Hydroxyl tagging velocimetry
{{more footnotes|date=October 2015}}
Hydroxyl tagging velocimetry (HTV) is a velocimetry method used in humid air flows. The
method is often used in high-speed combusting flows because the high velocity and temperature
accentuate its advantages over similar methods. HTV uses a laser (often an argon-fluoride
excimer laser operating at ~193 nm) to dissociate the water in the flow into H + OH. Before entering the flow optics are
used to create a grid of laser beams. The water in the flow is dissociated only where beams of
sufficient energy pass through the flow, thus creating a grid in the flow where the
concentrations of hydroxyl (OH) are higher than in the surrounding flow. Another laser beam (at either ~248 nm or ~308 nm) in
the form of a sheet is also passed through the flow in the same plane as the grid. This laser
beam is tuned to a wavelength that causes the hydroxyl molecules to fluoresce in the UV spectrum. The fluorescence is then captured by a charge-coupled device (CCD) camera. Using
electronic timing methods the picture of the grid can be captured at nearly the same instant
that the grid is created.
By delaying the pulse of the fluorescence laser and the camera shot, an image of the grid that
has now displaced downstream can be captured. Computer programs are then used to compare the
two images and determine the displacement of the grid. By dividing the displacement by the known
time delay the two dimensional velocity field (in the plane of the grid) can be determined. Flow ratios, however, are shown to affect the impingement locations, where increased air flow ratios can reduce the required combustor size by isolating reaction products solely within the secondary cavity. {{Cite journal |last1=Kostka |first1=Stanislav |last2=Branam |first2=Richard D. |last3=Renfro |first3=Michael W. |last4=Lakusta |first4=Patrick J. |last5=Gord |first5=James R. |last6=Roy |first6=Sukesh |date=2012-05-01 |title=Laser-Induced Fluorescence Measurements of Product Penetration Within an Ultra-Compact-Combustor |url=https://arc.aiaa.org/doi/10.2514/1.B34092 |journal=Journal of Propulsion and Power |volume=28 |issue=3 |pages=617–624 |doi=10.2514/1.B34092}}
Other molecular tagging velocimetry (MTV) methods have used ozone (O3), excited oxygen and nitric oxide as the tag instead of hydroxyl. In the case of ozone the method is known as ozone tagging velocimetry or OTV. OTV has been developed and tested in many room air temperature applications with very accurate test results. OTV consists of an initial "write" step, where a 193-nm pulsed excimer laser creates ozone grid lines via oxygen (O2) UV absorption, and a subsequent "read" step, where a 248-nm excimer laser photodissociates the formed O3 and fluoresces the vibrationally excited O2 product thus revealing the grid lines' displacement.
References
{{Reflist}}
- {{cite journal
|author1=L.A. Ribarov
|author2=S. Hu
|author3=J.A. Wehrmeyer
|author4=R.W. Pitz
|title=Hydroxyl tagging velocimetry method optimization: signal intensity and spectroscopy
|journal=Applied Optics
|year=2005
|volume=44
|issue=31
|pages=6616–6626
|url=http://www.vuse.vanderbilt.edu/~combust/pdf/AppliedOpticsHtvSignalOptRibNov05.pdf
|doi=10.1364/AO.44.006616
|pmid=16270550
|bibcode=2005ApOpt..44.6616R
|url-status=dead
|archiveurl=https://web.archive.org/web/20100701213033/http://www.vuse.vanderbilt.edu/~combust/pdf/AppliedOpticsHtvSignalOptRibNov05.pdf
|archivedate=2010-07-01
}}
- {{cite journal
|author1=L.A. Ribarov
|author2=J.A. Wehrmeyer
|author3=S. Hu
|author4=R.W. Pitz
|title=Multiline hydroxyl tagging velocimetry measurements in reacting and nonreacting experimental flows
|journal=Experiments in Fluids
|year=2004
|volume=37
|issue=1
|pages=65–74
|url=http://www.vuse.vanderbilt.edu/Research_Groups/Laser_Diagnostics/pdf/HTV3.pdf
|doi=10.1007/s00348-004-0785-3
|bibcode=2004ExFl...37...65R
|s2cid=122840277
|url-status=dead
|archiveurl=https://web.archive.org/web/20110629174507/http://www.vuse.vanderbilt.edu/Research_Groups/Laser_Diagnostics/pdf/HTV3.pdf
|archivedate=2011-06-29
}}
- {{cite journal
|author1=L.A. Ribarov
|author2=J.A. Wehrmeyer
|author3=R.W. Pitz
|author4=R.A. Yetter
|title=Hydroxyl tagging velocimetry (HTV) in experimental air flows
|journal=Applied Physics B
|year=2002
|volume=74
|issue=2
|pages=175–183
|url=http://www.vuse.vanderbilt.edu/~combust/MST-J.pdf
|doi=10.1007/s003400100777
|bibcode=2002ApPhB..74..175R
|s2cid=122057285
|url-status=dead
|archiveurl=https://web.archive.org/web/20110629174533/http://www.vuse.vanderbilt.edu/~combust/MST-J.pdf
|archivedate=2011-06-29
}}
- {{cite journal |author1=R.W. Pitz |author2=J.A. Wehrmeyer |author3=L.A. Ribarov |author4=D.A. Oguss |author5=F. Batliwala |author6=P.A. DeBarber |author7=S. Deusch |author8=P.E. Dimotakis |title=Unseeded molecular flow tagging in cold and not flows using ozone and hydroxyl tagging velocimetry |journal=Measurement Science and Technology |year=2000 |volume=11 |issue=9 |pages=1259–1271 |url=http://www.vuse.vanderbilt.edu/~combust/htv.pdf |doi=10.1088/0957-0233/11/9/303 |bibcode=2000MeScT..11.1259P |s2cid=250920224 |url-status=dead |archiveurl=https://web.archive.org/web/20110604213149/http://www.vuse.vanderbilt.edu/~combust/htv.pdf |archivedate=2011-06-04 }}
- {{cite journal
|author1=J.A. Wehrmeyer
|author2=L.A. Ribarov
|author3=D.A. Oguss
|author4=R.W. Pitz
|title=Flame flow tagging velocimetry with 193-nm H2O photodissociation
|journal=Applied Optics
|year=1999
|volume=38
|issue=33
|pages=6912–6917
|url=http://www.vuse.vanderbilt.edu/Research_Groups/Laser_Diagnostics/ao.pdf
|doi=10.1364/AO.38.006912
|pmid=18324234
|bibcode=1999ApOpt..38.6912W
|url-status=dead
|archiveurl=https://web.archive.org/web/20110629174424/http://www.vuse.vanderbilt.edu/Research_Groups/Laser_Diagnostics/ao.pdf
|archivedate=2011-06-29
}}
- {{cite journal
|author=L.A. Ribarov, J.A. Wehrmeyer, F. Batliwala, R.W. Pitz, and P.A.DeBarber
|title=Ozone tagging velocimetry using narrowband excimer lasers
|journal=AIAA Journal
|year=1999
|volume=37
|issue=6
|pages=708–714
|url=http://pdf.aiaa.org/jaPreview/AIAAJ/1999/PVJAIMP799.pdf
|bibcode=1999AIAAJ..37..708R
|doi=10.2514/2.799
}}{{dead link|date=April 2017 |bot=InternetArchiveBot |fix-attempted=yes }}
{{DEFAULTSORT:Hydroxyl Tagging Velocimetry}}