Workplace respirator testing

{{short description|Testing of respirators in real life conditions}}

File:Workplace Protection Factors Measurements.jpgRespirators, also known as respiratory protective equipment (RPE) or respiratory protective devices (RPD), are used in some workplaces to protect workers from air contaminants. Initially, respirator effectiveness was tested in laboratories, but in the late 1960s it was found that these tests gave misleading results regarding the level of protection provided.{{cite book |last1=Cralley |first1=Lesly |last2=Cralley |first2=Lester |date=1985 |title=Patty's Industrial Hygiene and Toxicology |volume=3A |edition=2 |location=New York |publisher=Willey-Interscience |pages=677–678 |isbn=0-471-86137-5}} In the 1970s, workplace-based respirator testing became routine in industrialized countries, leading to a dramatic reduction in the claimed efficacy of many respirator types and new guidelines on how to select the appropriate respirator for a given environment.{{cite book |last=Miller |first=Donald |display-authors=et al |date=1987 |url=https://www.cdc.gov/niosh/docs/87-108/ |title=NIOSH Respirator Decision Logic |publisher=National Institute for Occupational Safety and Health |page=61 |doi=10.26616/NIOSHPUB87108 |access-date=16 July 2016}}{{cite journal |last=Kirillov |first=Vladimir |display-authors=et al |date=2014 |url=http://en.toxreview.ru/magazine/?c4a=20140600 |title=Overview of Industrial Testing Outcome of Respiratory Organs Personal Protection Equipment |journal=Toksikologicheskiy Vestnik |lang=en, ru |volume=6 |issue=129 |pages=44–49 |doi=10.17686/sced_rusnauka_2014-1034 |issn=0869-7922|url-access=subscription }}

Background

File:Respirator Certification - As Vital as the Air We Breathe.webm

The invention of the first personal sampling pump in 1958 made it possible to simultaneously measure the concentrations of air pollution outside and inside a respirator mask. This was the first attempt to measure the effectiveness of respiratory protective equipment. Until the 1970s experts mistakenly believed that the protective properties of a respirator in the laboratory were not significantly different from its properties in the workplace. There were therefore no measurements of the effectiveness of respirators under production conditions, and the regions where different types of respirators could be safely used were established on the basis of laboratory tests only.

This picture began to change when it was realized in the 1960s that workers using approved respirators were still being exposed to high levels of harmful contaminants. Workplace studies have since shown that the effectiveness of respirators of all designs is much lower in real-world tests than in the laboratory. Under workplace conditions, employees must perform a variety of movements that testers in the lab do not. When the facepiece of the respirator is tightly fitted, these movements cause gaps to form between the mask and the face, decreasing the efficiency of the mask due to leakage of unfiltered air through the gaps. In addition, a small number of testers can not simulate all the variety of shapes and sizes of faces, and a 20-minute certification lab test cannot simulate all the variety of movements performed in workplaces. Testers may also be more careful about putting on and using their masks than an ordinary worker.

Evolution of workplace-based testing standards

= Initial workplace-based tests of effectiveness in the 1970s and 1980s =

A groundbreaking study in 1974 on the effectiveness of respirators used by miners simultaneously measured dust concentrations with personal samplers worn by individual miners, and using two dust collectors, without the mask. The researchers also measured the percentage of time that the miners used their respirators by attaching two thermistors to each miner (one in the facepiece, the other on the belt). Heat detection in the expired air was a sign of wearing a mask. The study defined a new measure, the "effective protection factor", that described the protection offered under real-world conditions, and reported the range of effective protection factors in four different mines.

In the steel fabrication industry, individuals performing sandblasting wore various types of hoods, usually supplied with air. Studies in 1975 found that the concentration of dust under these hoods exceeded the maximum permissible value, although air-supplied hoods offered better protection than non-air-supplied hoods. Even when sandblasting was not occurring, the level of silica dust in the atmosphere far exceeded safe levels, meaning that time workers spent outside the hood on breaks led to exposure.

