)}} | | |
Ecotest RKS-01 "STORA-TU"
| |{{Flag|Ukraine}} |160×75×36 |50 |Two AAA | |{{Yes}} | |0.1 – 999.9 | | | |{{Yes|Bluetooth}} | |
GQ GMC-300E +V4{{cite web |title=GQ Geiger Counter Selection Guide |url=https://www.gqelectronicsllc.com/support/GMC_Selection_Guide.htm |accessdate=2022-10-06 |work=GQ Electronics LLC}}
|File:Zaporizhzhia geigercounter IMG 7309 (53022159432).jpg |{{Flag|Washington|name=Washington}}, United States | | |AA |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |One Geiger–Müller tube |328 |32.8 |1 — 60 |Combined|Combined |{{yes|USB}} | |
GQ GMC-320 +V4
| |{{Flag|Washington|name=Washington}}, United States | | |AA |LCD with backlight|LCD with backlight |{{yes}} |{{No}} |One Geiger–Müller tube |328 | Combined |32.8 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |gyroscope, temperature sensor |
GQ GMC-320 +V5
| |{{Flag|Washington|name=Washington}}, United States | | |AA |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |One Geiger–Müller tube |328 |32.8 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |WiFi, logging to a server, gyroscope, temperature sensor |
GQ GMC-300S
|{{Flag|Washington|name=Washington}}, United States | | |AA |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |One Geiger–Müller tube |1000 |100 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} | |
GQ GMC-320S
| |{{Flag|Washington|name=Washington}}, United States | | |AA |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |One Geiger–Müller tube |1000 |100 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |gyroscope, temperature sensor |
GQ GMC-SE
| |{{Flag|Washington|name=Washington}}, United States | | |AA |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |One Geiger–Müller tube |2000 |200 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} | |
GQ GMC-500
| |{{Flag|Washington|name=Washington}}, United States | | |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |One Geiger–Müller tube |5000 |500 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |WiFi, logging to a server, gyroscope |
GQ GMC-500+
|{{Flag|Washington|name=Washington}}, United States |135x78x25 | |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |Two Geiger–Müller tubes |0 – 42.5e3 | 1–60 |0 – 4.25e6 |1 – 60 |Combined |{{yes|USB}} |WiFi, logging to a server, gyroscope |
GQ GMC-800
| |{{Flag|Washington|name=Washington}}, United States | | |AA |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |One Geiger–Müller tube |2000 |200 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} | |
GQ GMC-600
| |{{Flag|Washington|name=Washington}}, United States | | |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |SBT-11 |4250 |425 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |WiFi, logging to a server, gyroscope |
GQ GMC-600+
| |{{Flag|Washington|name=Washington}}, United States | | |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |LND 7317 |10e3 |1000 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |WiFi, logging to a server, gyroscope |
GQ GMC-510
| |{{Flag|Washington|name=Washington}}, United States | | |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |M4011 |4250 |425 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |WiFi, logging to a server, gyroscope |
GQ GMC-520
| |{{Flag|Washington|name=Washington}}, United States | | |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |M4011 |4250 |425 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |WiFi, logging to a server, gyroscope |
GQ GMC-520+
