laser Doppler imaging
{{Infobox diagnostic
| name = Laser Doppler imaging
| image = LaserDopplerHolographyRetinaONH.gif
| alt =
| caption = Microangiography of the optic disc region of the human retina, by laser Doppler imaging. The image was rendered computationally by optical wave propagation and measurement of optical fluctuations.
| pronounce =
| purpose = measure blood flow in eye
| test of =
| based on = Digital holography
| synonyms =
| reference_range =
| calculator =
| DiseasesDB =
| ICD10 =
| ICD9 =
| ICDO =
| MedlinePlus =
| eMedicine =
| MeshID =
| OPS301 =
| LOINC =
}}
Laser Doppler imaging (LDI) is an imaging method that uses a laser beam to image live tissue. When the laser light reaches the tissue, the moving blood cells generate Doppler components in the reflected (backscattered) light. The light that comes back is detected using a photodiode that converts it into an electrical signal. Then the signal is processed to calculate a signal that is proportional to the tissue perfusion in the imaged area. When the process is completed, the signal is processed to generate an image that shows the perfusion on a screen.{{Cite journal|doi = 10.1109/10.222322|title = Laser Doppler perfusion imaging by dynamic light scattering|year = 1993|last1 = Wardell|first1 = K.|last2 = Jakobsson|first2 = A.|last3 = Nilsson|first3 = G.E.|journal = IEEE Transactions on Biomedical Engineering|volume = 40|issue = 4|pages = 309–316|pmid = 8375866|s2cid = 23260143}}
The laser Doppler effect was first used to measure microcirculation by Stern M.D. in 1975.{{Cite journal|last1=Leahy|first1=M.J.|last2=de Mul|first2=F.F.M.|last3=Nilsson|first3=G.E.|last4=Maniewski|first4=R.|date=1999-06-01|title=Principles and practice of the laser-Doppler perfusion technique|journal=Technology and Health Care|volume=7|issue=2–3|pages=143–162|doi=10.3233/THC-1999-72-306|pmid=10463304|url=https://ris.utwente.nl/ws/files/6769274/thc_1999_7-2,3_THC103.pdf }}{{Cite journal|last=Stern|first=M. D.|date=March 1975|title=In vivo evaluation of microcirculation by coherent light scattering|journal=Nature|language=en|volume=254|issue=5495|pages=56–58|doi=10.1038/254056a0|pmid=1113878|bibcode=1975Natur.254...56S|s2cid=4181767}} It is used widely in medicine, some representative research work about it are these: {{Cite journal|last1=Leutenegger|first1=Marcel|last2=Martin-Williams|first2=Erica|last3=Harbi|first3=Pascal|last4=Thacher|first4=Tyler|last5=Raffoul|first5=Wassim|last6=André|first6=Marc|last7=Lopez|first7=Antonio|last8=Lasser|first8=Philippe|last9=Lasser|first9=Theo|date=2011-06-01|title=Real-time full field laser Doppler imaging|journal=Biomedical Optics Express|language=en|volume=2|issue=6|pages=1470–1477|doi=10.1364/BOE.2.001470|doi-access=free|pmc=3114216|pmid=21698011}}{{Cite journal|last1=Grothusen|first1=John R.|last2=Schwartzman|first2=Robert J.|date=September 2011|title=Laser Doppler imaging: usefulness in chronic pain medicine|journal=Pain Physician|volume=14|issue=5|pages=491–498|doi=10.36076/ppj.2011/14/491|pmid=21927054|doi-access=free}}{{Cite journal|date=1999-05-01|title=Laser Doppler Imaging—A New Technique for Quantifying Microcirculatory Flow in Patients with Primary Raynaud's Phenomenon and Systemic Sclerosis|journal=Microvascular Research|language=en|volume=57|issue=3|pages=284–291|doi=10.1006/mvre.1998.2124|last1=Clark|first1=Stuart|last2=Campbell|first2=Fiona|last3=Moore|first3=Tonia|last4=Jayson|first4=Malcolm I.V.|last5=King|first5=Terence A.|last6=Herrick|first6=Ariane L.|pmid=10329254}}
Use in ophthalmology
The eye offers a unique opportunity for the non-invasive exploration of cardiovascular diseases. LDI by digital holography can measure blood flow in the retina and choroid.{{Cite journal|doi = 10.1364/BOE.9.004113|doi-access=free|title = In vivo laser Doppler holography of the human retina|year = 2018|last1 = Puyo|first1 = L.|last2 = Paques|first2 = M.|last3 = Fink|first3 = M.|last4 = Sahel|first4 = J.-A.|last5 = Atlan|first5 = M.|journal = Biomedical Optics Express|volume = 9|issue = 9|pages = 4113–4129|pmid = 30615709|pmc = 6157768|arxiv = 1804.10066}} In particular, the choroid is a highly vascularized tissue supplying the retinal pigment epithelium and photoreceptors. Yet investigating the anatomy and flow of the choroid remains challenging. LDI provides high-contrast visualization of local blood flow in choroidal vessels in humans, with a spatial resolution comparable to state-of-the-art indocyanine green angiography.