Personal RF safety monitor

Electromagnetic field monitors measure the exposure to electromagnetic radiation in certain ranges of the

electromagnetic spectrum. This article concentrates on monitors used in the telecommunication industry, which measure exposure to radio spectrum radiation. Other monitors, like extremely low frequency monitors which measure exposure to radiation from electric power lines, also exist. The major difference between a "Monitor" and a "Dosimeter" is that a Dosimeter can measure the absorbed dose of ionizing radiation, which does not exist for RF Monitors. Monitors are also separated by "RF Monitors" that simply measure fields and "RF Personal Monitors" that are designed to function while mounted on the human body.

Introduction

File:FSG0352-DIA-1 Wikipedia Comparison Graph.png

Electromagnetic field monitors, as used in the cellular phone industry, are referred as "personal RF safety monitors", personal protection monitors (PPM) or RF exposimeters.{{Cite book | url=https://books.google.com/books?id=V8Lk2ghPl7IC&q=fcc+rf+monitors+ppm&pg=PA1904 | title=National Association of Broadcasters Engineering Handbook| isbn=9780240807515| last1=Williams| first1=Edmund A.| last2=Jones| first2=Graham A.| last3=Layer| first3=David H.| last4=Osenkowsky| first4=Thomas G.| year=2007| publisher=Taylor & Francis}} They form part of the personal protective equipment worn by a person working in areas exposed to radio spectrum radiation. A personal RF safety monitor is typically worn either on the torso region of the body or handheld and is required by the occupational safety and health acts of many telecommunication companies.

Most of the scientifically proven RF safety monitors are designed to measure the RF exposure as a percentage of the two most common international RF safety guidelines: International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines{{Cite web|url=https://www.osha.gov/dts/osta/otm/otm_ii/otm_ii_3.html|title=OSHA Technical Manual (OTM) {{pipe}} Occupational Safety and Health Administration}} and the U.S. Federal Communications Commission (FCC).{{Cite web|url=http://www.fcc.gov/oet/ea/eameasurements.html|title=Equipment Authorization - Measurement Procedures|date=19 December 2014}} The ICNIRP guidelines are also endorsed by the WHO.{{cite web|url=https://www.who.int/peh-emf/meetings/en/Cape_Town_meet_report_12-01.pdf |title=WHO/ICNIRP Conference on EMF Biological Effects |publisher= World Health Organization |date=2001-12-10}} RF personal safety monitors were originally designed for RF Engineers working in environments where they could be exposed to high levels of RF energy or be working close to a RF source, for example working at the top of a telecommunication tower, or working on the rooftop of a building where transmitting antennas are present. Most international RF safety programs include the training and use of RF personal safety monitors and the IEEE C95.7 specifies what is a RF Personal Monitor.[https://ieeexplore.ieee.org/document/1611107/ IEEE]|title"IEEE Recommended Practice for Radio Frequency Safety Programs, 3 kHz to 300 GHz," IEEE, International Committee on Electromagnetic Safety, New York, IEEE Std C95.7, 2014

In some cases the RF safety monitor comes in a version or mode for the general public.{{cite web |date= |title=Public product info |url=http://www.fieldsense.com/public.php |url-status=dead |accessdate=2012-04-02 |publisher=FieldSENSE}} These meters can then be used to determine areas where the public might be exposed to high levels of RF energy or used to indicate the RF level in areas where the general public has access.

Specification

The specifications of a RF monitor determines the work environment where could be applicable. Wideband RF monitors can be used at a broader variety of base station sites than for example a narrowband, cellular RF monitor which is designed only to be used in the mobile telephone- and data networks. IEEE Std C95.3 states that "In the region between 1-100 GHz, resistive thermoelectric dipoles are used as sensors with a background of lossy material to reduce the effect of scattering from the body. Electrically short dipoles with diode detectors as sensors may cover a portion of this range". The results of monitors which do not incorporate "lossy material" to reduce the effects of scattering, are questionable on the body.

The type of response is a basic feature of any RF personal monitor and can be expressed in two basic parameters:

  • Directivity: Some of them have an isotropic response, which means that they are able to measure RF fields from any space direction. Others, like radial field monitors, have a partial space coverage, and have to be worn in a specific way in order to provide a correct reading.
  • Frequency response:
  • Flat response: units that have a flat response for all the frequency range covered, i.e. the response does not change with frequency.
  • Shaped response: contain frequency dependent sensors that automatically weight the detected RF fields in accordance with frequency-dependent RF exposure limits.