In copper smelters, three commonly used types of negative pressure filtering respirators with elastomeric half-masks were examined for their ability to protect workers against concentrations of sulfur dioxide in 1976. The different respirator designs showed large variations in protectiveness, partially attributable to the comfort of the respirator design: the more comfortable masks were adjusted more tightly and were therefore more effective.

A 1979 study of the effectiveness of self-contained breathing apparatus (SCBA) in protecting firefighters against inhalation of carbon monoxide showed that intermittent usage of these respirators made them ineffective. Even continuous usage of SCBAs did not provide complete protection. This SCBA design had an air supply into the mask that supplied air "on-demand" (i.e. allowing negative pressure under the mask during inhalation). US and EU legislation now requires the use of breathing apparatus with the "pressure-demand" mode of air supply (i.e. with positive pressure under the mask during inhalation) for firefighters.

Studies also found that worker-to-worker variation in the use of respirators can have very large effects on the protection achieved. A 1980 study on inhalation exposure of cadmium workers identified a single worker who always used his respirator correctly. The protection factor for this worker was found to be 26 times higher than that for the average worker. In a study in coal mines, miners frequently removed their respirators in conditions where they perceived the dust level to be low, greatly reducing efficacy. In another study, respirators with an expected protection factor of 1000 in fact had protection factors ranging from 15 to 216. Factors affecting the level of protection achieved include the snugness of the fit of the respirator to the worker's face, and air movement in the environment.

= New measures of efficacy =

As researchers repeatedly found that the level of protection actually experienced in the workplace was much lower than the protection factors assigned to the devices after laboratory testing, it was proposed that a new expected protection factor scale should be developed, such that the real effectiveness was higher than the "expected effectiveness" with a probability of at least 90%. File:Коэффициенты защиты PAPR en.jpg with loose-fitting facepiece (hood or helmet). These data led to the assigned PF being lowered from 1000 to 25 PEL (USA), and from 1000 to 40 OEL (UK)]]

The significant differences between real and laboratory-measured effectiveness prompted the National Institute for Occupational Safety and Health (NIOSH) to release two informational messages on respirators in 1982, warning consumers about the unexpectedly low effectiveness of respirators. After extensive discussion, six new definitions of respirator protection factors were agreed upon. For example, the assigned protection factor (APF) of a respirator is the minimum protection factor the respirator must provide under the following circumstances: the respirator will be used by trained and taught workers, after individual selection of masks to fit the face of an employee, and will be used without interruption in the polluted atmosphere.{{Cite web|url=https://www.osha.gov/Publications/3352-APF-respirators.pdf|title=Assigned Protection Factors for the Revised Respiratory Protection Standard|last=Occupational Safety and Health Administration, US Department of Labor|date=2009|access-date=7 January 2020}} The actual protection experienced by a worker may be significantly lower than this and protection may vary from worker to worker.

File:Лепесток-200 старая распорка - 2.jpg filtering half-mask, viewed from the inner side of the semi-finished product. The effectiveness of this filtering facepiece was overestimated by orders of magnitude. For the period 1956 to 2015, over 6 billion respirators were produced.{{Citation needed|date=January 2020}} ]]

=Respirator efficacy at Chernobyl =

File:Médaille Tchernobyl goutte de sang.jpg medal, with traces of alpha (α) and beta (β) particles and gamma (γ) rays over a drop of blood.]]

The Chernobyl nuclear accident in 1986 led to an urgent need for protection of workers from radioactive aerosols. Approximately 300,000 negative pressure filtering facepieces of the model "Lepestok" were sent to Chernobyl in June 1986. These respirators were considered to be very effective (the declared protection factor for the most common model was 200). However, the individuals who used these respirators were exposed to excessive contamination. Just as in the case of the studies noted above, the declared protection factor was very different from the actual protection factor under real-world conditions. As seen in other workplace tests, the passage of unfiltered air through the gap between the mask and face undermined the efficiency of the respirator. However, these discoveries did not lead to a change in assessments of the effectiveness of respirators in the USSR.

