Contax G
{{Infobox camera
| camera_name = Contax G
| image = File:Contax G1 0525.jpgFile:Contax G2 - 1 (2835008157).jpg
| type = 35 mm rangefinder camera
| lens_mount = Contax G-mount
| focus = AF
| exposure = auto
| flash = hot shoe
| frame-rate =
| dimensions =
}}
The Contax G camera line consists of two cameras, the G1 and G2, interchangeable-lens cameras sold by Kyocera under the Contax brand in competition with the Leica M7, Cosina Voigtländer Bessa-R, and Konica Hexar RF. The G1 was introduced in 1994 with the G2 joining it in 1996. In 2005, Kyocera retreated from the camera business and announced it would cease all activity related to the manufacture of Contax cameras at the end of the year, effectively spelling the end of the G system.{{cite press release |url=http://global.kyocera.com/news/2005/0402.html |title=CONTAX-Branded Camera Business |date=April 12, 2005 |publisher=Kyocera Global |archiveurl=https://web.archive.org/web/20050413030214/http://global.kyocera.com/news/2005/0402.html |archivedate=13 April 2005 |url-status=dead |access-date=17 November 2018 }}
Design
The two G-series cameras have titanium-clad bodies and use the Contax G-mount, an electromechanical autofocus mount.{{cite magazine |url=https://books.google.com/books?id=Nx8_7xbot7cC&pg=PA62 |title=Test: Contax G1 |date=April 1995 |magazine=Popular Photography |pages=62–68;73;158 |accessdate=15 November 2018}} When tested in 1995, the Contax G1 cost {{USD|2210|1995|round=-2}} with the 45 mm Planar lens; the 28 mm Biogon and 90 mm Sonnar lenses were each {{USD|660|1995|round=-1}}, and the list price for the 16 mm Hologon was {{USD|3000|1995|round=-2}}. The 45 mm Planar was listed separately at {{USD|420|1995|round=-1}}.{{cite magazine |url=https://books.google.com/books?id=Nx8_7xbot7cC&pg=PA69 |title=Test: Carl Zeiss T* Lenses |date=April 1995 |magazine=Popular Photography |pages=69;170 |accessdate=15 November 2018}} The Contax G2 listed for {{USD|2250|1999|round=-2}} with the 45 mm Planar lens in 1999.{{cite magazine |url=https://books.google.com/books?id=yNijOBJattoC&pg=PA135 |title=Contax G2 |date=December 1999 |magazine=Popular Photography |page=135 |accessdate=15 November 2018}}
Critics were quick to accuse the G1 of not being a "true" (mechanical) rangefinder, since it used autofocus and electronically linked mechanisms.{{Citation needed|date=October 2007}} However, the AF mechanism in the G-series does indeed use a twin-window system much like that of the older mechanical rangefinders — only in electronic form. The viewfinder covers the field of view for lenses of focal lengths between 28 and 90 mm through an optical zoom, and automatically compensates for parallax error and field when focusing closer. The in-body finder shows 90% of the captured frame at 0.59× magnification when the "normal" 45 mm lens is used.{{cite magazine |url=https://books.google.com/books?id=yUCq55hT0RoC&pg=PA22 |title=First Look: New Contax G1 |date=November 1994 |magazine=Popular Photography |pages=26;30;186 |accessdate=15 November 2018}} The viewfinder uses molded aspherical lens elements to reduce size.
While there is an electronic connection between camera and lens to transmit data, the lenses have no AF motor and no means to adjust focus on the lens itself; both autofocus and manual focus are driven by a motor in the camera through a mechanical "screwdriver" coupling. The focus dial on the G1 is the dial marked with distances on the far right side of the body, and is also used to select the autofocus mode; on the G2, the focus dial was separated from the focus mode control and moved to the top front edge of the body.
