IT energy management
{{Short description|Analysis and management of energy demand}}
{{Main|Green computing}}
IT energy management or Green IT is the analysis and management of energy demand within the Information Technology (IT) department in any organization. IT energy demand accounts for approximately 2% of global {{CO2}} emissions, approximately the same level as aviation,Gartner Press Release April 26, 2007, Gartner Estimates ICT Industry Accounts for 2 Percent of Global CO2 Emissions [https://web.archive.org/web/20070827000406/http://www.gartner.com/it/page.jsp?id=503867] and represents over 10% of all the global energy consumption (over 50% of aviation's energy consumption).MILLS, Mark P. The cloud begins with coal. Digital Power Group. Online at: http://www.tech-pundit.com/wp-content/uploads/2013/07/Cloud_Begins_With_Coal.pdf, 2013. IT can account for 25% of a modern office building's energy cost.Gartner Inc., "IT Vendors, Service Providers and Users Can lighten IT's Environmental footprint" Simon Mingay, December 5, 2007
At one point, the main sources of manageable IT energy demand were personal computers (PC)s and Monitors, accounting for 39% of energy use, followed by data centers and servers, accounting for 23% of energy use.Steve Kleynhans, VP Computing, Gartner presentation “the Green PC Environment” - presentation, New York, November 2007 In 2006, US IT infrastructures consumed an estimated 61 billion kWh of energy, totaling to a cost of $4.5 billion.{{Cite news|title=A Taxonomy and Survey of Energy-Efficient Data Centers and Cloud Computing Systems|last1=Beloglazov|first1=Anton|last2=Buyya|first2=Rajkumar|last3=Choon Lee|first3=Young|last4=Zomaya|first4=Albert|arxiv=1007.0066}} This constitutes about 1.5% of total US electricity consumption{{cite web |title=Electricity end use in the United States from 1975 to 2022 |url=https://www.statista.com/statistics/201794/us-electricity-consumption-since-1975/ |website=Statista |access-date=8 March 2024}} Significant opportunities exist for Enterprises to optimise their IT energy usage.E. Curry, B. Guyon, C. Sheridan, and B. Donnellan, [http://www.edwardcurry.org/publications/MISQE_SustainableIT_Intel_2012.pdf “Developing an Sustainable IT Capability: Lessons From Intel’s Journey,”] MIS Quarterly Executive, vol. 11, no. 2, pp. 61–74, 2012. Computers, data centers and networks consume 10% of the world's electricity{{cn|date=March 2024}}. 30% of this electricity goes to power terminal equipment (computers, mobiles and other devices), 30% goes to data centers and 40% goes to the network. A router may consume 1KW{{Cite web |title=Cisco Catalyst 8500 Series Edge Platforms Data Sheet |url=https://www.cisco.com/c/en/us/products/collateral/routers/catalyst-8500-series-edge-platforms/datasheet-c78-744089.html |access-date=2022-10-01 |website=Cisco |language=en}} and a large data center consumes nearly 100 MW.{{Cite web|url=https://news.cnrs.fr/articles/new-technologies-wasted-energies|title=New Technologies' Wasted Energies|website=CNRS News|language=en|access-date=2018-07-06}}
Data centers can consume up to 100 times more energy {{citation | url=http://energy.gov/eere/femp/data-center-energy-consumption-trends | title=Data Center Energy Consumption Trends}} than a standard office building. Often, less than 15% of original source energy is used for the information technology equipment within a data center. With the introduction of new technologies and products, energy management of several IT equipments has been greatly improved.
Server and data center power management
{{main|Data center environmental control}}
Servers and data centers account for 23% of IT energy demand. As hardware becomes smaller and less expensive, energy costs constitute a larger portion of server or data center costs.{{cite news|title = Power Provisioning for a Warehouse-sized Computer|journal = Proceedings of the ACM International Symposium on Computer Architecture, San Diego, CA|date = June 2007|url = http://www.seamicro.com/sites/default/files/Power%20Provisioning%20for%20a%20Warehouse-sized%20Computer.pdf|access-date = 2010-09-15|archive-date = 2017-08-12|archive-url = https://web.archive.org/web/20170812134536/http://seamicro.com/sites/default/files/Power%20Provisioning%20for%20a%20Warehouse-sized%20Computer.pdf|url-status = dead}}
These allow gains to be made through optimisation of servers. This is typically done by doing diagnostic tests on individual servers and developing a model for a data center's energy demand using these measurements. By analysing every server in a data centre, server power management software can identify servers that can be removed. It also enables servers to be virtualized, processes to be consolidated to a smaller number of servers, and servers with a predictable cyclical power demand to be fully powered down when not in use. Active power management features are also included which put remaining servers into their lowest power state that allows instant wake-up on demand when required.