= Alternatives to respirator use =

Workplace-based testing has led to extensively revised standards for the use of different designs of respirators, and has forced manufacturers to pay more attention to methods of hazard reduction such as sealing, ventilation, and automation, and to improvements in technology. For example, the National Institute for Occupational Safety and Health (USA) has provided recommendations for reducing dust concentrations in coal mines and other mines. Field measurements showed that respirators are the least reliable means of protection, with unstable and unpredictable efficacy.

Respirators are not convenient; they create discomfort and inhibit communication. The reduction of the field of view due to respirator use leads to an increase in the risk of accidents.{{Citation needed|date=January 2020}} Respirators also reinforce overheating at high air temperature. In real-world conditions, these deficiencies often lead to workers removing their respirators periodically, further reducing the efficacy of the respirator. In addition, respirators only protect workers against harmful substances entering the body through the respiratory system, whereas pollutants frequently also enter the body through the skin. Respirators thus cannot be used as substitutes for other measures that reduce the impact of air pollution on workers. However, if the respiratory system is the main way that harmful substances enter the body, and if other means of protection do not reduce the impact to an acceptable value, respirators may be a useful supplement. To maximize effectiveness, the type of respirator should be selected for the specific situation, masks should be chosen for employees personally, and workers should be trained to use the respirator effectively.{{Citation needed|date=January 2020}}

Reduction in permissible exposure limits

Legislation in industrialized countries establishes limitations on the use of all types of respirators, taking into account the results of field trials of efficacy. The permissible exposure limit [PEL] for several types of respirators was reduced. For example, for negative pressure air-purifying respirators with full face mask and high-efficiency filters, the limits were reduced from 500 PEL to 50 PEL (USA), and from 900 OEL to 40 OEL (UK); for powered air-purifying respirators with a loose-fitting facepiece (hood or helmet), limits were reduced from 1000 PEL to 25 PEL (USA); for powered air-purifying respirators with half mask, limits were reduced from 500 PEL to 50 PEL (USA); for supplied air respirators with full face mask and continuous air supply mode, limits were reduced from 100 OEL to 40 OEL (UK); for self-contained breathing apparatus respirators with air supply on demand, limits were reduced from 100 PEL to 50 PEL (USA). Filtering facepieces and negative pressure half-mask respirators were limited to 10 PEL in the USA.

class="wikitable" style="text-align:center"

|+Table. Requirements for protection factors for different types of respirators before and after workplace testing

! | Respirator type, country !! Requirements for protection factor for certification (2013) !! Permissible exposure limits prior to workplace testing (year) !! Permissible exposure limits after workplace testing (2013) !! Minimum values of measured workplace protection factors

PAPR with helmet, USA> 250 000up to 1000 PELup to 25 PEL28, 42 ...
Negative pressure air-purifying respirator with full face mask, USA

| > 250 000

| up to 100 PEL (1980)

| up to 50 PEL

| rowspan="2" | 11, 16, 17 ...

Negative pressure air-purifying respirator with full face mask, UK

| > 2000 (for gases) or >1000 (for aerosols)

| up to 900 OEL (1980)

| up to 40 OEL

Negative pressure air-purifying respirator with half mask facepiece, USA

| > 25 000

| colspan="2" | up to 10 PEL (since the 1960s)

| 2.2, 2.8, 4 ...

Self-contained breathing apparatus with air supply on demand, USA> 250 000up to 1000 PEL (1992)up to 50 PELMonitoring showed low efficiency for carbon monoxide exposure

The National Institute for Occupational Safety and Health of the USA now requires the manufacturers of high-performance RPE to perform testing at representative workplaces as a requirement for certification.