=Contax G2=
File:Carl Zeiss Contax G Sonnar 2.8 90 T* black.jpg
Compared with the original G1, the G2 has improved autofocus performance and higher top shutter speeds of {{frac|4000}} sec in manual mode and {{frac|6000}} sec in aperture priority mode. The manual focus wheel was moved from the top deck to the front, to about the same position as where the focusing wheel was located on classic Dresden and Stuttgart Contax rangefinders.{{cite magazine |url=https://books.google.com/books?id=_lM3mdMJNHIC&pg=PA42 |title=Contax G2: More Is More! |date=October 1996 |magazine=Popular Photography |pages=42 |accessdate=15 November 2018}} In addition, the G2 was made available in a black finish along with black versions of the TLA200 flash and 28 mm, 45 mm, and 90 mm lenses.{{cite web |url=http://www.contaxcameras.com/gseries/g2black.html |title=Contax G2 Black |date=1997 |website=Contax Cameras |archiveurl=https://web.archive.org/web/19981206084202/http://www.contaxcameras.com/gseries/g2black.html |archivedate=6 December 1998 |url-status=dead |access-date=17 November 2018 }}
A new active auto-focus system has been added to the G2, which uses near-infrared beams to set the range. The G2 auto-focus also has two focusing modes: continuous, which constantly adjusts focus as the camera is moved; and single, which is a safety mode, focussing as the focus button is pressed (or shutter release half-pressed), and maintaining this reading until the shutter is released. If the camera fails to find focus in this mode, the shutter cannot be released.
class="wikitable" style="font-size:90%;text-align:center;"
|+style="font-size:111%;" | Comparison of selected parameters, Contax G1 and G2 |
colspan=2 style="width:20%;" | Parameter
! style="width:40%;" | Contax G1 ! style="width:40%;" | Contax G2 |
---|
rowspan=3 | Shutter speeds
! AE | 16–{{frac|2000}} sec | 16–{{frac|6000}} sec |
Manual
| 1–{{frac|2000}} sec, B, X | 4–{{frac|4000}} sec, B, X |
Sync
| {{frac|100}} | {{frac|200}} |
rowspan=2 | Metering
! Internal | colspan=2 | SPD off shutter curtain |
External
| EV 5-19 at ISO 100 (for Hologon) | EV 3-19 at ISO 100 (for Hologon) |
colspan=2 | Exposure modes
| colspan=2 | Aperture priority, Manual, TTL flash, Manual flash |
colspan=2 | Dimensions (W×H×D)
| {{convert|133|×|76.5|×|35|mm|abbr=on|disp=br}} | {{convert|139|×|80|×|45|mm|abbr=on|disp=br}} |
colspan=2 | Weight
| {{convert|450|g|oz|abbr=on}} | {{convert|560|g|oz|abbr=on}} |
colspan=2 | References
| {{cite web |url=http://www.kyoceraimaging.com:80/docs/202000_brochure01.pdf |title=Contax G2 (brochure) |date=1998 |publisher=Kyocera Imaging |archiveurl=https://web.archive.org/web/20040608205715/http://www.kyoceraimaging.com/docs/202000_brochure01.pdf |archivedate=8 June 2004 |url-status=dead |access-date=9 July 2019 }} |
Lenses
The lenses designed by Carl Zeiss for the G-series quickly established it as a camera of worth: the original trio of lenses released with the G1 included the 45 mm {{f/}}2 Planar, 28 mm {{f/}}2.8 Biogon, and 90 mm {{f/}}2.8 Sonnar; the 16 mm {{f/}}8 Hologon was announced at the system launch but was not immediately available. The G2 was released in 1996 alongside the 21 mm {{f/}}2.8 Biogon and 35 mm {{f/}}2 Planar. The 35–70 mm {{f/}}3.5–5.6 Vario-Sonnar, the first zoom lens for a rangefinder camera, was the last lens to be released, in 2000.{{cite magazine |url=https://books.google.com/books?id=k_pGPoSK8NwC&pg=PA84 |title=Lenses |date=July–August 2000 |magazine=American Photo |accessdate=16 November 2018}} All lenses were autofocus with the exception of the Hologon 8/16mm.