| |{{Flag|Washington|name=Washington}}, United States | | |LCD with backlight|LCD with backlight |{{yes}} |{{no}} |M4011 |4250 |425 | Combined |1 – 60 |Combined|Combined |{{yes|USB}} |WiFi, logging to a server, gyroscope |
---- GQ Geiger Counter - GMC-500 Plus 1.jpg
|{{flag|Russia}} |105х60х26 |90 |One or two AAA |LCD with backlight |{{yes}} |{{partial|Only RD1503+}} |0.05 – 10 |5 – 1000 |up to 40 |{{partial|Combined, 0.1–1,25 MeV}} |{{no}} | |
----
|{{flag|Russia}} |105х60х26 |90 |One or two AAA |LCD with backlight |{{yes}} |{{yes}} |Two Geiger–Müller tubes |0.05 –1000 |5 – 10e5 |1 – 26 |{{partial|Combined, 0.1–1.25 MeV}} |{{no}} |Background mode |
----
| |{{flag|Russia}} |97x68x24 |80 |One or two AAA |LCD with backlight |{{yes}} |{{yes}} |One Geiger–Müller tube |0.05 – 999 |5 – 10e5 |1 – 10 |{{partial|Combined, 0.4–3.5 MeV}} |{{yes|USB}} |Background mode, integrated flashlight, time and date functions, multilingual |
----
|{{flag|Russia}} |140х64х26 |175 |AA |LCD with backlight |{{yes}} |{{yes}} |Two Geiger–Müller tubes |0.1 – 1000 |2 – 120 |2 – 21 |{{yes|Separated, 0.05–3.5 MeV}} |{{no}} |Background mode, separated indication of beta and gamma radiation |
RadiaCode 102{{Cite web |title=Radiacode 1ox series |url=https://www.radiacode.com/ |url-status=live |archive-url=https://web.archive.org/web/20241127205759/https://www.radiacode.com/ |archive-date=2024-11-27 |access-date=2024-11-27 |website=Radiacode |language=en-US}}{{Cite web |last=Kolotukhin |first=Igor |title=Quick Guide Manual |url=https://coda.io/d/radiacode-cyberspace_dTtFtorf-v-/Quick-Guide-Manual_suS3AbP_#_lu5Ub3i4 |url-status=live |archive-url=https://web.archive.org/web/20241127205952/https://coda.io/d/radiacode-cyberspace_dTtFtorf-v-/Quick-Guide-Manual_suS3AbP_#_lu5Ub3i4 |archive-date=2024-11-27 |access-date=2024-11-27 |website=radiacode cyberspace |publisher=Radiacode |language=en-US |via=Coda}}{{Cite web |title=Detector of nuclear radiation and spectrometer Radiacode 102: SKU RC102 |url=https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-102/p/601830018 |url-status=live |archive-url=https://web.archive.org/web/20241127210651/https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-102/p/601830018 |archive-date=2024-11-27 |access-date=2024-11-27 |website=Radiacode |language=en-US}}
|{{Flag|Republic of Cyprus}} |conflicting answers (124x35x20 or 123x34x18) |65 |built-in Lithium polymer battery |LCD with backlight |{{yes}} | |CsI(Tl) scintillator |0.01 – 1000 |1 — 10e5 |0.5 |yes |thermometer, clock |
RadiaCode 103{{Cite web |title=Detector of nuclear radiation and spectrometer Radiacode 103G: SKU RC103 |url=https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-103/p/602724693 |url-status=live |archive-url=https://web.archive.org/web/20241127210651/https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-102/p/601830018 |archive-date=2024-11-27 |access-date=2024-11-27 |website=Radiacode |language=en-US}}
| |{{Flag|Republic of Cyprus}} |conflicting answers (124x35x20 or 123x34x18) |65 |built-in Lithium polymer battery |LCD with backlight |{{yes}} | |CsI(Tl) scintillator |0.01 – 1000 |1 — 10e5 |0.5 |yes |thermometer, clock |
RadiaCode 103G{{Cite web |title=Detector of nuclear radiation and spectrometer Radiacode 103G: SKU RC103G |url=https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-103G/p/640576121 |url-status=live |archive-url=https://web.archive.org/web/20241127210651/https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-102/p/601830018 |archive-date=2024-11-27 |access-date=2024-11-27 |website=Radiacode |language=en-US}}
