Electroencephalography (EEG)

Compare EEC: {{cite book |url=https://books.google.com/books?id=8ceEAgAAQBAJ |title=Sport and Exercise Psychology: A Critical Introduction |vauthors=Moran A |date=2 August 2004 |publisher=Routledge |isbn=9781134704101 |publication-place=Hove, East Sussex |page=104 |quote=[...] electroencephalographic (EEC) methods [...]. In a typical EEC experiment, an electrode is attached to a person's scalp in order to detect the electrical activity of neurons in the underlying brain region. Another electrode is then attached to the person's earlobe, where there is no electrical activity to detect. Then the EEC is recorded to indicate the difference in electrical potentials detected by the electrodes [...]. In recent years, a considerable amount of research has been conducted on EEC activity in athletes [...]. |access-date=6 July 2024}}

is a method to record an electrogram of the spontaneous electrical activity of the brain. The bio signals detected by EEG have been shown to represent the postsynaptic potentials of pyramidal neurons in the neocortex and allocortex.{{Cite book | vauthors = Amzica F, Lopes da Silva FH |url=https://academic.oup.com/book/35515/chapter/305245903 |title= Cellular Substrates of Brain Rhythms |date=November 2017 |publisher=Oxford University Press | veditors = Schomer DL, Lopes da Silva FH |volume=1 |language=en |doi= 10.1093/med/9780190228484.003.0002 }} It is typically non-invasive, with the EEG electrodes placed along the scalp (commonly called "scalp EEG") using the International 10–20 system, or variations of it. Electrocorticography, involving surgical placement of electrodes, is sometimes called "intracranial EEG". Clinical interpretation of EEG recordings is most often performed by visual inspection of the tracing or quantitative EEG analysis.

Voltage fluctuations measured by the EEG bio amplifier and electrodes allow the evaluation of normal brain activity. As the electrical activity monitored by EEG originates in neurons in the underlying brain tissue, the recordings made by the electrodes on the surface of the scalp vary in accordance with their orientation and distance to the source of the activity. Furthermore, the value recorded is distorted by intermediary tissues and bones, which act in a manner akin to resistors and capacitors in an electrical circuit. This means that not all neurons will contribute equally to an EEG signal, with an EEG predominately reflecting the activity of cortical neurons near the electrodes on the scalp. Deep structures within the brain further away from the electrodes will not contribute directly to an EEG; these include the base of the cortical gyrus, mesial walls of the major lobes, hippocampus, thalamus, and brain stem.{{Cite book |url=https://www.worldcat.org/oclc/1199587061 |title=Principles of neural science |date=2021 |author1=Eric R. Kandel|author2=John Koester|author3=Sarah Mack|author4= Steven Siegelbaum |isbn=978-1-259-64223-4|publisher=McGraw-Hill Companies|edition=6th |location=New York |pages=1450 |oclc=1199587061}}

A healthy human EEG will show certain patterns of activity that correlate with how awake a person is. The range of frequencies one observes are between 1 and 30 Hz, and amplitudes will vary between 20 and 100 μV. The observed frequencies are subdivided into various groups: alpha (8–13 Hz), beta (13–30 Hz), delta (0.5–4 Hz), and theta (4–7 Hz). Alpha waves are observed when a person is in a state of relaxed wakefulness and are mostly prominent over the parietal and occipital sites. During intense mental activity, beta waves are more prominent in frontal areas as well as other regions. If a relaxed person is told to open their eyes, one observes alpha activity decreasing and an increase in beta activity. Theta and delta waves are not generally seen in wakefulness – if they are, it is a sign of brain dysfunction.

