In the United States and Canada, lamps are typically identified by a code such as FxxTyy, where F is for fluorescent, and the first number (xx) indicates either the power in watts for bi-pin lamps, length in inches for single-pin and high-output lamps, and for circular bulbs, the diameter of the circular bulb. The T indicates that the shape of the bulb is tubular, and the last number (yy) is the diameter in eighths of an inch (sometimes in millimeters, rounded up to the nearest millimeter). Typical diameters are T12 or T38 ({{cvt|1+1/2|in|disp=or}}) for larger, often less efficient lamps, T8 or T26 ({{cvt|1|in|disp=or}}) for smaller and often energy-saving lamps, and T5 or T16 ({{cvt|5/8|in|disp=or}}) for very small lamps, which may even operate from a battery-powered device.

class="wikitable"

|+ Fluorescent tube diameter designation comparison

colspan=2 rowspan=2 | Designation

! colspan=2 | Tube diameter

! colspan=2 | Extra

(in)(mm)

! Socket

! Notes

T2

|

|{{frac|1|4}} approx.

| 7

| WP4.5×8.5d

|

T4

|

| {{frac|1|2}}

| 12.7

| G5 bi-pin

| Slim lamps. Power ratings and lengths not standardized (and not the same) between different manufacturers

T5

| T16

| {{frac|5|8}}

| 15.9

|

  • G5 bi-pin
  • 2GX13 quad-pin
  • G10q quad-pin

|

  • Original 4–13 W miniature fluorescent range from 1950s or earlier.Funke and Oranje, "Gas Discharge Lamps"; N.V Philips' Gloeilampenfabrieken (1951)
  • Two newer ranges, high-efficiency (HE) 14–35 W, and high-output (HO) 24–80 W, introduced in the 1990s.{{cite web|url=https://www.ecmweb.com/archive/article/20885420/the-t5-fluorescent-lamp-coming-on-strong|title=The T5 Fluorescent Lamp: Coming on Strong|date=2003-09-01|accessdate=2020-02-20}}
  • Panasonic's range of FHL fluorescent tubes in 18W, 27W, and 36W varieties for the Japanese market.
  • Circular fluorescent tubes.
  • Thorn/General Electric 2D fluorescent lamps and other similar lamps from various manufacturers.
T6

|

|{{frac|3|4}}

|19.05

|

  • Fa8 single-pin
  • G10q quad-pin

|

  • Single-pin fluorescent lamps.
  • Thorn/General Electric 2D fluorescent lamps and other similar lamps from various manufacturers.
T8

| T26

| 1

| 25.4

|

  • G13 bi-pin
  • Fa8 single-pin
  • R17d recessed double contact

| One of the first diameters of fluorescent lamps, with the 15W T8 and 30W T8 having been introduced in 1938.{{cite web|url=http://home.frognet.net/~ejcov/thayer.html|title=Covington, E. J. The Story Behind This Account of Fluorescent Lamp Development|accessdate=2008-09-28|archive-url=https://web.archive.org/web/20070324195444/http://home.frognet.net/~ejcov/thayer.html|archive-date=24 March 2007|url-status=dead}} The European energy-saving krypton T8 lamps were introduced by Thorn EMI during the 1970s.{{Cite web |title=The Fluorescent Lamp – Gas Fillings |url=http://www.lamptech.co.uk/Documents/FL%20Gases.htm |access-date=2023-08-30 |website=lamptech.co.uk}} The North American energy-saving argon T8 lamps weren't introduced until the 1980s.{{cite web|url=http://ateam.lbl.gov/Design-Guide/DGHtm/t.8lampretrofits.htm|title=Lawrence Berkeley National Laboratory: T-8 lamp retrofits|accessdate=2008-09-28|archive-date=16 September 2008|archive-url=https://web.archive.org/web/20080916091343/http://ateam.lbl.gov/Design-Guide/DGHtm/t.8lampretrofits.htm|url-status=dead}}