Energy efficiency benchmarks, such as SPECpower, or specifications, like Average CPU power, can be used for comparing server efficiency and performance per watt.
PC power management
A research study shows that in the US, 50% of PCs are left on overnight, resulting in an estimated annual energy waste of 28.8 billion kWh, and a cost of $2.8 billion per year. User behaviour is slightly different in Europe, with approximately 28% of PCs being left on overnight in the UK, resulting in an estimated energy loss of 2.5 billion kWh, costing £300 million per year. In Germany, with approximately 30% of PCs left on overnight, it is estimated 4.8 billion kWh of energy are wasted each year, costing €919 million{{citation |title=PC Energy Report 2009, United States, United Kingdom, Germany |publisher=Alliance to Save Energy & 1E |date=March 2009 |url=http://www.climatesaverscomputing.org/docs/1E_PC_Energy_Report_2009_US.pdf |archive-url=https://web.archive.org/web/20120224153324/http://www.climatesaverscomputing.org/docs/1E_PC_Energy_Report_2009_US.pdf |archive-date=2012-02-24}} There is a significant market in third-party Power Management Software offering features beyond those present in the Windows operating system.{{cite web|url=http://www.windowsitpro.com/article/buyers-guide/Power-Management-Software-for-Windows-Workstations-Buyers-Guide.aspx|title=Power Management Software for Windows Workstations|access-date=2012-12-09|archive-url=https://web.archive.org/web/20101205111923/http://www.windowsitpro.com/article/buyers-guide/Power-Management-Software-for-Windows-Workstations-Buyers-Guide.aspx|archive-date=2010-12-05|url-status=dead}}{{cite web|url=http://www.energystar.gov/index.cfm?c=power_mgt.pr_power_mgt_comm_packages|title=Energy Star Commercial Packages List|access-date=2012-12-09|archive-date=2008-11-02|archive-url=https://web.archive.org/web/20081102002142/http://www.energystar.gov/index.cfm?c=power_mgt.pr_power_mgt_comm_packages|url-status=dead}}{{cite web|url=http://www.hmcsustainability.org.uk/energy.html|author=The Headmasters' and Headmistresses' Conference|title=HMC: A Practical Guide to Sustainable Building for Schools|access-date=2012-12-09|archive-url=https://web.archive.org/web/20120315230900/http://www.hmcsustainability.org.uk/energy.html|archive-date=2012-03-15|url-status=dead}}
Most products offer Active Directory integration and per-user/per-machine settings with the more advanced offering multiple power plans, scheduled power plans, anti-insomnia features and enterprise power usage reporting.
Energy-Efficient Ethernet
{{main|Energy-Efficient Ethernet}}
Energy-Efficient Ethernet (IEEE 802.3az) could reduce the energy use of networking equipment. In 2005, all the network-interface controllers in the United States (in computers, switches, and routers) used an estimated 5.3 terawatt-hours of electricity.{{Cite web|url=https://spectrum.ieee.org/energyefficient-ethernet |title=IEEE Spectrum: Energy-Efficient Ethernet |date=May 2008 |publisher=IEEE |access-date=2010-02-11}} According to a researcher at the Lawrence Berkeley Laboratory, Energy-Efficient Ethernet could save an estimated $450 million a year in energy costs in the U.S.{{Cite web |url=http://www.eetimes.com/news/latest/showArticle.jhtml?articleID=207601205 |title=Energy-efficient Ethernet standard gains traction |publisher=EETimes.com |access-date=2010-02-11 |archive-url=https://web.archive.org/web/20120929204456/http://www.eetimes.com/news/latest/showArticle.jhtml?articleID=207601205 |archive-date=2012-09-29 |url-status=dead }} With most of the savings from home computers ($200 million), and offices ($170 million), and the remaining $80 million from data centers. Energy-efficient Ethernet saves energy by allowing network links to either go into a low power sleep mode or run at a slower rate when there is no data. It also defines lower power signaling for use on higher quality cables.
Organisations and resources for IT energy management
There are a number of industry associations and policy organisations whose work on promoting energy-efficiency includes providing resources and information on IT energy management. These include:
- The Green Grid
- Alliance to Save Energy
- Climate Savers Computing Initiative
- 2Degrees (Low Carbon ITC Network)