Dichlorodifluoromethane
{{chembox
| Verifiedfields = changed
| Watchedfields = changed
| verifiedrevid = 442842661
| Name =
| ImageFile =
| ImageFileL1 = Dichlorodifluoromethane.png
| ImageSizeL1 =
| ImageFileR1 = Dichlorodifluoromethane-3D-vdW.png
| ImageSizeR1 =
| PIN = Dichlorodi(fluoro)methane
| SystematicName =
| OtherNames = {{Unbulleted list|Dichlorodifluoromethane|Carbon dichloride difluoride|Dichloro-difluoro-methane|Difluorodichloromethane|Freon 12|R-12|CFC-12|P-12|Propellant 12|Halon 122|Arcton 6|Arcton 12|E940|Fluorocarbon 12|Genetron 12|Refrigerant 12}}
| IUPACName =
| Section1 = {{Chembox Identifiers
| ChemSpiderID_Ref = {{chemspidercite|correct|chemspider}}
| ChemSpiderID = 6151
| ChEMBL_Ref = {{ebicite|changed|EBI}}
| ChEMBL = 2106634
| UNII_Ref = {{fdacite|correct|FDA}}
| UNII = OFM06SG1KO
| InChIKey = PXBRQCKWGAHEHS-UHFFFAOYAX
| StdInChI_Ref = {{stdinchicite|correct|chemspider}}
| StdInChI = 1S/CCl2F2/c2-1(3,4)5
| StdInChIKey_Ref = {{stdinchicite|correct|chemspider}}
| StdInChIKey = PXBRQCKWGAHEHS-UHFFFAOYSA-N
| CASNo = 75-71-8
| CASNo_Ref = {{cascite|correct|CAS}}
| EINECS = 200-893-9
| PubChem = 6391
| SMILES = ClC(Cl)(F)F
| InChI = 1/CCl2F2/c2-1(3,4)5
| RTECS = PA8200000
| KEGG_Ref = {{keggcite|correct|kegg}}
| KEGG = D03789
| UNNumber = 1028
}}
| Section2 = {{Chembox Properties
| C=1 | Cl=2 | F=2
| Appearance = Colorless gas
| Odor = ether-like at very high concentrations
| Density = 1.486 g/cm3 ({{convert|-29.8|C}})
| MeltingPtC = −157.7
| BoilingPtC = −29.8
| Solubility = 0.286 g/L at {{convert|20|C}}
| Solvent = alcohol, ether, benzene, acetic acid
| SolubleOther = Soluble
| LogP = 2.16
| VaporPressure = 568 kPa ({{convert|20|C}})
| HenryConstant = 0.0025 mol kg−1 bar−1
| MagSus = −52.2·10−6 cm3/mol
| ThermalConductivity = 0.0097 W/(m·K) (300 K)Touloukian, Y. S., Liley, P. E., and Saxena, S. C. Thermophysical properties of matter – the TPRC data series. Volume 3. Thermal conductivity – nonmetallic liquids and gases. Data book. 1970.
}}
| Section3 = {{Chembox Structure
| MolShape = Tetrahedral
| Dipole = 0.51 DKhristenko, Sergei V.; Maslov, Alexander I. and Viatcheslav P. Shevelko; Molecules and Their Spectroscopic Properties, p. 74 {{ISBN|3642719481}}.
}}
| Section4 = {{Chembox Hazards
| ExternalSDS =
| NFPA-H = 0
| NFPA-F = 0
| NFPA-R = 0
| NFPA-S =
| GHSPictograms = {{GHS07}}
| GHSSignalWord = Warning
| HPhrases = {{H-phrases|336|420}}
| PPhrases = {{P-phrases|261|271|304+340|319|403+233|405|410+403|501|502}}
| FlashPt = Non-flammable
| PEL = TWA 1000 ppm (4950 mg/m3){{PGCH|0192}}
| REL = TWA 1000 ppm (4950 mg/m3)
| LC50 = 760,000 ppm (mouse, 30 min)
800,000 ppm (rabbit, 30 min)
800,000 ppm (guinea pig, 30 min)
600,000 ppm (rat, 2 h){{IDLH|75718|Dichlorodifluoromethane}}
}}
| Section5 =
| Section6 =
}}
Dichlorodifluoromethane (R-12) is a colorless gas popularly known by the genericized brand name Freon (as Freon-12). It is a chlorofluorocarbon halomethane (CFC) used as a refrigerant and aerosol spray propellant. In compliance with the Montreal Protocol, its manufacture was banned in developed countries (non-article 5 countries) in 1996, and in developing countries (Article 5 countries) in 2010 out of concerns about its damaging effect on the ozone layer.{{cite book |title=Scientific assessment of ozone depletion: 2018. |date=2018 |publisher=World Meteorological Organization |location=Geneva, Switzerland |isbn=978-1-7329317-1-8 |page=1.10 |edition=Global Ozone Research and Monitoring Project–Report No. 58 |url=https://www.environment.gov.au/system/files/resources/bde22641-eeb6-4502-9c54-8239c2c64c0f/files/2018-ozone-summary-report.pdf |access-date=22 November 2020 |chapter=1:Update on Ozone-Depleting Substances (ODSs) and Other Gases of Interest to the Montreal Protocol}} Its only allowed usage is as a fire retardant in submarines and aircraft. It is soluble in many organic solvents. R-12 cylinders are colored white.