T9

| T29

| {{frac|1|1|8}}

| 28.6

|

  • G10q quad-pin
  • G13 bi-pin

|

  • Circular fluorescent tubes
  • Some linear tubes
T10

|

| {{frac|1|1|4}}

| 31.75

|

  • G13 bi-pin
  • G10q quad-pin

|

  • High-lumen retrofit lamps for 40W T12 lamps in North America.
  • Popular tube diameter in Japan
  • Circular 32W and 40W T10 lamps (Older versions of the 32W and 40W T9 lamps)
T12

| T38

| {{frac|1|1|2}}

| 38.1

|

  • G13 bi-pin
  • Fa8 single-pin
  • R17d recessed double contact

| One of the first diameters of fluorescent lamps, with the 15W T12 and 20W T12 having been introduced in 1938. These aren't as efficient as newer lamp options.{{cite web|url=http://ateam.lbl.gov/Design-Guide/DGHtm/historyandproblemsoft12fluorescentlamps.htm|title=Lawrence Berkeley National Laboratory: History and problems of T12 fluorescent lamps|accessdate=2008-09-28|archive-date=16 September 2008|archive-url=https://web.archive.org/web/20080916091349/http://ateam.lbl.gov/Design-Guide/DGHtm/historyandproblemsoft12fluorescentlamps.htm|url-status=dead}}

T17

|

| {{frac|2|1|8}}

| 54

| G20 Mogul bi-pin

| Large size for 90W T17 (preheat) and 40W T17 (instant start)

PG17

|

| {{frac|2|1|8}}

| 54

| R17d Recessed double contact

| General Electric's Power Groove tubes

For T2–T12 and T17, the number indicates the tube diameter in {{frac|1|8}} inches, e.g. T2 → {{frac|2|8}} in and T17 → {{frac|17|8}} in. Whereas for T16 and T26–T38, the number indicates the approximate tube diameter in millimeters.

=Reflectors=

File:Reflectorlamp.gif

Some lamps have an internal opaque reflector. Coverage of the reflector ranges from 120° to 310° of the lamp's circumference.

Reflector lamps are used when light is only desired to be emitted in a single direction, or when an application requires the maximum amount of light. For example, these lamps can be used in tanning beds or in backlighting electronic displays. An internal reflector is more efficient than standard external reflectors. Another example is color matched aperture lights (with about 30° of opening) used in the food industry for robotic quality control inspection of cooked goods.

Aperture lamps have a clear break in the phosphor coating, typically of 30°, to concentrate light in one direction and provide higher brightness in the beam than can be achieved by uniform phosphor coatings. Aperture lamps include reflectors over the non-aperture area. Aperture lamps were commonly used in photocopiers in the 1960s and 1970s where a bank of fixed tubes was arranged to light up the image to be copied, but are rarely found nowadays. Aperture lamps can produce a concentrated beam of light suitable for edge-lit signs.

=Single-pin lamps=

Single-pin lamps (Also generically called "Slimline" in the United States) operate on an instant start ballast in the United States and Canada or on a series choke without a starter in 220-240V countries.

=High-output/very high output lamps=

High-output lamps are brighter and are driven at a higher electric current. They have a recessed double contact (R17d) base on each end, rather than a standard bi-pin base, which prevents them from being installed into the wrong fixture. Since about the early to mid-1950s to today, General Electric has developed and improved the Power Groove lamp. These lamps are recognizable by their large diameter ({{cvt|2+1/8|in|disp=or}}) and grooved tube shape.

=Colors=

Colors using a halophosphate formulation are usually indicated by WW for warm white, W for (neutral) white, CW for cool white, and D for the bluish daylight white.

Philips and Osram use numeric color codes for tri-phosphor and multi-phosphor colors. The first digit indicates the color rendering index (CRI) of the lamp. If the first digit on a lamp says 8, then the CRI of that lamp will be approximately 85. The last two digits indicate the color temperature of the lamp in kelvins (K). For example, if the last two digits on a lamp say 41, that lamp's color temperature will be 4100 K, which is a common tri-phosphor cool white fluorescent lamp.

