Medical software
{{Short description|Type of software for medical purposes}}
Medical software is any software item or system used within a medical context.{{cite book |chapter-url=https://books.google.com/books?id=P3VeLRVMdQ8C&pg=PT275 |title=Medical Instrument Design and Development: From Requirements to Market Placements |chapter=Chapter 6: Medical Software |author1=Becchetti, C. |author2=Neri, A. |publisher=John Wiley & Sons Ltd |location=Chichester, U.K. |year=2013 |pages=359–418 |isbn=9781119952404}}{{cite book |chapter-url=https://books.google.com/books?id=LYxH-zUSOTgC&pg=PA27 |title=Medical Device Software Verification, Validation, and Compliance |chapter=Chapter 3: The FDA Software Validation Regulations and Why You Should Validate Software Anyway |author=Vogel, D.A. |publisher=Artech House |location=Boston, MA |year=2011 |pages=27–36 |isbn=9781596934238}}{{cite book |chapter-url=https://books.google.com/books?id=5I25BQAAQBAJ&pg=PA69 |title=Distributed Computing and Internet Technology: 9th International Conference, ICDCIT 2013, Bhubaneswar, India, February 5-8, 2013, Proceedings |chapter=Medical Software - Issues and Best Practices |author1=Jetley, R. |author2=Sudarsan, S. |author3=R., Sampath |author4=Ramaswamy, S. |publisher=Springer |location=Hyderabad, India |year=2013 |pages=69–91 |isbn=9783642360718}} This can include:
- Standalone software used for diagnostic or therapeutic purposes.
- Software used by health care providers to reduce paperwork and offer digital services to patients, e.g., a patient portal.
- Software embedded in a medical device (often referred to as "medical device software").
- Software that drives a medical device or determines how it is used.
- Software that acts as an accessory to a medical device.
- Software used in the design, production, and testing of a medical device (or)
- Software that provides quality control management of a medical device.
History
Medical software has been in use since at least since the 1960s,{{cite web |url=https://books.google.com/books?id=3WpVAAAAYAAJ&q=%22medical+software%22 |title=Radar and Electronics |publisher=Radar and Electronics Association |date=March 1963 |accessdate=26 April 2016}} a time when the first computerized information-handling system in the hospital sphere was being considered by Lockheed.{{cite book |url=https://books.google.com/books?id=8vsFGwAACAAJ |title=Lockheed Hospital Information System |publisher=Lockheed Aircraft Corporation |year=1965 |pages=82}}{{cite book |url=https://books.google.com/books?id=6RA7YzUXYg8C |title=Demonstration and evaluation of a total hospital information system |author1=Gall, John E. |author2=Norwood, Donald D. |author3=El Camino Hospital |publisher=U.S. Dept. of Health, Education, and Welfare, Public Health Service, Health Resources Administration, National Center for Health Services Research |series=NCHSR research summary series |year=1977 |pages=38}} As computing became more widespread and useful in the late 1970s and 1980s, the concept of "medical software" as a data and operations management tool in the medical industry—including in the physician's office—became more prevalent.{{cite book |url=https://books.google.com/books?id=8FprAAAAMAAJ |title=Computers for the Physician's Office |author1=Zimmerman, J. |author2=Rector, A. |publisher=Research Studies Press |location=Forest Grove, OR |pages=305 |year=1978 |isbn=0893550078}}{{cite book |url=https://books.google.com/books?id=xW1LAAAAYAAJ |title=Computers in Healthcare, Volume 6 |chapter=Consultants Perspective on Medical Office Computerization |author1=Freedman, E. |author2=Hecht, E. |author3=Whiteside, D. |publisher=Cardiff Publishing Company |location=Englewood |year=1985}} Medical software became more prominent in medical devices in fields such as nuclear medicine, cardiology, and medical robotics by the early 1990s, prompting additional scrutiny of the "safety-critical" nature of medical software in the research and legislative communities, in part fueled by the Therac-25 radiation therapy device scandal.{{cite journal |title=Quality assurance of medical software |journal=Journal of Medical Engineering & Technology |author=Cosgriff, P.S. |volume=18 |issue=1 |pages=1–10 |year=1994 |doi=10.3109/03091909409030782 |pmid=8006924}}{{cite web |url=http://www.embedded.com/design/prototyping-and-development/4008888/A-Formal-Methods-based-verification-approach-to-medical-device-software-analysis |title=A Formal Methods-based verification approach to medical device software analysis |author1=Jones, P. |author2=Jetley, R. |author3=Abraham, J. |work=Embedded |publisher=UBM |date=9 February 2010 |accessdate=26 April 2016}}