See also

References

{{reflist|refs=

{{cite journal|last=Sherwood|first=Robert|year=1966|title=On the Interpretation of Air Sampling for Radioactive Particles|journal=American Industrial Hygiene Association Journal|volume=27|issue=2|pages=98–109|issn=1542-8117|doi=10.1080/00028896609342800|pmid=5954012|url=http://www.tandfonline.com/toc/aiha20/27/2|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Sherwood|first1=Robert |last2=Greenhalgh|first2=D.M.S.|year=1960|title=A Personal Air Sampler|journal=The Annals of Occupational Hygiene|volume=2|issue=2|pages=127–132|issn=0003-4878|doi=10.1093/annhyg/2.2.127|pmid=14445915 |url=http://annhyg.oxfordjournals.org/content/2/2/|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Harris|first1=H.E.|last2=DeSieghardt|first2=W.C.|last3=Burgess|first3=W. A.|last4=Reist|first4=Parker|year=1974|title=Respirator Usage and Effectiveness in Bituminous Coal Mining Operations|journal=American Industrial Hygiene Association Journal|volume=35|issue=3|pages=159–164|issn=1542-8117|doi=10.1080/0002889748507018|pmid=4522752|language=en}}

{{cite journal|last1=Behzad|first1=Samimi|last2=Neilson|first2=Arthur|last3=Weill|first3=Hans|last4=Ziskind|first4=Morton|year=1975|title=The Efficiency of Protective Hoods Used by Sandblasters to Reduce Silica Dust Exposure|journal=American Industrial Hygiene Association Journal|volume=36|issue=2|pages=140–148|issn=1542-8117|doi=10.1080/0002889758507222|pmid=167570|language=en}}

{{cite journal|last1=Moore|first1=David|last2=Smith|first2=Thomas|year=1976|title=Measurement of protection factors of chemical cartridge, half-mask respirators under working conditions in a copper smelter|journal=American Industrial Hygiene Association Journal|volume=37|issue=8|pages=453–458|issn=1542-8117|doi=10.1080/0002889768507495|pmid=970320|language=en}}

{{cite journal|last=Levin|first=Marshal|year=1979|title=Respirator use and protection from exposure to carbon monoxide|journal=American Industrial Hygiene Association Journal|volume=40|issue=9|pages=832–834|issn=1542-8117|doi=10.1080/15298667991430361|pmid=517443|language=en}}

{{cite journal|last1=Smith|first1=Thomas|last2=Ferrel|first2=Willard|last3=Varner|first3=Michael|last4=Putnam|first4=Robert|year=1980|title=Inhalation exposure of cadmium workers: effects of respirator usage|journal=American Industrial Hygiene Association Journal|volume=41|issue=9|pages=624–629|issn=1542-8117|doi=10.1080/15298668091425400|pmid=7457382|url=http://www.tandfonline.com/toc/aiha20/41/9|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Myers|first1=Warren |last2=Peach|first2=M.J. III|year=1983|title=Performance measurements on a powered air-purifying respirator made during actual field use in a silica bagging operation |journal=The Annals of Occupational Hygiene|volume=27 |issue=3 |pages=251–259 |issn=0003-4878|doi=10.1093/annhyg/27.3.251|pmid=6314865 |url=https://www.tandfonline.com/doi/abs/10.1080/15298668391405670|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Que Hee|first1=Shane|last2=Lawrence|first2=Philip|year=1983|title=Inhalation Exposure of Lead in Brass Foundry Workers: The Evaluation of the Effectiveness of a Powered Air-Purifying Respirator and Engineering Controls|journal=American Industrial Hygiene Association Journal|volume=44|issue=10|pages=746–751|issn=1542-8117|doi=10.1080/15298668391405670|pmid=6650396|url=http://www.tandfonline.com/toc/aiha20/44/10|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Lenhart|first1=Steven |last2=Campbel|first2=Donald|year=1984|title=Assigned protection factors for two respirators types based upon workplace performance testing |journal=The Annals of Occupational Hygiene|volume=28 |issue=2 |pages=173–182 |issn=0003-4878|doi=10.1093/annhyg/28.2.173|pmid=6476685 |url=http://annhyg.oxfordjournals.org/content/28/2/|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Myers|first1=Warren|last2=Peach III|first2=Michael|last3=Cutright|first3=Ken|last4=Iskander|first4=Wafik|year=1984|title=Workplace Protection Factor Measurements on Powered Air-Purifying Respirators at a Secondary Lead Smelter: Results and Discussion|journal=American Industrial Hygiene Association Journal|volume=45|issue=10|pages=681–688|issn=1542-8117|doi=10.1080/15298668491400449|pmid=6496315|language=en}}