It is common that RF personal monitors provide results as a percentage (%) of frequency-dependent limit values of a specific standard (sometimes called reference levels or MPE, maximum permissible exposure). It is important to be careful interpreting exposure during an alarm condition based on a % result; shaped response RF personal monitors will provide a result as a % of the standard, independently of the frequency, while flat response monitors will provide a result as a % of a particular value (not frequency-dependent), so it is important to know which is the particular value this % is referring to.

Some RF personal monitors have different versions, shaped to each standard, so they will be more accurate, but can be used only for that standard. Others have a single version, so will be less accurate, but can be used for different standards.

Usually, the alarm of most RF personal monitors is triggered by instant values, however, standard limits are specified as time-averaged values. Some RF monitors have the possibility to trigger alarms based on average values, which is a better indication of the real exposure situation (as an example, an instant value can be at 200% while the average being below 100%).

As they are typically small, portable units, they are usually equipped with only a few LEDs for a rough field level indication (50%, 100%, etc). Nevertheless, some of them have a datalogger that allows to download the measurements, check for the exact values, and keep a history record of the exposures. Wavecontrol's WaveMon has available a GPS and altimeter to include position information to the data records.

Other specifications that may be relevant, depending on the application are battery characteristics (lifetime, ways to change or recharge), dimensions, weight, and operating temperature.

The following table shows different basic specifications of some RF monitors:

class="wikitable"
SpecificationEME Guard XS{{cite web|url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-xs|title=EME Guard XS|website=RF Monitors EME Guard XS|publisher=mvg-world.com|accessdate=2020-06-11}}Narda RadMan XT{{cite web|url=https://www.narda-sts.us/pdf_files/RadManXT-p76.pdf|title=Narda STS RadMan XT Datasheet|last=|first=|date=|website=|publisher=Narda-sts.us|accessdate=2012-06-06}}

!Narda RadMan 2LT{{cite web|url=https://www.narda-sts.com/en/personal-safety-emf/radman-2-xt-/-radman-2-lt/|title=Narda Radman 2|last=|first=|date=|website=|publisher=Narda-sts.com|accessdate=2023-08-11}}

!Narda RadMan 2XT

!WaveMon RF-8{{Cite web|url=https://www.wavecontrol.com/rfsafety/en/products/personal-safety/wavemon|title=WaveMon RF-8. Broadband Personal monitor|website=Waveconrol}}

SafeOne{{Cite web|url=http://www.lbagroup.com/products/safeone-rf-monitors|title = SafeOnePRO Personal RF Safety Monitor PPE: Light, Tuff, All Cell Band}}

!fieldSENSE 2.0

fieldSENSE60{{cite web |date= |title=FieldSENSE |url=https://fieldsense.com/fieldsense-60-data-sheet/ |url-status=live |accessdate=2025-01-30 |publisher=FieldSENSE}}EME Guard Plus{{cite web|url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-plus|title=EME Guard Plus|website=RF Monitors EME Guard Plus|publisher=mvg-world.com|accessdate=2020-06-11}}

!WaveMon RF-60{{Cite web|url=https://www.wavecontrol.com/rfsafety/en/products/personal-safety/wavemon-rf40|title=WaveMon RF-60 - 60 GHz RF Personal Monitor|last=|first=|date=|website=Wavecontrol|access-date=}}

Nardalert S3{{cite web|url=http://www.narda-sts.us/pdf_files/DataSheets/NardalertS3_DataSheet.pdf|title=Narda Safety Test Solutions Nardalert S3 Datasheet |publisher=Narda-sts.us |date= |accessdate=2016-06-06}}

!EME Guard XS 40GHz {{cite web|url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-xs-40-ghz|title=MVG OCCUPATIONAL RF SAFETY-EME Guard XS 40GHz |publisher=mvg-world.com |date= |accessdate=2021-05-05}}

Frequency Range80 MHz – 6 GHzE-Field

1 MHz - 40 GHz (ICNIRP)

3 MHz - 40 GHz (FCC)

10 MHz - 40 GHz (SC6)

H-Field

27 MHz - 1 GHz (ICNIRP,

SC6)

3 MHz – 1 GHz (FCC)

|E-Field

50 MHz – 8 GHz

H-Field

50 MHz – 1 GHz

|E-Field

900 kHz – 60 GHz (ICNIRP models)