{{Cite journal|doi = 10.1364/BOE.10.000995|arxiv=2106.00608 |doi-access=free|title = Choroidal vasculature imaging with laser Doppler holography|year = 2019|last1 = Puyo|first1 = Léo|last2 = Paques|first2 = Michel|last3 = Fink|first3 = Mathias|last4 = Sahel|first4 = José-Alain|last5 = Atlan|first5 = Michael|journal = Biomedical Optics Express|volume = 10|issue = 2|pages = 995–1012|pmid = 30800528|pmc = 6377881}} Differences in blood pressure drive the flow of blood throughout the circulation. The rate of mean blood flow depends on both blood pressure and the hemodynamic resistance to flow presented by the blood vessels. LDI can enable mapping of the local arterial resistivity index, and the possibility to perform unambiguous identification of retinal arteries and veins on the basis of their systole-diastole variations, and reveal ocular hemodynamics in human eyes.{{Cite journal|doi = 10.1364/BOE.10.004942|arxiv=2106.00634|doi-access=free|title = Waveform analysis of human retinal and choroidal blood flow with laser Doppler holography|year = 2019|last1 = Puyo|first1 = Léo|last2 = Paques|first2 = Michel|last3 = Fink|first3 = Mathias|last4 = Sahel|first4 = José-Alain|last5 = Atlan|first5 = Michael|journal = Biomedical Optics Express|volume = 10|issue = 10|pages = 4942–4963|pmid = 31646021|pmc = 6788604}}
Measurement of surface waves on the skin
File:Hand Emmanuel gain6 color 9 35.gif: laser Doppler imaging of pulse waves on the surface of the hand.]]
The local velocity of blood flow measured by laser Doppler holography in the digit (photoplethysmogram) and the eye fundus has a pulse-shaped profile with time. These remote pulse wave measurements can be done clinically to reveal hemodynamics in arteries and veins and can be readily measured non-invasively. Principal component analysis of digital holograms{{cite arXiv |eprint = 2004.00923|last1 = Puyo|first1 = Leo|last2 = Bellonnet-Mottet|first2 = Loic|last3 = Martin|first3 = Antoine|last4 = Te|first4 = Francois|last5 = Paques|first5 = Michel|last6 = Atlan|first6 = Michael|title = Real-time digital holography of the retina by principal component analysis|year = 2020|class = physics.med-ph}} is an efficient way of performing temporal demodulation of digital holograms reconstructed from on-axis interferograms and can be used to reveal surface waves on the hand.
Use in obstetrics and gynaecology
LDI provides a direct measure of female sexual response that does not require genital contact; signals are gathered at a depth of two to three millimetres below the skin's surface.{{Cite journal|doi = 10.1111/j.1743-6109.2009.01326.x|title = Laser Doppler Imaging of Genital Blood Flow: A Direct Measure of Female Sexual Arousal|year = 2009|last1 = Waxman|first1 = Samantha E.|last2 = Pukall|first2 = Caroline F.|journal = The Journal of Sexual Medicine|volume = 6|issue = 8|pages = 2278–2285|pmid = 19493290}} Two studies have suggested that LDI is a valid measure of female sexual arousal.{{Cite journal|doi = 10.1111/j.1471-0528.2006.00894.x|title = Short communication: Laser Doppler perfusion imaging: A method for measuring female sexual response|year = 2006|last1 = Styles|first1 = SJ|last2 = MacLean|first2 = AB|last3 = Reid|first3 = WMN|last4 = Sultana|first4 = SR|journal = BJOG: An International Journal of Obstetrics & Gynaecology|volume = 113|issue = 5|pages = 599–601|pmid = 16637901|s2cid = 31409255}} Waxman and Pukall showed that LDI has discriminant validity; that is, it can differentiate sexual response from neutral, positive, and negative mood induced states. Compared to vaginal photoplethysmography (VPG), LDI is advantageous because it does not require genital contact. Also, LDI provides a direct measure of vasocongestion and has an absolute unit of measurement, consisting of flux or units of blood flow. The disadvantages of LDI are that it cannot provide a continuous measure of sexual response and the laser Doppler perfusion imager is much more costly that other methods of genital sexual arousal assessment, such as VPG.
See also
References
{{Reflist}}
External links
{{Commons category|Laser-doppler flowmetry}}
- [http://www.holomap.com/lda.htm LDA/LDV principle] {{Webarchive|url=https://web.archive.org/web/20110712214301/http://www.holomap.com/lda.htm |date=2011-07-12 }}
- [http://www.efunda.com/designstandards/sensors/laser_doppler/laser_doppler_intro.cfm LDV overview]