{{cite book|last=Miller|first=Donald|display-authors=etal|title=NIOSH Respirator Decision Logic|url=https://www.cdc.gov/niosh/docs/87-108/|access-date=16 July 2016|series=DHHS (NIOSH) Publication No. 87-108|year=1987|publisher=National Institute for Occupational Safety and Health|language=en|page=61|doi=10.26616/NIOSHPUB87108}}

{{cite journal|last1=Zhuang|first1=Ziqing|last2=Coffey|first2=Christopher|last3=Campbell|first3=Donald|last4=Lawrence|first4=Robert|last5=Myers|first5=Warren|year=2003|title=Correlation Between Quantitative Fit Factors and Workplace Protection Factors Measured in Actual Workplace Environments at a Steel Foundry|journal=American Industrial Hygiene Association Journal|volume=64|issue=6|pages=730–738|issn=1542-8117|doi=10.1080/15428110308984867|pmid=14674806 |url=http://www.tandfonline.com/toc/aiha20/64/6|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Myers|first1=Warren|last2=Peach III|first2=Michael|last3=Cutright|first3=Ken|last4=Iskander|first4=Wafik|year=1986|title=Field Test of Powered Air-Purifying Respirators at a Battery Manufacturing Facility|journal=Journal of the International Society for Respiratory Protection|volume=4 |issue=1 |pages=62–89 |issn=0892-6298|url=http://www.isrp.com|language=en}}

{{cite journal|last1=Johnson|first1=Alan|last2=Myers|first2=Warren|last3=Colton|first3=Craig|last4=Birkner|first4=J.S.|last5=Campbell|first5=C.E.|year=1992|title=Review of respirator performance testing in the workplace: issues and concerns|journal=American Industrial Hygiene Association Journal|volume=53|issue=11|pages=705–712|issn=1542-8117|doi=10.1080/15298669291360409|pmid=1442561|url=http://www.tandfonline.com/toc/aiha20/53/11|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Lof|first1=Agneta|last2=Brohede|first2=Christina|last3=Gullstrand|first3=Elisabeth|last4=Lindstrom|first4=Karin|last5=Sollenberg|first5=Jan|last6=Wrangskog|first6=Kent|last7=Hagberg|first7=Mats|last8=Hedman|first8=Birgitta Kolmodin|year=1993|title=The effectiveness of respirators measured during styrene exposure in a plastic boat factory|journal=International Archives of Occupational and Environmental Health|volume=65|issue=1|pages=29–34|issn=0340-0131|doi=10.1007/BF00586055|pmid=8354572|bibcode=1993IAOEH..65...29L |s2cid=36237447 |url=https://link.springer.com/journal/420/65/1/page/1|access-date=16 July 2016|language=en|url-access=subscription}}

{{cite journal|last=Ming-Tsang|first=Wu|year=2002|title=Assessment of the Effectiveness of Respirator Usage in Coke Oven Workers|journal=American Industrial Hygiene Association Journal|volume=63|issue=1|pages=72–75|issn=1542-8117|doi=10.1080/15428110208984694|pmid=11843430|url=http://www.tandfonline.com/toc/aiha20/63/1|access-date=10 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Clayton|first1=Mike |last2=Bancroft|first2=B. |last3=Rajan-Sithamparanadarajah|first3=Bob |year=2002|title=A Review of Assigned Protection Factors of Various Types and Classes of Respiratory Protective Equipment with Reference to their Measured Breathing Resistances |journal=The Annals of Occupational Hygiene|volume=46 |issue=6 |pages=537–547 |issn=0003-4878|doi=10.1093/annhyg/mef071|pmid=12176769 |language=en|doi-access=}}