3 MHz – 60 GHz (FCC models)

10 MHz – 60 GHz (SC6 models)

H-Field

27 MHz – 1 GHz (ICNIRP, SC6 models)

3 MHz – 1 GHz (FCC models)

|E-Field: 300 kHz - 8 GHz

H-Field 3 MHz – 1 GHz

10-10000 MHz

|E-Field 50 MHz - 6 GHz

H-Field 50 MHz – 1 GHz

E-Field 50 MHz - 60 GHz

H-Field 50 MHz – 1 GHz

1 MHz- 40 GHz

|E-Field: 100 kHz - 60 GHz

H-Field: 3 MHz - 1 GHz

| 100 kHz – 100 GHz

|1 MHz – 40 GHz

DirectivityIsotropic (Tri-axial)Isotropic (Tri-axial)

|Isotropic (Tri-axial)

|Isotropic (Tri-axial)

|Isotropic (Tri-axial)

Isotropic (Tri-axial)

|Isotropic (Tri-axial)

Isotropic (Tri-axial)Isotropic (Tri-axial)

|Isotropic (Tri-axial)

Radial and Dual-polarized

|Isotropic (Tri-axial)

Frequency Response

|Flat

|Shaped

|Shaped

|Shaped

|Shaped

|Flat

|Shaped

|Shaped

|Flat

|Shaped

|Shaped

|Flat

50/60 Hz immunityN/A1 kV/m

|10 kV/m

|10 kV/m

|30 kV/m

N/A

|N/A

N/AN/A

|30 kV/m

100 kV/m

| N/A

Designed to be worn on the Body (per IEEE C95.3)NoYes

|Yes

|Yes

|Yes

No

|Yes

YesNo

|Yes

Yes

| No

Reference standardICNIRP 2020

FCC

Safety Code 6 2015

User-definable

2004/40/EC

ICNIRP

FCC

Safety Code 6

ICNIRP General Public

(separate model)

|ICNIRP

FCC

Safety Code 6

ICNIRP General Public (separate model)

|ICNIRP

ICNIRP General Public

FCC

Safety Code 6

|FCC

EU Directive (2013/35/EU)

ICNIRP

Safety Code 6 (2015)

ICNIRP

FCC

IEEE

NCRP

Safety Code 6

|ICNIRP

FCC (NCRP)

IEEE

Safety Code 6

EU Directive

ICNIRP

FCC (NCRP)

IEEE

Safety Code 6

EU Directive

ICNIRP 2020

FCC

Safety Code 6 2015

User-definable

|FCC

EU Directive (2013/35/EU)

ICNIRP

Safety Code 6 (2015)

NATO

FCC

IEEE C95.1

Safety Code 6 (2015)

ICNIRP

|ICNIRP 2020

FCC 96-326

Safety Code 6 2015

2013/35/UE

Exposure level indicators1 X LED => 1%

2 X LED => 5%

3 X LED => 20%

4 X LED => 100%

5 X LED => 225%

6 X LED => 500%

7 X LED => 2000%

(Broadcast 100 MHz: Visual & Audio Alarms

Activated 5 to 350 V/m

User-definable at factory)

1 X LED => 12.5%

2 X LED => 25%

3 X LED => 50% (Buzzer alarm)

4 X LED => 100% (Buzzer alarm)

|1 X LED => 5%

2 X LED => 10%

3 X LED => 25%

4 X LED => 50%

5 X LED => 100%

6 X LED => 200%

=> 50%: visual, audible and vibration indicators

=> 100%: strong visual, audible and vibration indicators

|1 X LED => 5%

2 X LED => 10%

3 X LED => 25%

4 X LED => 50%

5 X LED => 100%

6 X LED => 200%

=> 50%: visual, audible and vibration indicators

=> 100%: strong visual, audible and vibration indicators

|1 X LED => 10%

2 X LED => 25%

3 X LED => 50%

4 X LED => 75%

5 X LED => 100%

6 X LED => 200%

Visual, Audio & Vibration Alarms.

Adjustable by user.

|1 X LED => 2%

2 X LED => 5%

3 X LED => 10%

4 X LED => 25%

5 X LED => 50% (0.75 Hz buzzer alarm)

6 X LED => 100% (1.5 Hz buzzer alarm)

7 X LED => 200% (3 Hz buzzer alarm)

1 X LED => 2%

2 X LED => 5%

3 X LED => 10%

4 X LED => 25%

5 X LED => 50% (0.75 Hz buzzer alarm)

6 X LED => 100% (1.5 Hz buzzer alarm)

7 X LED => 200% (3 Hz buzzer alarm)

1 x LED=> 6%

2 x LED=> 12%

3 x LED=> 25%

4 x LED=> 50%

5 x LED=> 100%

6 x LED=> 200%

(Visual, Audio and Vibration alarms adjustable )

|1 X LED => 10%

2 X LED => 25%

3 X LED => 50%

4 X LED => 75%

5 X LED => 100%

6 X LED => 200%

Visual, Audio & Vibration Alarms.