File:Contax G Series Lens Mount.jpg
The flange distance between the front surface of the lens mount and the film plane is only {{convert|29|mm}}, and Contax released the GA-1 adaptor which allowed the use of Contax/Yashica mount lenses. Unlike most bayonet-mount lenses, the Contax G mount uses a breech-lock mechanism similar to the manual-focus Canon FD and FL mount.
The very high optical quality of the G-series lenses makes them excellent candidates for use with high-resolution digital sensors. Adapters are available for the Sony E-mount and Micro Four Thirds digital camera.
File:Contax g2 with biogon f2,8 21mm.jpg
Early versions of the G1 could only accept the four original lenses (16 mm, 28 mm, 45 mm, and 90 mm). A modified ROM was required to use autofocus with the 21 mm and 35 mm lenses;{{cite magazine |url=https://books.google.com/books?id=ZLGriUF87fIC&pg=PT1 |title=second coming |author=Hart, Russell |date=January–February 1997 |magazine=American Photo |accessdate=16 November 2018}} modified G1 cameras are marked with a green sticker inside the film door, and are known as "green label" G1s to distinguish them from unmodified "silver label" G1s.{{cite web |url=https://www.theanalogstory.com/tips-and-techniques/2017/6/22/contax-g1-for-travel-and-its-accessories |title=Learning More About the Contax G1 35mm Camera |author=Story, Derrick |date=June 22, 2017 |website=the Analog story |accessdate=16 November 2018 |archive-url=https://web.archive.org/web/20181117151230/https://www.theanalogstory.com/tips-and-techniques/2017/6/22/contax-g1-for-travel-and-its-accessories |archive-date=17 November 2018 |url-status=dead }} No G1 could accept the 35–70 mm, as it was a seven contact electrical connection and the G1 only features five contacts.
Because the viewfinder was limited to the angle of view corresponding to the 28 mm Biogon, the 16 mm Hologon and 21 mm Biogon lenses were each bundled with a separate accessory viewfinder that mounted in the hotshoe.
{{clear}}
class="wikitable sortable" style="font-size:80%;text-align:center;"
|+ style="font-size:125%;" | Contax G lenses | ||||
rowspan=2 colspan=2 data-sort-type="text" | Name
! rowspan=2 data-sort-type="number" | Focal length ! rowspan=2 data-sort-type="number" | Aperture ! colspan=3 | Angle of view ! rowspan=2 data-sort-type="number" | Catalog ! rowspan=2 data-sort-type="number" | Rel. ! colspan=2 | Design ! rowspan=2 data-sort-type="number" | Min focus ! rowspan=2 data-sort-type="number" | Filter ! rowspan=2 data-sort-type="text" | Hood ! colspan=2 | Size ! rowspan=2 data-sort-type="number" | Weight ! rowspan=2 class="unsortable" | Refs. | ||||
---|---|---|---|---|
data-sort-type="number" | H{{efn|Horizontal field of view, i.e., along the 36 mm side of the frame}} | data-sort-type="number" | V{{efn|Vertical field of view, i.e., along the 24 mm side of the frame}} | data-sort-type="number" | D{{efn|Diagonal field of view, i.e., along the diagonal of the film frame}}
! data-sort-type="number" | E{{efn|Number of lens elements}} | data-sort-type="number" | G{{efn|Number of cemented groups}}