EEG can detect abnormal electrical discharges such as sharp waves, spikes, or spike-and-wave complexes, as observable in people with epilepsy; thus, it is often used to inform medical diagnosis. EEG can detect the onset and spatio-temporal (location and time) evolution of seizures and the presence of status epilepticus. It is also used to help diagnose sleep disorders, depth of anesthesia, coma, encephalopathies, cerebral hypoxia after cardiac arrest, and brain death. EEG used to be a first-line method of diagnosis for tumors, stroke, and other focal brain disorders,{{Cite web|url=https://medlineplus.gov/ency/article/003931.htm|title=EEG: MedlinePlus Medical Encyclopedia|website=medlineplus.gov|access-date=July 24, 2022|archive-date=July 5, 2016|archive-url=https://web.archive.org/web/20160705035021/https://www.nlm.nih.gov/medlineplus/ency/article/003931.htm|url-status=live}}{{cite book| vauthors = Chernecky CC, Berger BJ |title=Laboratory tests and diagnostic procedures|date=2013|publisher=Elsevier|location=St. Louis, Mo.|isbn=978-1-4557-0694-5|edition=6th}} but this use has decreased with the advent of high-resolution anatomical imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT). Despite its limited spatial resolution, EEG continues to be a valuable tool for research and diagnosis. It is one of the few mobile techniques available and offers millisecond-range temporal resolution, which is not possible with CT, PET, or MRI.{{cite journal | vauthors = Deschamps A, Ben Abdallah A, Jacobsohn E, Saha T, Djaiani G, El-Gabalawy R, Overbeek C, Palermo J, Courbe A, Cloutier I, Tanzola R, Kronzer A, Fritz BA, Schmitt EM, Inouye SK, Avidan MS | title = Electroencephalography-Guided Anesthesia and Delirium in Older Adults After Cardiac Surgery: The ENGAGES-Canada Randomized Clinical Trial | journal = JAMA | volume = 332 | issue = 2 | pages = 112–123 | date = July 2024 | pmid = 38857019 | pmc = 11165413 | doi = 10.1001/jama.2024.8144 }}{{cite journal | vauthors = Hao D, Fritz BA, Saddawi-Konefka D, Palanca BJ | title = Pro-Con Debate: Electroencephalography-Guided Anesthesia for Reducing Postoperative Delirium | journal = Anesthesia and Analgesia | volume = 137 | issue = 5 | pages = 976–982 | date = November 2023 | pmid = 37862399 | doi = 10.1213/ANE.0000000000006399 }}

Derivatives of the EEG technique include evoked potentials (EP), which involves averaging the EEG activity time-locked to the presentation of a stimulus of some sort (visual, somatosensory, or auditory). Event-related potentials (ERPs) refer to averaged EEG responses that are time-locked to more complex processing of stimuli; this technique is used in cognitive science, cognitive psychology, and psychophysiological research.

Uses

=Epilepsy=

File:EEG cap.jpg

EEG is the gold standard diagnostic procedure to confirm epilepsy. The sensitivity of a routine EEG to detect interictal epileptiform discharges at epilepsy centers has been reported to be in the range of 29–55%.{{cite journal | vauthors = Pillai J, Sperling MR | title = Interictal EEG and the diagnosis of epilepsy | journal = Epilepsia | volume = 47 Suppl 1 | issue = Suppl 1 | pages = 14–22 | date = 2006 | pmid = 17044820 | doi = 10.1111/j.1528-1167.2006.00654.x | url = https://pubmed.ncbi.nlm.nih.gov/17044820 | access-date = October 23, 2022 | url-status = live | s2cid = 8668713 | archive-url = https://web.archive.org/web/20221023033520/https://pubmed.ncbi.nlm.nih.gov/17044820/ | archive-date = October 23, 2022 }} Given the low to moderate sensitivity, a routine EEG (typically with a duration of 20–30 minutes) can be normal in people that have epilepsy. When an EEG shows interictal epileptiform discharges (e.g. sharp waves, spikes, spike-and-wave, etc.) it is confirmatory of epilepsy in nearly all cases (high specificity), however up to 3.5% of the general population may have epileptiform abnormalities in an EEG without ever having had a seizure (low false positive rate) or with a very low risk of developing epilepsy in the future.{{cite journal | vauthors = So EL | title = Interictal epileptiform discharges in persons without a history of seizures: what do they mean? | journal = Journal of Clinical Neurophysiology | volume = 27 | issue = 4 | pages = 229–238 | date = August 2010 | pmid = 20634716 | doi = 10.1097/WNP.0b013e3181ea42a4 }}

When a routine EEG is normal and there is a high suspicion or need to confirm epilepsy, it may be repeated or performed with a longer duration in the epilepsy monitoring unit (EMU) or at home with an ambulatory EEG. In addition, there are activating maneuvers such as photic stimulation, hyperventilation and sleep deprivation that can increase the diagnostic yield of the EEG.