Preparation
It can be prepared by reacting carbon tetrachloride with hydrogen fluoride in the presence of a catalytic amount of antimony pentachloride:
:CCl4 + 2HF
This reaction can also produce trichlorofluoromethane (CCl3F), chlorotrifluoromethane (CClF3) and tetrafluoromethane (CF4).{{Greenwood&Earnshaw2nd|page=304}}
History
Charles F. Kettering, vice president of General Motors Research Corporation, was seeking a refrigerant replacement that would be colorless, odorless, tasteless, nontoxic, and nonflammable. He assembled a team that included Thomas Midgley Jr., Albert Leon Henne, and Robert McNary. From 1930 to 1935, they developed dichlorodifluoromethane (CCl2F2 or R12), trichlorofluoromethane (CCl3F or R11), chlorodifluoromethane (CHClF2 or R22), trichlorotrifluoroethane (CCl2FCClF2 or R113), and dichlorotetrafluoroethane (CClF2CClF2 or R114), through Kinetic Chemicals which was a joint venture between DuPont and General Motors.{{cite book | title=High Performance Polymers: Their Origin and Development | publisher=Elsevier Science Publishing Co., Inc. | author=Plunkett, Roy J. | year=1986 | pages=261–262 | isbn=978-94-011-7073-4}}
Use as an aerosol
The use of chlorofluorocarbons as aerosols in medicine, such as USP-approved salbutamol, has been phased out by the U.S. Food and Drug Administration. A different propellant known as hydrofluoroalkane, or HFA, which was not known to harm the environment, was chosen to replace it.{{Cite web |url=http://www.pittsburghlive.com/x/pittsburghtrib/news/mostread/s_493084.html |title=Asthma inhaler replacements coming to Pa. - Pittsburgh Tribune-Review |date=16 February 2007 |website= |access-date=26 April 2022 |archive-url=https://web.archive.org/web/20070216044756/http://www.pittsburghlive.com/x/pittsburghtrib/news/mostread/s_493084.html |archive-date=16 February 2007 |url-status=dead}} That being said it still listed on the FDA's approved food additive list.
class="wikitable"
!CAS Reg. No. (or other ID)*: |75-71-8 |
Environmental Effects
R-12 has the highest ozone depletion potential among chlorocarbons due to the presence of 2 chlorine atoms in the molecule.
R-12 also has intense global warming potential (GWP) with the 20yr, 100yr and 500yr GWP being 11400, 11200 and 5100 times greater than {{chem2|CO2}}.{{Cite web | url=https://www.ipcc.ch/report/ar6/wg1/downloads/report/IPCC_AR6_WGI_FGD_Chapter07_SM.pdf| title=IPCC Sixth Assessment Report - The Physical Science Basis - Chapter 7 Supplementary Material Table 7 |access-date=1 November 2024 |archive-url=https://web.archive.org/web/20240630195210/https://www.ipcc.ch/report/ar6/wg1/downloads/report/IPCC_AR6_WGI_FGD_Chapter07_SM.pdf |archive-date=30 June 2024 }}
Retrofitting
R-12 was used in most refrigeration and vehicle air conditioning applications prior to 1994 before being replaced by 1,1,1,2-tetrafluoroethane (R-134a), which has an insignificant ozone depletion potential. Automobile manufacturers began phasing in R-134a around 1993{{CN|date=November 2024}}. When older units leak or require repair involving removal of the refrigerant, retrofitment to a refrigerant other than R-12 (most commonly R-134a) is required in some jurisdictions. The United States does not require such conversion. Retrofitment requires a system flush and a new filter/dryer or accumulator, and may also involve the installation of new seals and/or hoses made of materials compatible with the refrigerant being installed. Mineral oil used with R-12 is not compatible with R-134a. Some oils designed for conversion to R-134a are advertised as compatible with residual R-12 mineral oil. Illegal replacements for R-12 include highly flammable hydrocarbon blends such as HC-12a, the flammability of which has caused injuries and deaths.{{Cite web|url=https://ensegundos.com.pa/2019/10/23/se-cumplen-13-anos-de-la-tragedia-de-la-cresta/|title=Se cumplen 13 años de la Tragedia de la Cresta|website=Ensegundos.com.pa|date=23 October 2019}}{{cite web|url=https://m.metrolibre.com/nacionales/152183-v%C3%ADctimas-de-la-tragedia-de-la-cresta-fueron-recordadas.html|title=Victims of the La Cresta tragedy were remembered|website=M.metrolibra.com|access-date=26 April 2022}}