BL is used for ultraviolet lamps commonly used in bug zappers. BLB is used for blacklight-blue lamps employing a Wood's glass envelope to filter out most visible light, commonly used in nightclubs. Other non-standard designations apply for plant lights or grow lights.

class="wikitable"

! colspan="6" | Calcium halophosphate tubes

Japanese color code

! Numeric color code

!Alphabetic color code

! Color

! Approximate CRI

! Color temperature (K)

N/A

| 29

|WW

| Warm white

| ≈52

| 3000

WW

| 35

|W

| White

| ≈56

| 3500

W

| 33

|CW

| Cool White

| ≈62

| 4000-4300

N/A

| 25

|N/A

| Neutral/Universal White

| ≈75

| 4000

N

|N/A

|N/A

| Natural Daylight

| ≈70

| 5000

D

| 54

|D

| Daylight

| ≈75

| 6500

colspan="6" | Deluxe halophosphate tubes
Japanese color code

! Numeric color code

!Alphabetic color code

! Color

! Approximate CRI

! Color temperature (K)

L-EDL

| 27

|N/A

| Deluxe Extra Warm White

| ≈95

| 2700

N/A

|N/A

|SW

|GE Soft White (Lower-CRI WWX)

|≈77

|3000

N/A

| 32

|WWX

| Deluxe Warm White

| ≈87

| 3000

N/A

|N/A

|WX

|Sylvania White Deluxe

|≈85

|3500

N/A

| 79

|N

| Natural

| ≈90

| 3600

N/A

| 34

|N/A

| Deluxe White

| ≈85

| 3850

W-SDL

| 38

|CWX

| Deluxe Cool White/{{proper name|Kolor-rite}}

| ≈90

| 4000

N/A

|N/A

|C41

|GE Cool White Utility (Enhanced CWX)

|≈87

|4100

N-SDL, N-EDL

|N/A

|C50/DSGN50

|GE Chroma 50/Philips Colortone 50/Sylvania Design 50

|≈90-99

|5000

D-SDL, D-EDL

| 55

|DX

| Deluxe Daylight/Northlight/Colour Matching

| ≈88-98

| 6500

N/A

|N/A

|C75

|GE Chroma 75/Philips Colortone 75

|≈92

|7500

colspan="6" |700-series tubes (Calcium halophosphate and rare-earths tri-phosphor blend)
Numeric color code

!Alphanumeric color code

!Color

!Approximate CRI

! colspan="2" |Color temperature (K)

730

|SP30/D30/TL730

|Warm White

|≈75

| colspan="2" |3000

735

|SP35/D35/TL735

|Neutral White

|≈75

| colspan="2" |3500

741

|SP41/D41/TL741

|Cool White

|≈75

| colspan="2" |4100

750

|SP50/TL750

|Natural Daylight

|≈75

| colspan="2" |5000

765

|SP65/TL765

|Cool Daylight

|≈75

| colspan="2" |6500

colspan="6" | 800-series rare-earth tri-phosphor tubes
Japanese Color Code

!Numeric color code

!Color

!Approximate CRI

! colspan="2" |Color temperature (K)