! data-sort-type="number" | Φ{{efn|Maximum diameter}} | data-sort-type="number" | L{{efn|Length, measured as projection from mount.}} |
colspan=2 | Hologon{{efn|name=finder|Requires external viewfinder.}}{{efn|Supplied with radially-graduated neutral density filter to ensure even exposure across the frame.}}
| 16 mm{{efn|Zeiss states the focal length of this lens is 16.5 mm.}} | data-sort-value="8" | {{f/}}8 (fixed) | 95° || 72° || 106° | 10 49 27 | 1994 | 5 || 3 | {{convert|0.3|m|ft|abbr=on}} | — | — | {{convert|53|mm|abbr=on}} | {{convert|11|mm|abbr=on}} | {{convert|120|g|abbr=on}} | ||||
colspan=2 | Biogon{{efn|name=finder}}
| 21 mm{{efn|Zeiss states the focal length of this lens is 21.5 mm.}} | data-sort-value="2.8" | {{f/}}2.8−22 | 80° || 59° || 90° | 10 49 37 | 1996 | 9 || 7 | {{convert|0.5|m|ft|abbr=on}} | 55mm | — | {{convert|59|mm|abbr=on}} | {{convert|35|mm|abbr=on}} | {{convert|200|g|abbr=on}} | ||||
colspan=2 | Biogon
| 28 mm{{efn|Zeiss states the focal length of this lens is 28.5 mm.}} | data-sort-value="2.8" | {{f/}}2.8−22 | 65° || 46° || 74° | 10 49 29 | 1994 | 7 || 5 | {{convert|0.5|m|ft|abbr=on}} | 46mm | GG-1 | {{convert|56|mm|abbr=on}} | {{convert|31|mm|abbr=on}} | {{convert|150|g|abbr=on}} | ||||
colspan=2 | Planar
| 35 mm{{efn|Zeiss states the focal length of this lens is 35.1 mm.}} | data-sort-value="2" | {{f/}}2.0−16 | 55° || 38° || 64° | 10 22 14 | 1996 | 7 || 5 | {{convert|0.5|m|ft|abbr=on}} | 46mm | GG-1 | {{convert|56|mm|abbr=on}} | {{convert|29|mm|abbr=on}} | {{convert|160|g|abbr=on}} | ||||
colspan=2 | Planar
| 45 mm{{efn|Zeiss states the focal length of this lens is 46.9 mm.}} | data-sort-value="2" | {{f/}}2.0−16 | 42° || 29° || 50° | 10 22 09 | 1994 | 6 || 4 | {{convert|0.5|m|ft|abbr=on}} | 46mm | GG-2 | {{convert|56|mm|abbr=on}} | {{convert|39|mm|abbr=on}} | {{convert|190|g|abbr=on}} | ||||
colspan=2 | Sonnar
| 90 mm | data-sort-value="2.8" | {{f/}}2.8−22 | 23° || 15° || 27° | 10 11 31 | 1994 | 5 || 4 | {{convert|1.0|m|ft|abbr=on}} | 46mm | GG-3 | {{convert|56|mm|abbr=on}} | {{convert|63|mm|abbr=on}} | {{convert|240|g|abbr=on}} | ||||
rowspan=2 | Vario-Sonnar
| W | rowspan=2 | 35−70 mm{{efn|Zeiss states the focal length range is between 36.5 mm and 68.2 mm.}} | data-sort-value="3.5" | {{f/}}3.5−22 | 53° || 36° || 62° | rowspan=2 | 10 47 65 | rowspan=2 | 2000 | rowspan=2 | 13 | rowspan=2 | 8 | rowspan=2 | {{convert|1.0|m|ft|abbr=on}} | rowspan=2 | 46mm | rowspan=2 | GG-1 | rowspan=2 | {{convert|59|mm|abbr=on}} | rowspan=2 | {{convert|54|mm|abbr=on}} | rowspan=2 | {{convert|290|g|abbr=on}} | ||||
T
| data-sort-value="5.6" | {{f/}}5.6−22 | 29° | 20° | 35° |
;Notes
{{notelist|25em}}
Accessories
File:Contax G2D (5444686347).jpg
Contax marketed a line of accessories dedicated for the G series of cameras and lenses.{{cite web |url=http://www.contaxcameras.com/gseries/accbody.html |title=Contax G Accessories |date=1999 |publisher=Kyocera Imaging |archiveurl=https://web.archive.org/web/20010215012950/http://www.contaxcameras.com/gseries/accbody.html |archivedate=15 February 2001 |url-status=dead |access-date=17 November 2018 }}
;Backs
- GD-1 - For the G1. Limited to date and time imprinting in frame.