| |{{Flag|Republic of Cyprus}} |conflicting answers (124x35x20 or 123x34x18) |70 |built-in Lithium polymer battery |LCD with backlight |{{yes}} | |GAGG(Ce) Scintillator |0.01 – 1000 |1 — 10e5 |0.5 |yes |thermometer, clock |
RadTarge II D300{{cite news|url=https://www.x-zlab.com/product/radtargeii-d300-electronic-personal-dosimeter/|title=Electronic Personal Dosimeter {{!}} RadTarge II D300 {{!}} X-Z LAB|newspaper=X-Z LAB|language=en-US|access-date=2016-11-14}}
| |{{Flag|Mainland China}} |69x46x17 |60 |Built-in lithium ion battery |LCD with backlight |{{yes}} |{{yes}} |YSO scintillator + SiPM |0.5 – 5000 |50 – 5e5 |< 8 |{{no|No, 0.03–1.5 MeV}} |{{yes|USB}} |Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) |
RadTarge II D700{{cite news|url=https://www.x-zlab.com/product/radtargeii-d700-electronic-personal-dosimeter/|title=Electronic Personal Dosimeter {{!}} RadTarge II D700 {{!}} X-Z LAB|newspaper=X-Z LAB|language=en-US|access-date=2016-11-14}}
| |{{Flag|Mainland China}} |69x46x17 |60 |Built-in lithium-ion battery |LCD with backlight |{{yes}} |{{yes}} |YSO scintillator + SiPM |0.01 — 1000 |1 — 10e5 |< 2 |{{no|No, 0.02–3 MeV}} |{{yes|USB}} |Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) |
RadTarge II D900{{cite news|url=https://www.x-zlab.com/product/radtargeii-d900-electronic-personal-dosimeter/|title=Electronic Personal Dosimeter {{!}} RadTarge II D900 {{!}} X-Z LAB|newspaper=X-Z LAB|language=en-US|access-date=2016-11-14}}
| |{{Flag|Mainland China}} |69x46x17 |60 |Built-in lithium-ion battery |LCD with backlight |{{yes}} |{{yes}} |YSO scintillator + SiPM |0.1 – 10e5 |10 – 10e7 |< 6 |{{no|No, 0.02–3 MeV}} |{{yes|USB}} |Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) |
----
| |{{Flag|Belarus}} |154х77х39 |350 |LCD |{{no}} |{{no}} |Two Geiger–Müller tubes |0.1 — 100 |10 — 2e4 |18 – 400 |{{partial|Combined, 0.5–3.0 MeV}} |{{no}} | |
RKS-107
|{{Flag|Belarus}} |154x77x39 |350 |LCD |{{No}} |{{No}} |0.1 — 99.99 |10 — 9999 | | | | |
Pripyat RKS-20.03{{Cite web |title=Rukovodstvo po ekspluatatsii radiometra RKS-20.03 "Pripyat" |script-title=uk:Руководство по эксплуатации радиометра РКС-20.03 "Припять" |trans-title=Operation manual for the RKS-20.03 "Pripyat" radiometer |url=https://sorbpolimer.com.ua/uploads/rks-20_03-manual.pdf |url-status=live}}
|{{Flag|Ukraine}} | | | | | | |Two SBM-20 Geiger–Müller tubes | | | | | | |
----
| |{{Flag|Belarus}} |58х58х18 |70 |Built-in accumulator |LCD |{{yes}} |{{yes}} |One Geiger–Müller tube |0.01 — 1.2e6 |1 — 1.2e8 | |{{no}} |{{yes|USB}} |Shock protection |
----
|EcotestCARD{{Efn|Named as Экотест ДКГ-21}} | |{{Flag|Ukraine}} | |80 |LCD |{{yes}} |{{no}} |Semiconductor |0.1–10e6 |10–10e8 | | |{{yes|Infrared}} | |
SOEKS 01M
|{{flag|Russia}} | | | | | | | | | | | | |
---- |
Notes
{{Notelist}}
References
{{Reflist}}
Literature
- {{cite web |work=International Atomic Energy Agency |year=2007 |title=Intercomparison of personal dose equivalent measurements by active personal dosimeters |location=Chicago |url=https://www-pub.iaea.org/MTCD/Publications/PDF/te_1564_web.pdf}}
- {{cite journal |vauthors=Bordy JM, Daures J, Clairand I, Denozière M, Donadille L, d'Errico F, Gouriou J, Itié C, Struelens L |year=2008 |title=Evaluation of the calibration procedure of active personal dosemeters for interventional radiology |journal=Radiation Protection Dosimetry |volume=131 |issue=1 |pages=87–92 |doi=10.1093/rpd/ncn225 |pmid=18757898}}
- {{cite web |title=Comparison of Personal Dosimeters |work=Radiation Emergency Medical Management (REMM) |url=https://remm.hhs.gov/dosimeter_marketsurvey.htm |publisher=United States Department of Health and Human Services |accessdate=October 10, 2022}}