Dangers
Aside from its environmental impacts, R12, like most chlorofluoroalkanes, forms phosgene gas when exposed to a naked flame.{{cite web |title=False Alarms: The Legacy of Phosgene Gas |url=https://hvacrschool.com/phosgene-gas/ |website=HVAC School |date=4 January 2021 |access-date=9 May 2022}}
Properties
Table of thermal and physical properties of saturated liquid refrigerant 12:{{Cite book |last=Holman |first=Jack P. |title=Heat Transfer |publisher=McGraw-Hill Companies, Inc. |year=2002 |isbn=9780072406559 |edition=9th |location=New York, NY |pages=600–606 |language=English}}{{Cite book |last=Incropera 1 Dewitt 2 Bergman 3 Lavigne 4 |first=Frank P. 1 David P. 2 Theodore L. 3 Adrienne S. 4 |title=Fundamentals of Heat and Mass Transfer |publisher=John Wiley and Sons, Inc. |year=2007 |isbn=9780471457282 |edition=6th |location=Hoboken, NJ |pages=941–950 |language=English}}
class="wikitable mw-collapsible mw-collapsed"
|Temperature (°C) |Density (kg/m3) |Specific heat (kJ/kg K) |Kinematic viscosity (m2/s) |Conductivity (W/m K) |Thermal diffusivity (m2/s) |Prandtl Number |Bulk modulus (K−1) |
−50
|1546.75 |0.875 |3.10×10−7 |0.067 |5.01×10−1 |6.2 |2.63×10−3 |
−40
|1518.71 |0.8847 |2.79×10−7 |0.069 |5.14×10−1 |5.4 |{{N/A}} |
−30
|1489.56 |0.8956 |2.53×10−7 |0.069 |5.26×10−1 |4.8 |{{N/A}} |
−20
|1460.57 |0.9073 |2.35×10−7 |0.071 |5.39×10−1 |4.4 |{{N/A}} |
−10
|1429.49 |0.9203 |2.21×10−7 |0.073 |5.50×10−1 |4 |{{N/A}} |
0
|1397.45 |0.9345 |2.14×10−7 |0.073 |5.57×10−1 |3.8 |{{N/A}} |
10
|1364.3 |0.9496 |2.03×10−7 |0.073 |5.60×10−1 |3.6 |{{N/A}} |
20
|1330.18 |0.9659 |1.98×10−7 |0.073 |5.60×10−1 |3.5 |{{N/A}} |
30
|1295.1 |0.9835 |1.94×10−7 |0.071 |5.60×10−1 |3.5 |{{N/A}} |
40
|1257.13 |1.0019 |1.91×10−7 |0.069 |5.55×10−1 |3.5 |{{N/A}} |
50
|1215.96 |1.0216 |1.90×10−7 |0.067 |5.45×10−1 |3.5 |{{N/A}} |
Gallery
File:Monthly means of CFC-12.png|CFC-12 measured by the Advanced Global Atmospheric Gases Experiment ([http://agage.mit.edu/ AGAGE]) in the lower atmosphere (troposphere) at stations around the world. Abundances are given as pollution free monthly mean mole fractions in parts-per-trillion.
File:Hats f12 global.png|Hemispheric and global mean CFC-12 concentrations (NOAA/ESRL)
Image:AYool CFC-12 history.png|Time-series of atmospheric concentrations of CFC-12 (Walker et al., 2000)
File:GLODAP sea-surf CFC12 AYool.png|1990s sea surface CFC-12 concentration
File:GLODAP invt CFC12 AYool.png|1990s CFC-12 oceanic vertical inventory
File:CFC-12 CFC-11 H-1211 SF6 vertical profiles Fairbanks Alaska 1976.png|CFC-12, CFC-11, H-1211 and SF6 vertical profiles
References
{{reflist}}
External links
- [http://www.esrl.noaa.gov/gmd/hats/combined/CFC12.html NOAA/ESRL CFC-12 global measurements]
- {{ICSC|0048|00}}
- [http://www.wou.edu/~avorder/Refrigeration.htm Overview of Freon-12 and some of its environmental problems]
- [https://web.archive.org/web/20071026084802/http://ptcl.chem.ox.ac.uk/MSDS/DI/dichlorodifluoromethane.html MSDS at Oxford University]
- [http://www.chemnet.ru/rus/handbook/ivtan/220.html Thermochemistry data at chemnet.ru]
- [https://web.archive.org/web/20080528143503/http://www.nist.gov/kinetics/spectra/ir_spectra/CF2Cl2%20(CFC-12)1.pdf IR absorption spectra]
- [https://www.cdc.gov/niosh/npg/npgd0192.html CDC - NIOSH Pocket Guide to Chemical Hazards]
{{E number infobox 930-949}}
{{fluorine compounds}}
{{Halomethanes}}
{{Authority control}}