- GD-2 - For the G2. Information (date, time, exposure) imprinted between frames, or collected and printed on first two frames. Exposure information includes compensation, shutter speed, approximate aperture, and exposure mode. Also provides intervalometer functions.
;Caps
- GK-41 - Front lens cap, Φ=46mm
- GK-51 - Front lens cap, Φ=55mm for 2.8/21
- GK-54 - Front hood cap, Φ=57mm to push on the front of a mounted hood
- GK-B - Body cap
- GK-R1 - Rear lens cap
- GK-R2 - Rear lens cap, deep for 2.8/28, 2.8/21, 8/16
;Cases
- GC-11 - For the G1.
- GC-112 - Front/top portion of G1 case with 2.8/90 Sonnar.
- GC-21 - For the G2.
- GC-22 - For the G2 with GD-2 data back.
- GC-210 - Front/top portion of G2 case with 2/45 Planar or shorter.
- GC-212 - Front/top portion of G2 case with 2.8/90 Sonnar.
File:CONTAX G2 (8392815210).jpg
;Filters
Available in both 46mm and 55mm sizes.
- P - Protective filter
- UV - UV filter (L37)
- 1A - Skylight
- A2 - Warming (81A)
- B2 - Cooling (82B)
;Flash
- TLA 140 - Introduced with G1.
- TLA 200 - Introduced with G2. Zoom reflector marked at 28mm, 35mm, 45mm, and 90mm coverage settings.
{{clear}}
class="wikitable sortable" style="font-size:100%;text-align:center;"
|+Comparison of TLA 140 and TLA 200 flash units |
Name
! Guide number ! Battery ! Recycle time ! Endurance ! Dimensions (W×H×D) ! Weight |
---|
TLA 140
| 14m (ISO 100) | 1×CR123A | 4.8 sec | approx. 200 | {{convert|57|×|74|×|20.5|mm|abbr=on|disp=br()}} | {{convert|80|g|abbr=on}} |
TLA 200
| 20m (ISO 100) | 2×CR2 | 3.5 sec | approx. 200 | {{convert|61|×|51|×|47|mm|abbr=on|disp=br()}} | {{convert|90|g|abbr=on}} |
;Hoods
- GG-1 - For the 2.8/28 Biogon, 2/35 Planar, and 3.5-5.6/35-70 Vario-Sonnar
- GG-2 - For the 2/45 Planar
- GG-3 - For the 2.8/90 Sonnar
;Mount Adapter
- GA-1 - Allows the use of certain Contax/Yashica mount lenses (focal length of adapted lens is selectable on adapter: 28, 35, 50, 60, or 85mm). Rangefinder on body used to determine distance, then lens is focused manually.
;Power
- GP-1 - Power pack adapter, fits in body and provides a terminal for the P-8 power pack
- P-8 - Power pack, external battery pack
;Viewfinders
- GF-16mm - For the 8/16 Hologon
- GF-21mm - For the 2.8/21 Biogon
Gallery
References
{{reflist}}
External links
{{Commons}}
- [http://www.allans-stuff.com/contaxg1.html Contax G1 FAQ]
- {{cite web |url=http://www.kyoceraimaging.com:80/docs/202000_brochure01.pdf |title=Contax G2 (brochure) |date=1998 |publisher=Kyocera Imaging |archiveurl=https://web.archive.org/web/20040608205715/http://www.kyoceraimaging.com/docs/202000_brochure01.pdf |archivedate=8 June 2004 |url-status=dead |access-date=9 July 2019 }}
{{Kyocera}}