The development of the ISO 9000-3 standard as well as the European Medical Devices Directive in 1993 helped bring some harmonization of existing laws with medical devices and their associated software, and the addition of IEC 62304 in 2006 further cemented how medical device software should be developed and tested.{{cite web |url=https://webstore.iec.ch/preview/info_iec62304%7Bed1.0%7Den_d.pdf |title=Medical device software – Software life cycle processes |work=International Standard IEC 62304, First Edition 2006-05 |publisher=International Electrotechnical Commission |author=International Electrotechnical Commission |year=2006 |accessdate=26 April 2016}} The U.S. Food and Drug Administration (FDA) has also offered guidance and driven regulation on medical software, particularly embedded in and used as medical devices.{{cite web |url=https://www.fda.gov/downloads/MedicalDevices/.../ucm073779.pdf |archive-url=https://web.archive.org/web/20151129101241/http://www.fda.gov/downloads/MedicalDevices/.../ucm073779.pdf |url-status=dead |archive-date=November 29, 2015 |title=Guidance for Industry, FDA Reviewers and Compliance on Off-The-Shelf Software Use in Medical Devices |author=Office of Device Evaluation, Center for Devices and Radiological Health |publisher=U.S. Food and Drug Administration |date=9 September 1999 |accessdate=26 April 2016}}{{cite web |url=https://www.fda.gov/RegulatoryInformation/Guidances/ucm089543.htm |archive-url=https://web.archive.org/web/20150208055456/http://www.fda.gov/RegulatoryInformation/Guidances/ucm089543.htm |url-status=dead |archive-date=February 8, 2015 |title=Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices |author1=Center for Devices |author2=Radiological Health |publisher=U.S. Food and Drug Administration |date=11 May 2005 |accessdate=26 April 2016}}{{Cite web | url=https://www.smartclinics.com.au/doctors-near-me/ |title = Doctors near me}} There was an expansion of medical software innovation with the adoption of electronic health records (EHR) and availability of electronic clinical data. In the United States, substantial resources were allocated, starting with the HITECH Act of 2009. {{Cite web | url=https://www.healthit.gov/topic/laws-regulation-and-policy/health-it-legislation|title = HITECH Act of 2009}}
Medical device software
The global IEC 62304 standard on the software life cycle processes of medical device software states it is a "software system that has been developed for the purpose of being incorporated into the medical device being developed or that is intended for use as a medical device in its own right." In the U.S., the FDA states that "any software that meets the legal definition of a [medical] device" is considered medical device software.{{cite web |url=https://www.fda.gov/downloads/Training/CDRHLearn/UCM209129.pdf |archive-url=https://web.archive.org/web/20110704050334/http://www.fda.gov/downloads/Training/CDRHLearn/UCM209129.pdf |url-status=dead |archive-date=July 4, 2011 |title=CDRH Regulated Software: An Introduction |author=Murray Jr., J.F. |publisher=U.S. Food and Drug Administration |date=March 2010 |accessdate=26 April 2016}} A similar "software can be a medical device" interpretation was also made by the European Union in 2007 with an update to its European Medical Devices Directive, when "used specifically for diagnostic and/or therapeutic purposes."{{cite web |url=http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2007:247:0021:0055:en:PDF |format=PDF |title=Directive 2007/47/ED of the European Parliament and of the Council |work=Official Journal of the European Union |publisher=European Union |date=5 September 2007 |accessdate=26 April 2016}}
Due to the broad scope covered by these terms, manifold classifications can be proposed for various medical software, based for instance on their technical nature (embedded in a device or standalone), on their level of safety (from the most trivial to the most safety-critical ones), or on their primary function (treatment, education, diagnostics, and/or data management).
A key distinction in medical software classification is between Software in a Medical Device (SiMD)and Software as a Medical Device (SaMD). SiMD refers to software that is essential for a medical device to function, such as control software for robotic surgical systems or firmware in diagnostic instruments. SaMD, on the other hand, operates independently of a hardware device and is designed to fulfill a medical purpose on its own.