{{cite journal|last1=Janssen|first1=Larry |last2=Bidwell|first2=Jeanne|year=2007|title=Performance of a Full Facepiece, Air-Purifying Respirator Against Lead Aerosols in a Workplace Environment |journal=Journal of Occupational and Environmental Hygiene|volume=4 |issue=2 |pages=123–128 |issn=1545-9632|doi=10.1080/15459620601128845|pmid=17175515 |s2cid=15928287 |url=http://www.tandfonline.com/toc/uoeh20/4/2|access-date=15 July 2016|language=en|url-access=subscription}}

{{cite journal|last1=Chang|first1=Fu-Kuei|last2=Chen|first2=Mei-Lien|last3=Cheng|first3=Shu-Fang|last4=Shih|first4=Tung-Sheng|last5=Mao|first5=I-Fang|year=2007|title=Evaluation of dermal absorption and protective effectiveness of respirators for xylene in spray painters|journal=International Archives of Occupational and Environmental Health|volume=81|issue=2|pages=145–150|issn=0340-0131|doi=10.1007/s00420-007-0197-9|pmid=17492305|bibcode=2007IAOEH..81..145C |s2cid=24442412 |url=https://link.springer.com/journal/420/81/2/page/1|access-date=16 July 2016|language=en|url-access=subscription}}

{{cite book |title=British Standard BS 4275:1997 "Guide to implementing an effective respiratory protective device programme"|edition=3rd |date=1997 |publisher=British Standards Institution|location=London|language=en|isbn=0-580-28915 X}}

{{cite book|last1=Petryanov|first1=Igor|last2=Kashcheev|first2=Victor|display-authors=etal|title=["Lepestok". Filterring facepieces]|edition=2|year=2015|publisher=Nauka|location=Moscow|language=ru|isbn=978-5-02-039145-1 |page=320}}

{{cite book|last1=Hoover|first1=Mark D.|last2=Lackey|first2=Jack R.|last3=Vargo|first3=George J. |title=Independent Evaluation of The Lepestok Filtering Facepiece Respirator|chapter-url=http://www.pnl.gov/main/publications/external/technical_reports/pnnl-13581.pdf|access-date=16 July 2016|series=PNNL-13581; LRRI-20001202|year=2001|publisher=Lovelace Respiratory Research Institute, Pacific Northwest National Laboratory (U.S. Department of Energy)|location=Albuquerque, NM|language=en|pages=13–20|chapter=Results and Discussion}}

{{cite book|last1=Ogorodnikov |first1=Boris|last2=Pasukhin |first2=Edward|title=[Radioactive aerosols of the object "Ukryttya" (a review). Part 5. Means for sampling and analyses of aerosols. Radioactive aerosols in lungs]|chapter-url=http://www.iaea.org/inis/collection/NCLCollectionStore/_Public/39/116/39116456.pdf|access-date=16 July 2016|series=Preprint 06-6|year=2006|publisher=National Academy of Sciences of Ukraine. Institute for safety problems of nuclear power plants|location=Chernobyl|language=ru|pages=10–28|chapter=[Respiratory protective devices]}}

{{cite book|last1=Galushkin|first1=B.A.|last2=Gorbunov|first2=S.V.|editor=Victor Kashcheev |title=[Abstracts of the III All-Union Conference "Experimental physiology, hygiene and personal protection of the person"]|year=1990|publisher=The Ministry of Health of the USSR, Institute of Biophysics|location=Moscow|language=ru|pages=11–12|chapter=[Experimental studies to determine the protection factor of the filtering facepiece respirator "Lepestok-200" during emergency operations at the Chernobyl nuclear power plant ]}}