ELX

|825

|Sunset White

|≈85

| colspan="2" |2500

ELR, ELC

|827, 828

|Extra Warm white

|≈85

| colspan="2" |2700, 2800

EX-L, EL, ELK

|830

|Warm White

|≈85

| colspan="2" |3000

ELW

|832

|Warm White

|≈85

| colspan="2" |3200

EX-WW, EWW

|835

|Neutral White

|≈85

| colspan="2" |3500

EW38

|838

|Neutral White

|≈85

| colspan="2" |3800

EX-W, EW

|840, 841, 842

|Cool White

|≈85

| colspan="2" |4000, 4100, 4200

EX-N, EN

|850

|Natural Daylight

|≈85

| colspan="2" |5000

ENW, ENM, ENC

|852, 853

|Natural Daylight

|≈85

| colspan="2" |5200, 5300

ENK

|855

|Natural Daylight

|≈85

| colspan="2" |5500

ENX

|858

|Natural Daylight

|≈85

| colspan="2" |5800

EDW

|862

|Cool Daylight

|≈85

| colspan="2" |6200

EX-D, ED

|865, 867

|Cool Daylight

|≈85

| colspan="2" |6500, 6700

ECW, EDK, EDC

|872, 874

|Cool Daylight

|≈85

| colspan="2" |7200, 7400

EDF, EDX

|880

|Skywhite

|≈85

| colspan="2" |8000

colspan="6" | 900-series deluxe rare-earth phosphors tubes
colspan="2" | Numeric color code

! Color

! Approximate CRI

! colspan="2" | Color temperature (K)

colspan="2" | 930

| Warm white

| ≈95

| colspan="2" | 3000

colspan="2" | 941

| Cool white

| ≈95

| colspan="2" | 4100

colspan="2" | 950

| Natural Daylight

| ≈98

| colspan="2" | 5000

colspan="2" | 965

| Cool daylight

| ≈95

| colspan="2" | 6500

colspan="6" | Special purpose tubes
Numeric code

!Alphabetic Code

! Fluorescent

lamp type

! colspan="3" | Notes

05

|N/A

| Germicidal lamps

| colspan="3" | No phosphors used in these lamps at all, and the enveplope is made of fused quartz instead of glass.

In the American lamp code, the F as in FxxTyy is replaced by a G as in GxxTyy, indicating that it's a germicidal lamp.

08

|BLB

| Black-Light Blue lamps

| colspan="3" |These lamps are similar to the regular black light lamps, except they use wood's glass as a filter to reduce the amount of visible light emitted. These lamps are used for fluorescence effects where less visible light is ideal.

09

|N/A

| Sun-tanning lamps

| colspan="3" |These lamps produce wide or narrow band UV-B radiation

10

|BL

|Black-Light lamps

| colspan="3" |Black light lamps give off long-wave UV-A radiation of around 350-400 nm. They are often used to attract insects to traps. Unlike black light blue lamps, these lamps do not use wood's glass. They use regular soda-lime glass and emit more visible light than BLB lamps.

Common tube ratings

This section lists the more common tube ratings for general lighting. Many more tube ratings exist, often country-specific. The Nominal Length may not exactly match any measured dimension of the tube. For some tube sizes, the nominal length (in feet) is the required spacing between centers of the lighting fixtures to create a continuous run, so the tubes are a little shorter than the nominal length.

class="wikitable"

! Tube diameter in {{convert|1/8|in|mm|3|abbr=on}} !! Nominal length !! Nominal power (W)

!Lamp Code

T5 Miniature

| {{cvt|6|in|mm|0}}

| 4

|F4T5

T5 Miniature

| {{cvt|9|in|mm|0}}

| 6

|F6T5

T5 Miniature

| {{cvt|12|in|mm|0}}

| 8

|F8T5

T5 Miniature

| {{cvt|21|in|mm|0}}

| 13

|F13T5

T5/HE

|{{Cvt|22|in|mm}}

|14

|F14T5

T5/HE

|{{Cvt|34|in|mm}}

|21

|F21T5

T5/HE

|{{Cvt|46|in|mm}}

|28

|F28T5

T5/HE

|{{Cvt|58|in|mm}}

|35

|F35T5

T5/HO

|{{Cvt|22|in|mm}}

|24

|F24T5/HO

T5/HO

|{{Cvt|34|in|mm}}

|39

|F39T5/HO

T5/HO

|{{Cvt|46|in|mm}}

|54

|F54T5/HO

T5/HO

|{{Cvt|58|in|mm}}

|80

|F80T5/HO

T8

| {{cvt|15|in|mm|0}}

| 14

|F14T8

T8

|{{Cvt|18|in|mm}}

|15

|F15T8

T8

| {{cvt|2|ft|mm|0}}

| 17

|F17T8

T8

|2 ft (610 mm)