=Software as a medical device=
The dramatic increase in smartphone usage in the twenty-first century triggered the emergence of thousands of standalone health- and medical-related software apps, many falling into a gray or borderline area in terms of regulation.{{cite web |title=Technology in healthcare: how software improves medical practice? |url=https://www.labsexplorer.com/c/technology-in-healthcare-how-software-improves-medical-practice_216 |website=Labs Explorer |accessdate=5 May 2020}} While software embedded into a medical device was being addressed, medical software separate from medical hardware—referred to by the International Medical Device Regulators Forum (IMDRF) as "software as a medical device" or "SaMD"{{cite web |url=http://www.imdrf.org/docs/imdrf/final/technical/imdrf-tech-131209-samd-key-definitions-140901.pdf |title=Software as a Medical Device (SaMD): Key Definitions |author=Spanou, D. |publisher=International Medical Device Regulators Forum |pages=9 |date=9 December 2013 |accessdate=26 April 2016}}—was falling through existing regulatory cracks.
In the U.S., the FDA eventually released new draft guidance in July 2011 on "mobile medical applications," with members of the legal community, such as Keith Barritt, speculating it should be read to imply "as applicable to all software, since the test for determining whether a mobile application is a regulated mobile 'medical' application is the same test one would use to determine if any software is regulated."{{cite journal |url=http://www.fr.com/files/Uploads/Documents/Barritt,%20Keith.%20BNA%20Medical%20Devices%20Law%20&%20Industry%20Report.%20New%20FDA%20Draft%20Guidance.%2008-10-11.pdf |title=New FDA Draft Guidance Sheds Light On Regulation of 'Mobile Medical Apps' and Other Software |journal=Medical Devices Law & Industry Report |volume=5 |issue=16 |pages=1–3 |date=August 2011 |accessdate=26 April 2016 |archive-url=https://web.archive.org/web/20131127030705/http://www.fr.com/files/Uploads/Documents/Barritt%2C%20Keith.%20BNA%20Medical%20Devices%20Law%20%26%20Industry%20Report.%20New%20FDA%20Draft%20Guidance.%2008-10-11.pdf |archive-date=27 November 2013 |url-status=dead }} Examples of mobile apps potentially covered by the guidance included those that regulate an installed pacemaker or those that analyze images for cancerous lesions, X-rays and MRI, graphic data such as EEG waveforms as well as bedside monitors, urine analyzers, glucometer, stethoscopes, spirometers, BMI calculators, heart rate monitors, and body fat calculators.{{cite journal |title=The regulation of mobile medical applications |journal=Lab on a Chip |author1=Yetisen, A.K. |author2=Martinez-Hurtado, J.L. |author3=Vasconcellos, F.C. |author4=Simsekler, M.C.E. |author5=Akram, M.S. |author6=Lowe, C.R. |volume=14 |issue=5 |pages=833–840 |year=2014 |doi=10.1039/C3LC51235E |pmid=24425070}}
By the time its final guidance was released in late 2013, however, members of Congress began to be concerned about how the guidance would be used in the future, in particular with what it would mean to the SOFTWARE Act legislation that had recently been introduced.{{cite web |url=http://www.fiercemobilehealthcare.com/story/congress-fda-odds-over-software-medical-device/2013-11-20 |title=Congress, FDA at odds over software as a medical device |author=Slabodkin, G. |work=Fierce Mobile Healthcare |publisher=Questex, LLC |date=20 November 2013}} Around the same time, the IMDRF was working on a more global perspective of SaMD with the release of its Key Definitions in December 2013, focused on "[establishing] a common framework for regulators to incorporate converged controls into their regulatory approaches for SaMD." Aside from "not [being] necessary for a hardware medical device to achieve its intended medical purpose," the IMDRF also found that SaMD also could not drive a medical device, though it could be used as a module of or interfaced with one. The group further developed quality management system principles for SaMD in 2015.{{cite web |url=http://www.raps.org/Regulatory-Focus/News/2015/04/08/21936/IMDRF-Proposes-QMS-Principles-for-Software-as-a-Medical-Device/ |title=IMDRF Proposes QMS Principles for Software as a Medical Device |author=Mezher, M. |work=Regulatory Focus |publisher=Regulatory Affairs Professionals Society |date=8 April 2015 |accessdate=26 April 2016}}
= Software in a medical device =
Software in a medical device (SiMD) refers to software that is integral to the operation of a physical medical device. Unlike SaMD, which functions independently, SiMD is embedded within or necessary for the device's intended medical purpose. Examples include software that controls an artificial cardiac pacemaker, manages infusion pumps, or operates imaging systems like MRI machines.