{{cite book|last1=Galushkin|first1=B.A.|last2=Gorbunov|first2=S.V.|editor=Victor Kashcheev |title=[Abstracts of the III All-Union Conference "Experimental physiology, hygiene and personal protection of the person"]|year=1990|publisher=The Ministry of Health of the USSR, Institute of Biophysics|location=Moscow|language=ru|pages=12–13|chapter=[The efficiency of a filtering matherial ФПП-15-1.5]}}

{{cite book|last1=Cecala|first1=Andrew B.|last2=Volkwein|first2=Jon C.|last3=Thomas|first3=Edward D.|author4=Charles W. Urban|title=Protection Factors of the Airstream Helmet|series=Bureau of Mines Report No. 8591|year=1981|language=en|page=10}}

{{cite book|editor=Nancy J. Bollinger, Robert H. Schutz|title=NIOSH Guide to Industrial Respiratory Protection|url=https://www.cdc.gov/niosh/docs/87-116/|series=DHHS (NIOSH) Publication No 87-116|year=1987|publisher=National Institute for Occupational Safety and Health|location=Cincinnati, Ohio|language=en|page=305|doi=10.26616/NIOSHPUB87116}}

{{cite book|last1=Bollinger|first1=Nancy|last2=Campbell|first2=Donald |last3=Coffey|first3=Christopher |others=NIOSH Respirator Policy Group; Heinz Ahlers, Roland BerryAnn, Frank Hearl, Richard Metzler, Teresa Seitz, Douglas Trout and Ralph Zumwalde|title=NIOSH Respirator Selection Logic|chapter-url=https://www.cdc.gov/niosh/docs/2005-100/|series=DHHS (NIOSH) Publication No. 2005-100|year=2004|publisher=The National Institute for Occupational Safety and Health (NIOSH) |location=Cincinnati, OH|language=en|pages=3–16|chapter=III. Respirator Selection Logic Sequence|doi=10.26616/NIOSHPUB2005100 }}

OSHA standard [http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=12716 29 CFR 1910.134] "Respiratory Protection"

NIOSH standard [http://cfr.regstoday.com/42cfr84.aspx 42 Code of Federal Register Part 84 ] "Respiratory Protective Devices"

{{cite book|last1=Colinet|first1=Jay F.|last2=Rider|first2=James P.|last3=Listak|first3=Jeffrey M.|others=John A. Organiscak, and Anita L. Wolfe|title=Best Practices for Dust Control in Coal Mining|url=https://www.cdc.gov/niosh/mining/works/coversheet861.html|access-date=16 July 2016|series=Information Circular 9517. DHHS (NIOSH) Publication No. 2010–110|year=2010|publisher=National Institute for Occupational Safety and Health|location=Pittsburgh, PA - Spokane, WA|language=en|page=84}}

{{cite book|last1=Cecala|first1=Andrew B.|last2=O'Brien|first2=Andrew D.|last3=Schall|first3=Joseph|others=Jay F. Colinet, William R. Fox, Robert J. Franta, Jerry Joy, Wm. Randolph Reed, Patrick W. Reeser, John R. Rounds, Mark J. Schultz|title=Dust Control Handbook for Industrial Minerals Mining and Processing|url=https://www.cdc.gov/niosh/mining/works/coversheet1765.html|access-date=16 July 2016|series=Report of Investigations 9689. DHHS (NIOSH) Publication No. 2012–112|year=2012|publisher=National Institute for Occupational Safety and Health|location=Pittsburgh, PA; Spokane, WA|language=en|page=314}}

{{cite book|last1=Howie|first1=Robin M. |last2=Walton|first2=W.H.|editor=Brian Ballantyne & Paul Schwabe|title=Respiratory Protection. Principles and Applications|year=1981|publisher=Chapman & Hall|location=London, New York|language=en|isbn=978-0-412-22750-9|pages=287–298|chapter=Practical Aspects of the Use of Respirators in the British Coal Mines}}

}}

Category:Respirators