|18

|N/A

T8

| {{cvt|3|ft|mm|0}}

| 25

|F25T8

T8

|3 ft (914 mm)

|30

|F30T8

abbr="on"

| T8

| {{cvt|4|ft|mm|0}}

| 32

|F32T8

T8

|4 ft (1,219 mm)

|36

|N/A

T8

| {{cvt|5|ft|mm|0}}

| 40

|F40T8

T8

|5 ft (1,524 mm)

|58

|N/A

T8

| {{cvt|6|ft|mm|0}}

| 70

|N/A

T8 single-pin

|{{cvt|6|ft|mm|0}}

|38

|F72T8

T8 single-pin

|8 ft (2,438 mm)

|51

|F96T8

T8 single-pin

|{{cvt|8|ft|mm|0}}

|59

|F96T8

T8/HO

|{{cvt|4|ft|mm|0}}

|44

|F48T8/HO

T8/HO

|{{cvt|5|ft|mm|0}}

|55

|F60T8/HO

T8/HO

|{{cvt|6|ft|mm|0}}

|65

|F72T8/HO

T8/HO

|{{cvt|8|ft|mm|0}}

|86

|F96T8/HO

T12

| {{cvt|15|in|mm|0|abbr=on}}

| 14

|F14T12

T12

| {{cvt|18|in|mm|0}}

| 15

|F15T12

T12

| {{cvt|2|ft|mm|0}}

| 20

|F20T12

T12

|{{cvt|3|ft|mm|0}}

|30

|F30T12

T12

| {{cvt|4|ft|mm|0}}

| 40

|F40T12

T12

| {{cvt|5|ft|mm|0}}

| 65

|N/A

T12

|5 ft (1,524 mm)

|80

|N/A

T12

| {{cvt|6|ft|mm|0}}

| 75

|N/A

T12

|6 ft (1,829 mm)

|85

|N/A

T12

| {{cvt|8|ft|mm|0}}

| 125

|N/A

T12 single-pin

|{{cvt|4|ft|mm|0}}

|39

|F48T12

T12 single-pin

|{{cvt|6|ft|mm|0}}

|55

|F72T12

T12 single-pin

|{{cvt|8|ft|mm|0}}

|75

|F96T12

T12/HO

|{{cvt|4|ft|mm|0}}

|60

|F48T12/HO

T12/HO

|{{cvt|5|ft|mm|0}}

|75

|F60T12/HO

T12/HO

|{{cvt|6|ft|mm|0}}

|85

|F72T12/HO

T12/HO

|{{cvt|8|ft|mm|0}}

|110

|F96T12/HO

T12/VHO

|{{cvt|4|ft|mm|0}}

|115

|F48T12/VHO

T12/VHO

|{{cvt|6|ft|mm|0}}

|160

|F72T12/VHO

T12/VHO

|{{cvt|8|ft|mm|0}}

|215

|F96T12/VHO

=European energy-saving tubes=

In the 1970s, Thorn Lighting introduced an energy-saving 8 ft retrofit tube in Europe. Designed to run on the existing 125 W (240 V) series ballast but with a different gas fill and operating voltage, the tube operated at only 100 W. Increased efficiency meant that the tube produced only 9% lumen reduction for a 20% power reduction.Thorn Lighting Technical Handbook This first energy-saving tube design remains a T12 tube even today. However, follow-on retrofit replacements for all the other original T12 tubes were T8, which helped with creating the required electrical characteristics and saving on the then new (and more expensive) polyphosphor/triphosphor coatings, and these were even more efficient. Note that because these tubes were all designed as retrofit tubes to be fitted in T12 fittings running on series ballasts on 220–240 V supplies, they could not be used in 120 V mains countries with inherently different control gear designs.

class="wikitable"

! Type !! Diameter (in, mm) !! Nominal length (ft, m) !! Nominal power (W) !! Notes