= Epilepsy Monitoring Unit (EMU) =

At times, a routine EEG is not sufficient to establish the diagnosis or determine the best course of action in terms of treatment. In this case, attempts may be made to record an EEG while a seizure is occurring. This is known as an ictal recording, as opposed to an interictal recording, which refers to the EEG recording between seizures. To obtain an ictal recording, a prolonged EEG is typically performed accompanied by a time-synchronized video and audio recording. This can be done either as an outpatient (at home) or during a hospital admission, preferably to an Epilepsy Monitoring Unit (EMU) with nurses and other personnel trained in the care of patients with seizures. Outpatient ambulatory video EEGs typically last one to three days. An admission to an Epilepsy Monitoring Unit typically lasts several days but may last for a week or longer. While in the hospital, seizure medications are usually withdrawn to increase the odds that a seizure will occur during admission. For reasons of safety, medications are not withdrawn during an EEG outside of the hospital. Ambulatory video EEGs, therefore, have the advantage of convenience and are less expensive than a hospital admission, but they also have the disadvantage of a decreased probability of recording a clinical event.{{cite journal |vauthors=Li C, Amin U, Rivera-Cruz A, Frontera AT, Benbadis SR |date=October 2023 |title=The Yield of Ambulatory Video-EEG – Predictors of Successful Event Capture |journal=Neurology Clinical Practice |volume=13 |issue=5 |pages=e200194 |doi=10.1212/CPJ.0000000000200194 |pmc=10511269 |pmid=37736066}}

Epilepsy monitoring is often considered when patients continue having events despite being on anti-seizure medications or if there is concern that the patient's events have an alternate diagnosis, e.g., psychogenic non-epileptic seizures, syncope (fainting), sub-cortical movement disorders, migraine variants, stroke, etc. In cases of epileptic seizures, continuous EEG monitoring helps to characterize seizures and localize/lateralize the region of the brain from which a seizure originates. This can help identify appropriate non-medication treatment options.{{cite journal |vauthors=van Rooij LG, Hellström-Westas L, de Vries LS |date=August 2013 |title=Treatment of neonatal seizures |journal=Seminars in Fetal & Neonatal Medicine |volume=18 |issue=4 |pages=209–215 |doi=10.1016/j.siny.2013.01.001 |pmid=23402893}} In clinical use, EEG traces are visually analyzed by neurologists to look at various features. Increasingly, quantitative analysis of EEG is being used in conjunction with visual analysis. Quantitative analysis displays like power spectrum analysis, alpha-delta ratio, amplitude integrated EEG, and spike detection can help quickly identify segments of EEG that need close visual analysis or, in some cases, be used as surrogates for quick identification of seizures in long-term recordings.

= Other brain disorders =

An EEG might also be helpful for diagnosing or treating the following disorders:{{Cite web|url=https://www.mayoclinic.org/tests-procedures/eeg/about/pac-20393875|title=EEG (Electroencephalogram) – Mayo Clinic|website=Mayo Clinic|access-date=August 30, 2019|archive-date=August 30, 2019|archive-url=https://web.archive.org/web/20190830221430/https://www.mayoclinic.org/tests-procedures/eeg/about/pac-20393875|url-status=live}}

  • Brain tumor
  • Brain damage from head injury
  • Brain dysfunction that can have a variety of causes (encephalopathy)
  • Inflammation of the brain (encephalitis)
  • Stroke
  • Sleep disorders

It can also:

= Intensive Care Unit (ICU) =

EEG can also be used in intensive care units for brain function monitoring to monitor for non-convulsive seizures/non-convulsive status epilepticus, to monitor the effect of sedative/anesthesia in patients in medically induced coma (for treatment of refractory seizures or increased intracranial pressure), and to monitor for secondary brain damage in conditions such as subarachnoid hemorrhage (currently a research method).{{Cite journal |last1=Rubinos |first1=Clio |last2=Alkhachroum |first2=Ayham |last3=Der-Nigoghossian |first3=Caroline |last4=Claassen |first4=Jan |date=2020 |title=Electroencephalogram Monitoring in Critical Care |journal=Seminars in Neurology |volume=40 |issue=6 |pages=675–680 |doi=10.1055/s-0040-1719073 |issn=1098-9021 |pmc=7856834 |pmid=33176375}}

In cases where significant brain injury is suspected, e.g., after cardiac arrest, EEG can provide some prognostic information.{{Citation needed|date=November 2024}}

If a patient with epilepsy is being considered for resective surgery to treat epilepsy, it is often necessary to localize the focus (source) of the epileptic brain activity with a resolution greater than what is provided by scalp EEG. In these cases, neurosurgeons typically implant strips and grids of electrodes or penetrating depth electrodes under the dura mater, through either a craniotomy or a burr hole. The recording of these signals is referred to as electrocorticography (ECoG), subdural EEG (SDE), intracranial EEG (iEEG), or stereotactic EEG (SEEG). The signal recorded from ECoG is on a different scale of activity than the brain activity recorded from scalp EEG. Low-voltage, high-frequency components that cannot be seen easily (or at all) in scalp EEG can be seen clearly in ECoG. Further, smaller electrodes (which cover a smaller parcel of brain surface) allow for better spatial resolution to narrow down the areas critical for seizure onset and propagation. Some clinical sites record data from penetrating microelectrodes.{{cite book| vauthors = Niedermeyer E, da Silva FL | title = Electroencephalography: Basic Principles, Clinical Applications, and Related Fields | publisher = Lippincott Williams & Wilkins | year = 2004| isbn = 978-0-7817-5126-1}}{{page needed|date=August 2013}}

= Home ambulatory EEG =

Sometimes it is more convenient or clinically necessary to perform ambulatory EEG recordings in the home of the person being tested.{{Cite journal |last1=Lawley |first1=Andrew |last2=Evans |first2=Shaun |last3=Manfredonia |first3=Francesco |last4=Cavanna |first4=Andrea E. |date=2015 |title=The role of outpatient ambulatory electroencephalography in the diagnosis and management of adults with epilepsy or nonepileptic attack disorder: A systematic literature review |url=https://pubmed.ncbi.nlm.nih.gov/26515156 |journal=Epilepsy & Behavior |volume=53 |pages=26–30 |doi=10.1016/j.yebeh.2015.09.032 |issn=1525-5069 |pmid=26515156}}{{Cite book |last1=Seneviratne |first1=Udaya |last2=D'Souza |first2=Wendyl Jude |title=Clinical Neurophysiology: Basis and Technical Aspects |date=2019 |chapter=Ambulatory EEG |chapter-url=https://pubmed.ncbi.nlm.nih.gov/31277845 |series=Handbook of Clinical Neurology |volume=160 |pages=161–170 |doi=10.1016/B978-0-444-64032-1.00010-2 |issn=0072-9752 |pmid=31277845|isbn=978-0-444-64032-1 }} These studies typically have a duration of 24–72 hours.{{citation needed|date=July 2023}}

