Fiber Distributed Data Interface (FDDI) is a standard for data transmission in a local area network.
It uses optical fiber as its standard underlying physical medium.
It was also later specified to use copper cable, in which case it may be called CDDI (Copper Distributed Data Interface), standardized as TP-PMD (Twisted-Pair Physical Medium-Dependent), also referred to as TP-DDI (Twisted-Pair Distributed Data Interface).
FDDI was effectively made obsolete in local networks by Fast Ethernet which offered the same 100 Mbit/s speeds, but at a much lower cost and, from 1998 on, by Gigabit Ethernet due to its speed, even lower cost, and ubiquity.
Description
FDDI provides a 100 Mbit/s optical standard for data transmission in local area network that can extend in length up to {{convert|200|km|mi|sp=us}}.ANSI X3.263-1995 Although FDDI logical topology is a ring-based token network, it did not use the IEEE 802.5 Token Ring protocol as its basis; instead, its protocol was derived from the IEEE 802.4 token bus timed token protocol. In addition to covering large geographical areas, FDDI local area networks can support thousands of users. FDDI offers both a Dual-Attached Station (DAS), counter-rotating token ring topology and a Single-Attached Station (SAS), token bus passing ring topology.{{Cite book |title= FDDI and FDDI-II: architecture, protocols, and performance |author1=Bernhard Albert |author2=Anura P. Jayasumana |publisher= Artech House |year= 1994 |isbn= 978-0-89006-633-1}}
FDDI, as a product of American National Standards Institute X3T9.5 (now X3T12), conforms to the Open Systems Interconnection (OSI) model of functional layering using other protocols. The standards process started in the mid 1980s.{{Cite journal |title= FDDI - A tutorial |author= Floyd Ross |journal= IEEE Communications Magazine|publisher= IEEE Communications Society |doi= 10.1109/MCOM.1986.1093085 |pages= 10–17 |date= May 1986 |volume= 24 |number= 5|s2cid= 6989611 }}
FDDI-II, a version of FDDI described in 1989, added circuit-switched service capability to the network so that it could also handle voice and video signals.{{Cite book |author= Michael Teener and R. Gvozdanovic |title= [1989] Proceedings. 14th Conference on Local Computer Networks |chapter= FDDI-II operation and architectures |publisher= IEEE |doi= 10.1109/LCN.1989.65243 |isbn= 0-8186-1968-6 |pages= 49–61 |date= October 10, 1989 |s2cid= 29459918 }} Work started to connect FDDI networks to synchronous optical networking (SONET) technology.
An FDDI network contains two rings, one as a secondary backup in case the primary ring fails. The primary ring offers up to 100 Mbit/s capacity. When a network has no requirement for the secondary ring to do backup, it can also carry data, extending capacity to 200 Mbit/s. The single ring can extend the maximum distance; a dual ring can extend {{convert|100|km|mi|abbr=on}}. FDDI had a larger maximum frame size (4,352 bytes) than the standard Ethernet family, which only supports a maximum frame size of 1,500 bytes,{{efn|Jumbo frames can be used to extend Ethernet's maximum frame size to 9,000 bytes or more.}} allowing better effective data rates in some cases.
Topology
Designers normally constructed FDDI rings in a network topology such as a "dual ring of trees". A small number of devices, typically infrastructure devices such as routers and concentrators rather than host computers, were "dual-attached" to both rings. Host computers then connect as single-attached devices to the routers or concentrators. The dual ring in its most degenerate form simply collapses into a single device. Typically, a computer-room contained the whole dual ring, although some implementations deployed FDDI as a metropolitan area network.{{Cite journal |title= FDDI-II: A High Speed Integrated Service LAN |author= T. Boston |journal= Sixth European Fibre Optic Communications and Local Area Networks Exposition |publisher= Information Gatekeepers |isbn= 978-1-56851-055-2 |pages= 123–126 |date= June 29, 1988 }} Reprinted in Fiber Optic Metropolitan Area Networks (MANs) 1984-1991
FDDI requires this network topology because the dual ring actually passes through each connected device and requires each such device to remain continuously operational.
The standard actually allows for optical bypasses, but network engineers consider these unreliable and error-prone. Devices such as workstations and minicomputers that might not come under the control of the network managers are not suitable for connection to the dual ring.