T81.0, 252, 0.618Retrofit replacement for 2 ft T12 20 W
T81.0, 254, 1.236Retrofit replacement for 4 ft T12 40 W
T81.0, 255, 1.558Retrofit replacement for 5 ft T12 65 W
T81.0, 256, 1.870Retrofit replacement for 6 ft T12 75 W
T121.5, 388, 2.4100Retrofit replacement for 8 ft T12 125 W

Around 1980 (in the UK, at least), some new fluorescent fittings were designed to take only the newer, retrofit tubes (the lamp holders are designed not to take T12 tubes, except for 8 ft length). The earlier T12 halophosphate tubes still remained available as spares until 2012. They fit in older fittings and some modern fittings that employ twist lock lamp holders, even though the modern fittings were not electrically designed for them.

=US energy-saving tubes=

In the 1970s, 34-watt energy-saving F40T12 fluorescent lamps were intoroduced in the United States. In the 1980s, T8 32-watt lamps were introduced,{{Cite web |title=4-Foot T-8 Fluorescent Lamp Upgrading |url=https://deq.nc.gov/media/1441/download |access-date=2 November 2022}} but unlike the T8 tubes introduced in Europe, these T8s are not retrofits and require new matching ballasts to drive them. These ballasts were originally magnetic, but most today are electronic. The energy-saving T12 lamps are made to operate on ballasts designed for 40-watt F40T12 lamps, though some F40T12 ballasts are not be designed to operate these lamps, and can overheat if energy-saving lamps are used. Running an energy-saving T8 tube with a ballast for T12 will reduce lamp life and can increase energy consumption.{{cite web|url=http://www.lightingdesignlab.com/commercial/articles/Energy_Code.htm|title=Energy Codes

|date=1995-11-01|archive-url=https://web.archive.org/web/20110522035143/http://www.lightingdesignlab.com/commercial/articles/Energy_Code.htm|archive-date=2011-05-22}} Conversely, a T12 tube on a T8 ballast will usually draw too much power and so may burn out the ballast, unless it is within the range that particular ballast can compensate for. The tube type should always match the markings on the light fixture.

class="wikitable"

! Type !! Diameter (in, mm) !! Nominal length (ft) !! Nominal power (W)

!Lamp Code!! Notes

T5

|0.625, 16

|4

|49

|F49T5

|Retrofit replacement for 45.8 in T5HO 54 W

T8

|1.0, 25

|4

|25

|F32T8/25w

|Retrofit replacement for 4 ft T8 32 W

T8

|1.0, 25

|4

|28

|F28T8

F32T8/28w

|Retrofit replacement for 4 ft T8 32 W

T8

|1.0, 25

|4

|30

|F32T8/ES

|Retrofit replacement for 4 ft T8 32 W

T81.0, 25217

|F17T8

Ballast-swap replacement for 2 ft T12 20 W
T8

|1.0, 25

|3

|25

|F25T8

|Ballast-swap replacement for 3 ft T12 30 W

T81.0, 25432

|F32T8

Ballast-swap replacement for 4 ft T12 40 W
T81.0, 25859

|F96T8

Ballast-swap replacement for 8 ft T12 75 W single-pin
T121.5, 384"25"

|F40UTSL

| Retrofit replacement for 4 ft T12 40 W on underpowered residential-grade rapid start magnetic ballasts. These are F40CW lamps made with

lighter cathodes that can only handle a lower amount of power. They will function as a standard 40 W lamp on full-power ballasts, but may not last as long. These lamps are typically rated to last for 12,000

hours on a residential-grade ballast and only 6000 hours

on a commercial-grade one.