Research use

{{Primary sources|section|date=December 2022}}

EEG and the related study of ERPs are used extensively in neuroscience, cognitive science, cognitive psychology, neurolinguistics, and psychophysiological research, as well as to study human functions such as swallowing.{{cite book | vauthors = Yang H, Ang KK, Wang C, Phua KS, Guan C | chapter = Neural and cortical analysis of swallowing and detection of motor imagery of swallow for dysphagia rehabilitation—A review | title = Brain-Computer Interfaces: Lab Experiments to Real-World Applications | volume = 228 | pages = 185–219 | date = 2016 | pmid = 27590970 | doi = 10.1016/bs.pbr.2016.03.014 | isbn = 978-0-12-804216-8 | series = Progress in Brain Research }}{{cite journal | vauthors = Jestrović I, Coyle JL, Sejdić E | title = Decoding human swallowing via electroencephalography: a state-of-the-art review | journal = Journal of Neural Engineering | volume = 12 | issue = 5 | pages = 051001 | date = October 2015 | pmid = 26372528 | pmc = 4596245 | doi = 10.1088/1741-2560/12/5/051001 | bibcode = 2015JNEng..12e1001J }}{{cite journal | vauthors = Cuellar M, Harkrider AW, Jenson D, Thornton D, Bowers A, Saltuklaroglu T | title = Time-frequency analysis of the EEG mu rhythm as a measure of sensorimotor integration in the later stages of swallowing | journal = Clinical Neurophysiology | volume = 127 | issue = 7 | pages = 2625–2635 | date = July 2016 | pmid = 27291882 | doi = 10.1016/j.clinph.2016.04.027 | s2cid = 3746307 }} Any EEG techniques used in research are not sufficiently standardised for clinical use, and many ERP studies fail to report all of the necessary processing steps for data collection and reduction,{{cite journal | vauthors = Clayson PE, Carbine KA, Baldwin SA, Larson MJ | title = Methodological reporting behavior, sample sizes, and statistical power in studies of event-related potentials: Barriers to reproducibility and replicability | journal = Psychophysiology | volume = 56 | issue = 11 | pages = e13437 | date = November 2019 | pmid = 31322285 | doi = 10.1111/psyp.13437 | s2cid = 197665482 | url = https://psyarxiv.com/kgv9z/ | access-date = October 7, 2022 | archive-date = October 7, 2022 | archive-url = https://web.archive.org/web/20221007045735/https://psyarxiv.com/kgv9z/ | url-status = live }} limiting the reproducibility and replicability of many studies. Based on a 2024 systematic literature review and meta analysis commissioned by the Patient-Centered Outcomes Research Institute (PCORI), EEG scans cannot be used reliably to assist in making a clinical diagnosis of ADHD.{{Cite journal |title=ADHD Diagnosis and Treatment in Children and Adolescents |url=https://effectivehealthcare.ahrq.gov/products/attention-deficit-hyperactivity-disorder/research |access-date=2024-06-19 |website=effectivehealthcare.ahrq.gov |date=2024 |language=en |doi=10.23970/ahrqepccer267 |pmid=38657097 | vauthors = Peterson BS, Trampush J, Maglione M, Bolshakova M, Brown M, Rozelle M, Motala A, Yagyu S, Miles J, Pakdaman S, Gastelum M, Nguyen BT, Tokutomi E, Lee E, Belay JZ, Schaefer C, Coughlin B, Celosse K, Molakalapalli S, Shaw B, Sazmin T, Onyekwuluje AN, Tolentino D, Hempel S }} However, EEG continues to be used in research on mental disabilities, such as auditory processing disorder (APD), ADD, and ADHD. EEGs have also been studied for their utility in detecting neurophysiological changes in the brain after concussion,{{Cite journal |last1=Burma |first1=Joel S. |last2=Lapointe |first2=Andrew P. |last3=Wilson |first3=Megan |last4=Penner |first4=Linden C. |last5=Kennedy |first5=Courtney M. |last6=Newel |first6=Kailey T. |last7=Galea |first7=Olivia A. |last8=Miutz |first8=Lauren N. |last9=Dunn |first9=Jeff F. |last10=Smirl |first10=Jonathan D. |date=2024 |title=Adolescent Sport-Related Concussion and the Associated Neurophysiological Changes: A Systematic Review |url=https://pubmed.ncbi.nlm.nih.gov/38006666 |journal=Pediatric Neurology |volume=150 |pages=97–106 |doi=10.1016/j.pediatrneurol.2023.10.020 |issn=1873-5150 |pmid=38006666}} however, at this time there are no advanced imaging techniques that can be used clinically to diagnose or monitor recovery from concussion.{{Cite web |title=Living Guideline for Pediatric Concussion |url=https://pedsconcussion.com/ |access-date=2024-11-21 |website=Living Guideline for Pediatric Concussion Care |language=en-US}}{{Cite web |title=Home {{!}} Living Concussion Guidelines |url=https://concussionsontario.org/ |access-date=2024-11-21 |website=concussionsontario.org}}