As an alternative to using a dual-attached connection, a workstation can obtain the same degree of resilience through a dual-homed connection made simultaneously to two separate devices in the same FDDI ring. One of the connections becomes active while the other one is automatically blocked. If the first connection fails, the backup link takes over with no perceptible delay.{{foldoc|Fiber+Distributed+Data+Interface}}
{{IPstack}}
Frame format
class="wikitable"
|+ FDDI data frame format{{cite web |author=Wolfgang Schulte |title=Fiber Distributed Data Interface |url=https://wwwlehre.dhbw-stuttgart.de/~schulte/htme/55773.htm |access-date=2021-04-20}} |
Preamble, PA
| 16 bits |
---|
Start delimiter, SD
| 8 bits |
Frame control, FC
| 8 bits |
Destination address, DA
| 48 bits |
Source address, SA
| 48 bits |
Protocol (or packet) data unit, PDU
| Up to 4478 × 8 bits |
Frame check sequence, FCS
| 32 bits |
End delimiter/frame status, ED/FS
| 16 bits |
The frame check sequence uses the same cyclic redundancy check as Token Ring and Ethernet.
The Internet Engineering Task Force defined a standard for transmission of the Internet Protocol (which would be the protocol data unit in this case) over FDDI. It was first proposed in June 1989{{Cite journal |title= A Proposed Standard for the Transmission of IP Datagrams over FDDI Networks |journal= RFC 1103 |author= Dave Katz |publisher= IETF |date= June 1989 |doi= 10.17487/RFC1103 |url= http://tools.ietf.org/html/rfc1103 |access-date= August 15, 2013 |doi-access= free }} and revised in 1990.{{Cite journal |title= A Proposed Standard for the Transmission of IP Datagrams over FDDI Networks |journal= RFC 1183 |author= Dave Katz |publisher= IETF |date= June 1989 |doi= 10.17487/RFC1188 |url= http://tools.ietf.org/html/rfc1188 |access-date= August 15, 2013 |doi-access= free }} Some aspects of the protocol were compatible with the IEEE 802.2 standard for logical link control. For example, the 48-bit MAC addresses that became popular with the Ethernet family. Thus other protocols such as the Address Resolution Protocol (ARP) could be common as well.
Deployment
FDDI was considered an attractive campus backbone network technology in the early to mid 1990s since existing Ethernet networks only offered 10 Mbit/s data rates and Token Ring networks only offered 4 Mbit/s or 16 Mbit/s rates. Thus it was a relatively high-speed choice of that era, with speeds such as 100 Mbit/s.
By 1994, vendors included Cisco Systems, National Semiconductor, Network Peripherals, SysKonnect (acquired by Marvell Technology Group), and 3Com.{{Cite news |title= Wading Through Plethora of Options Poses Challenge for Life on the Fast LAN |work= Network World |pages= 41, 44, 46–49 |author= Mark Miller |date= March 21, 1994 |url= https://books.google.com/books?id=eA0EAAAAMBAJ&pg=PA47 |access-date= August 15, 2013 }}
FDDI installations have largely been replaced by Ethernet deployments.{{Cite book |title= Optical Fiber Communication: Principles and Systems |pages= 241–249 |author=A. Selvarajan |author2=Subrat Kar |author3=T. Srinivas |publisher= Tata McGraw-Hill Education |year=2003 |url= https://books.google.com/books?id=uyBSO4hf6DYC&pg=PA241 |isbn= 978-1-259-08220-7 }}
Standards
- ANSI X3.139-1987, Media Access Control (MAC) — also ISO 9314-2
- ANSI X3.148-1988, Physical Layer Protocol (PHY) — also ISO 9314-1
- ANSI X3.166-1989, Physical Medium Dependent (PMD) — also ISO 9314-3
- ANSI X3.184-1993, Single Mode Fiber Physical Medium Dependent (SMF-PMD) — also ISO 9314-4
- ANSI X3.229-1994, Station Management (SMT) — also ISO 9314-6
- ANSI X3.263-1995, Twisted Pair Physical Medium Dependent (TP-PMD)
Notes
{{Notelist}}