Adjustable by user.

LED Display of the Actual Value

Two LED Alarm Indicators (Visual)

Two Audio Alarm Indicators

Vibration Alarm Indicator

User Variable in 50% increments

Defaults are 50 and 200%

1 X LED => 0.4%

2 X LED => 2%

3 X LED => 10%

4 X LED => 40%

5 X LED => 100%

6 X LED => 200%

7 X LED => 800%

Data loggerNoYes

|Yes

|Yes

|Yes

No

|Yes

YesYes

|Yes

Yes (Option)

|No

GPS

|No

|No

|No

|No

|Yes

|No

|No

|No

|No

|Yes

|No

|No

Altimeter

|No

|No

|No

|No

|Yes

|No

|No

|No

|No

|Yes

|No

|No

Battery life>100 hours200 hours

|800 hours

(Rechargeable via USB)

|800 hours

(Rechargeable via USB)

|>200 hours (Rechargeable via USB)

| 2,000 hours

|6-12 months average use

6 to 12 months on ave usage |6-12 months average use

| Recording mode:

>300 hours

Non-recording mode:

>3 months (8 hours/day)

|>200 hours (Rechargeable via USB)

25 hours (Rechargeable via USB)

|> 1000 hours

Dimensions132.5 x 48.5 x 28.7 mm163 x 41 x 37 mm

|165 x 47 x 31 mm

|165 x 47 x 31 mm

|174 x 42.5 x 33 mm

| 58 x 105 x 23 mm

|146 X 42 X 26 mm

146 X 42 X 26 mm172.6 X 59 X 35.5 mm

|174 x 42.5 x 33 mm

117 x 83 x 32 mm

|132.5 x 48.5 x 28.7 mm ( LxWxH)

Weight120g130g

|185g

|185g

|190g

88g

|115 g

115 g275g

|190g

230g

|120 g

Operating temperature|
10°C to +50°C |
10°C to + 55°C

| -10°C to + 55°C

| -10°C to + 55°C

| -20 °C to +50 °C

-10°C to +40°C

| -20 °C to +50 °C

-20 °C to +50 °C-20°C to +55°C

| -20 °C to +50 °C

-10°C to +50°C |
10°C to +50°C
10°C to 50°C
Calibration interval24 Months36 months

|36 months

|36 months

|24 Months

24 Months

|24 Months

24 Months24 Months

|24 Months

48 months

|24 Months

NIST/ILAC Traceable CalibrationNoYes

|Yes

|Yes

|Yes

No

|Yes

YesNo

|Yes

Yes

|No

Fall Detection AlarmNoNo

|No

|No

|Yes

No

|Yes

YesNo

|Yes

No

|No

Approx. price USD$550$1000

|$600

|$1200

|$900

$700

|$599

$799$999

|$1400

$1700

|$799

Operating instructions

Each specific personal RF safety monitor has its own operating instructions. And most of the monitors have different operating modes. For instance, the Narda Radman has a mode in which it can be body worn by the operator, but it also has a probe mode where the operator can scan certain areas to find accurate exclusion zones.{{cite web|url=http://www.narda-sts.de/faq.html?qid=021|title=Radman - Measure and probe mode}} The FieldSENSE on the other hand has a monitor and measure mode.{{cite web |title=FieldSENSE - Measure and monitor mode |url=http://www.fieldsense.com/occupational.php |url-status=dead}} The measure mode is similar to the Radman's probe mode, but the monitor mode is used by mounting the FieldSENSE onto an inactive antenna and then it is safe to work on the antenna until the FieldSENSE raise an alarm to warn RF technicians that the antenna is live and that any work on the antennas should be ceased until deactivation is confirmed. The Wavecontrol's WaveMon{{Cite web|url=https://www.wavecontrol.com/rfsafety/en/products/personal-safety|title=WaveMon RF personal monitors|website=Wavecontrol}} and Narda's RadMan 2[29] can be body-worn, and used off the body as a probe or as a monitor. Most of the RF monitors such as the FieldSENSE, EME Guard, WaveMon and the RadMan 2 also have a data logging functionality that can log the RF exposure of a worker over time.{{cite web|url=http://www.narda-sts.us/pdf_files/DataSheets/Radman_DataSheet.pdf |title=Narda Safety Test Solutions |publisher=Narda-sts.us |date= |accessdate=2012-04-02}}{{cite web|url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard|title=EME Guard|website=RF Monitors EME Guard|publisher=mvg-world.com|accessdate=2020-06-11}} The RadMan 2XT's RF detection mode with its tone search feature can locate leaks in waveguides and verify that an antenna is turned off. [https://www.narda-sts.com/en/personal-safety-emf/radman-2-xt-radman-2-lt-radman-radman-xt/ [30]]