The development and maintenance of SiMD are governed by international standards to ensure safety and efficacy. IEC 62304:2006 outlines the life cycle requirements for medical device software, establishing a framework for processes, activities, and tasks throughout the software's life cycle. Additionally, ISO 13485:2016 specifies requirements for a quality management system in the design and manufacture of medical devices, including software components.
International standards
IEC 62304 has become the benchmark standard for the development of medical device software, standalone or otherwise, in both the E.U. and the U.S.{{cite book |chapter-url=https://books.google.com/books?id=u3zMCQAAQBAJ&pg=PA19 |title=Software Process Improvement and Capability Determination |chapter=Software Process Improvement and Roadmapping – A Roadmap for Implementing IEC 62304 in Organizations Developing and Maintaining Medical Device Software |author1=Rust, P. |author2=Flood, D. |author3=McCaffery, F. |editor1=Rout, T. |editor2=C'Connor, R.V. |editor3=Dorling, A. |publisher=Springer |location=Cham, Switzerland |year=2015 |pages=19–32 |isbn=9783319198606 |doi=10.1007/978-3-319-19860-6_3}} Innovation in software technologies has led key industry leaders and government regulators to recognize the emergence of numerous standalone medical software products that operate as medical devices. This has been reflected in regulatory changes in the E.U. (European Medical Devices Directive) and the U.S. (various FDA guidance documents). Additionally, quality management system requirements for manufacturing a software medical device, as is the case with any medical device, are described in the U.S. Quality Systems Regulation{{cite web |url=https://www.fda.gov/medicaldevices/deviceregulationandguidance/postmarketrequirements/qualitysystemsregulations/default.htm |archive-url=https://web.archive.org/web/20090604110046/http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/PostmarketRequirements/QualitySystemsRegulations/default.htm |url-status=dead |archive-date=June 4, 2009 |title=Quality System (QS) Regulation/Medical Device Good Manufacturing Practices |publisher=U.S. Food and Drug Administration |date=30 June 2014 |accessdate=26 April 2016}} of the FDA and also in ISO 13485:2016.
Software technology manufacturers that operate within the software medical device space conduct mandatory development of their products in accordance with those requirements. Furthermore, though not mandatory, they may elect to obtain certification from a notified body, having implemented such quality system requirements as described within international standards such as ISO 13485:2016.
Further reading
- Babelotzky, W; Bohrt, C.; Choudhuri, J.; Handorn, B.; Heidenreich, G.; Neuder, K.; Neumann, G.; Prinz, T.; Rösch, A.; Spyra, G.; Stephan, S.; Wenner, H.; Wufka, M. (2018) [https://books.google.com/books?id=CKjPvQEACAAJ&q=Development+and+Production+of+Medical+Software+:+Standards+in+Medical+Engineering Development and Production of Medical Software : Standards in Medical Engineering]. VDE VERLAG GMBH. pp. 1-207. {{ISBN|9783800745388}}.
- {{cite book |chapter-url=https://books.google.com/books?id=P3VeLRVMdQ8C&pg=PT275 |title=Medical Instrument Design and Development: From Requirements to Market Placements |chapter=Chapter 6: Medical Software |author1=Becchetti, C. |author2=Neri, A. |publisher=John Wiley & Sons Ltd |location=Chichester, U.K. |year=2013 |pages=359–418 |isbn=9781119952404}}
- {{cite book |chapter-url=https://books.google.com/books?id=obfDBAAAQBAJ&pg=PA26 |title=Introduction to Clinical Informatics |chapter=Chapter 2: Medical Software Development |author1=Degoulet, P. |author2=Fieschi, M. |publisher=Springer Science & Business Media |location=New York |year=2012 |pages=19–34 |isbn=9781461268659}}
See also
External links
{{commonscat-inline|Medical software}}