T12

|1.5, 38

|4

|32

|F40T12/ESP

|Retrofit replacement for 4 ft T12 40 W

T12

|1.5, 38

|4

|34

|F34T12

F40T12/ES

|Retrofit replacement for 4 ft T12 40 W

T12

|1.5, 38

|8

|60

|F96T12/ES

|Retrofit replacement for 8 ft T12 75 W single-pin

T12

|1.5, 38

|8

|95

|F96T12/HO/ES

|Retrofit replacement for 8 ft T12 110 W high-output

T5 tubes

In the 1990s, longer T5 tubes were designed in Europe (making it to North America in the 2000s), in addition to the shorter ones (mentioned above) already in use worldwide. Like the European modular furniture, display cabinets, ceiling tile grids, etc. they were designed for, these are based on multiples of the {{convert|300|mm|in|1|abbr=on}} "metric foot" instead of the {{convert|12|in|mm|0|abbr=on}} imperial foot, but are all {{convert|37|mm|in|1|abbr=on}} shorter to allow space for the lampholder connections within the 300 mm modular units, and for much easier insertion into and removal from troffer lights within a grid.

class="wikitable"

! rowspan=2 | Tube diameter is {{Convert|5/8|in|mm|3|abbr=on}}

! rowspan=2 | Length

! colspan=2 | Nominal power (W)

! rowspan=2 | Notes

High-efficiency

! High-output

T5

| {{Convert|563|mm|in|abbr=on}}

| 14

| 24

| Fits within a 0.6 m modular unit

T5

| {{Convert|863|mm|in|abbr=on}}

| 21

| 39

| Fits within a 0.9 m modular unit

T5

| {{Convert|1163|mm|in|abbr=on}}

| 28

| 54

| Fits within a 1.2 m modular unit

T5

| {{Convert|1463|mm|in|abbr=on}}

| 35

| 80

| Fits within a 1.5 m modular unit

The T5 diameter is nearly 40% smaller than T8 lamps and almost 60% smaller than T12 lamps. T5 lamps have a G5 base (bi-pin with 5 mm spacing), even for high-output (HO and VHO) tubes.Lighting Research Center, "T5 Fluorescent Systems", [http://www.lrc.rpi.edu/programs/nlpip/lightingAnswers/lat5/abstract.asp], accessed 11-30-2009.

Electrical parameters of linear tubes

[https://www.voltimum.com.au/sites/www.voltimum.com.au/files/au/flipbooks/20121210-01_41_12/Fluorescent_Tubes.pdf]

class="wikitable"

|

|Power

|Lamp voltage

|Lamp current

rowspan="3" |T4

|7W

|32V

|0,195A

10W

|42V

|0,210A

18W

|65V

|0,228A

rowspan="4" |T5HE

|14W

|86V

|0,165A

21W

|126V

|0,165A

28W

|166V

|0,170A

35W

|205V

|0,175A

rowspan="5" |T5HO

|24W

|77V

|0,295A

39W

|118V

|0,325A

49W

|195V

|0,299A

54W

|120V

|0,455A

80W

|152V

|0,530A

rowspan="3" |T5

|6W

|42V

|0,160A

8W

|56V

|0,145A

13W

|95V

|0,165A

rowspan="9" |T8

|14W

|38V

|0,395A

15W

|55V

|0,310A

18W

|57V

|0,370A

25W

|84V

|0,360A

30W

|96V

|0,365A

32W

|135V

|0,265A

36W

|103V

|0,430A

58W

|110V

|0,670A

70W

|128V

|0,700A

rowspan="3" |T9C

|22W

|62V

|0,400A

32W

|84V

|0,450A

40W

|115V

|0,415A

rowspan="4" |T12

|20W

|57V

|0,370A

40W

|103V

|0,430A

75W

|130V

|0,670A

85W

|120V

|0,800A

rowspan="3" |T12 single pin

|52W

|136V

|0,425A

55W

|149V

|0,425A

75W

|197V

|0,425A

rowspan="8" |T12 HO

|60W

|79V

|0,800A

70W

|95V

|0,800A

85W

|116V

|0,800A

110W

|152V

|0,800A

115W

|83V

|1,500A

135W

|109V

|1,500A

160W

|124V

|1,500A

215W

|145V

|1,500A