List of personal RF monitors

  • EME Guard Plus{{cite web|url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-plus |title=EME Guard Plus - MVG (Satimo) |publisher=mvg-world.com |date=2020-06-11 |accessdate=2020-06-11}}
  • EME Guard XS{{cite web|url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-xs |title=EME Guard XS - MVG (Satimo) | publisher=mvg-world |date=2020-06-11 |accessdate=2020-06-11}}
  • EME Guard XS 40 GHz{{cite web|url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-xs-40-ghz |title=EME Guard XS 40 GHz- MVG (Satimo) | publisher=mvg-world |date=2020-06-11 |accessdate=2020-06-11}}
  • EME SPY Evolution{{cite web|url=https://www.mvg-world.com/products/rf-safety/public-rf-safety/eme-spy-evolution |title=EME SPY evolution - MVG (Satimo)}}
  • Narda Radman XT{{cite web|url=http://www.narda-sts.us/pdf_files/DataSheets/RadMan_DataSheet.pdf|title=Narda Radman XT|last=|first=|date=2011-06-06|website=|publisher=Narda-sts.us|accessdate=2012-06-06}}
  • Narda RadMan 2LT{{cite web|url=https://www.narda-sts.com/en/personal-safety-emf/radman-2-xt-/-radman-2-lt/|title=Narda Radman 2|last=|first=|date=|website=|publisher=Narda-sts.com|accessdate=2023-08-11}}
  • Narda RadMan 2XT{{cite web|url=https://www.narda-sts.com/en/personal-safety-emf/radman-2-xt-/-radman-2-lt/|title=Narda Radman 2|last=|first=|date=|website=|publisher=Narda-sts.com|accessdate=2023-08-11}}
  • Nardalert S3{{cite web|url=https://www.narda-sts.com/en/products/personal-safety-emf/|title=Nardalert S3 - Narda STS|last=|first=|date=2016-06-06|website=|publisher=Narda-sts.us|accessdate=2012-06-06}}
  • FieldSENSE60 {{Cite web |title=FieldSENSE 60 {{!}} Fieldsense |url=https://fieldsense.com/fieldsense-60-data-sheet/ |access-date=2025-01-30 |language=en-ZA}}
  • FieldSENSE 2.0{{cite web |date= |title=fieldSENSE 2.0 data sheet |url=https://fieldsense.com/fieldsense-2-data-sheet/ |url-status=live |accessdate=2025-01-30 |publisher=FieldSENSE}}
  • Public FieldSENSE
  • SafeOne Pro SI-1100XT
  • WaveMon RF-8{{Cite web|url=https://www.wavecontrol.com/rfsafety/images/data-sheets/en/WaveMon_Datasheet_EN.pdf|title=Data Sheet WaveMon RF-8|last=Broadband Personal Monitor|website=Wavecontrol}}
  • WaveMon RF-60{{Cite web|url=https://www.wavecontrol.com/rfsafety/images/data-sheets/en/WaveMon_RF-60_Datasheet_EN.pdf|title=Data Sheet WaveMon RF-60|last=60 GHz RF Personal Monitor|date=|website=Wavecontrol|access-date=}}

Gallery

File:Fieldsense60.jpg|FieldSENSE60

File:MVG - EME Guard XS 40 GHz.jpg|MVG - EME Guard XS 40 GHz.jpg

File:MVG - EME Guard XS.jpg|MVG - EME Guard XS.jpg

File:MVG-EME Spy Evolution.jpg|MVG-EME Spy Evolution

File:MVG EME Guard Plus.jpg|MVG EME Guard Plus

File:Narda RadMan Mobile 191113.jpg|Narda RadMan XT

File:Narda RadMan 2XT.png|Narda RadMan 2XT

File:Narda RadMan 2LT 191113.jpg|Narda RadMan 2LT

File:Nardalert S3 191113.jpg|Nardalert S3

File:WaveMon. RF Personal Monitor .gif|alt=Personal RF safety monitors|WaveMon RF-8 Personal RF monitor

File:Wavemon, RF Personal Monitor .png|alt=WaveMon RF-60|WaveMon RF-60 Personal RF monitor

References

[https://www.wavecontrol.com/rfsafety/images/data-sheets/en/WaveMon_Datasheet_EN.pdf]{{Reflist|30em}}

{{DEFAULTSORT:Personal RF safety monitors}}

Category:Dosimeters

Category:Radio spectrum

Radio waves

Radio waves

Category:Electromagnetic radiation