=Advantages=

Several other methods to study brain function exist, including functional magnetic resonance imaging (fMRI), positron emission tomography (PET), magnetoencephalography (MEG), nuclear magnetic resonance spectroscopy (NMR or MRS), electrocorticography (ECoG), single-photon emission computed tomography (SPECT), near-infrared spectroscopy (NIRS), and event-related optical signal (EROS). Despite the relatively poor spatial sensitivity of EEG, the "one-dimensional signals from localised peripheral regions on the head make it attractive for its simplistic fidelity and has allowed high clinical and basic research throughput".{{cite journal | vauthors = Burns T, Rajan R | title = Combining complexity measures of EEG data: multiplying measures reveal previously hidden information | journal = F1000Research | volume = 4 | pages = 137 | year = 2015 | pmid = 26594331 | pmc = 4648221 | doi = 10.12688/f1000research.6590.1 | doi-access = free }} Thus, EEG possesses some advantages over some of those other techniques:

  • Hardware costs are significantly lower than those of most other techniques{{cite journal | vauthors = Vespa PM, Nenov V, Nuwer MR | title = Continuous EEG monitoring in the intensive care unit: early findings and clinical efficacy | journal = Journal of Clinical Neurophysiology | volume = 16 | issue = 1 | pages = 1–13 | date = January 1999 | pmid = 10082088 | doi = 10.1097/00004691-199901000-00001 }}
  • EEG prevents limited availability of technologists to provide immediate care in high traffic hospitals.{{cite journal | vauthors = Schultz TL | title = Technical tips: MRI compatible EEG electrodes: advantages, disadvantages, and financial feasibility in a clinical setting | journal = The Neurodiagnostic Journal | volume = 52 | issue = 1 | pages = 69–81 | date = March 2012 | pmid = 22558648 }}
  • EEG only requires a quiet room and briefcase-size equipment, whereas fMRI, SPECT, PET, MRS, or MEG require bulky and immobile equipment. For example, MEG requires equipment consisting of liquid helium-cooled detectors that can be used only in magnetically shielded rooms, altogether costing upwards of several million dollars;{{cite journal |vauthors=Hämäläinen M, Hari R, Ilmoniemi RJ, Knuutila J, Lounasmaa OV |title=Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain |volume=65 |year=1993 |pages=413–97 |journal=Reviews of Modern Physics |doi=10.1103/RevModPhys.65.413 |issue=2 |url=https://aaltodoc.aalto.fi/handle/123456789/18757 |bibcode=1993RvMP...65..413H |access-date=September 10, 2018 |archive-date=January 26, 2019 |archive-url=https://web.archive.org/web/20190126001114/https://aaltodoc.aalto.fi/handle/123456789/18757 |url-status=live }} and fMRI requires the use of a 1-ton magnet in, again, a shielded room.
  • EEG can readily have a high temporal resolution, (although sub-millisecond resolution generates less meaningful data), because the two to 32 data streams generated by that number of electrodes is easily stored and processed, whereas 3D spatial technologies provide thousands or millions times as many input data streams, and are thus limited by hardware and software.{{cite journal | vauthors = Montoya-Martínez J, Vanthornhout J, Bertrand A, Francart T |title=Effect of number and placement of EEG electrodes on measurement of neural tracking of speech |journal=PLOS ONE |date=2021 |volume=16 |issue=2 |pages=e0246769 |doi=10.1371/journal.pone.0246769 |doi-access=free |pmid=33571299 |pmc=7877609 |bibcode=2021PLoSO..1646769M | biorxiv = 10.1101/800979 }} EEG is commonly recorded at sampling rates between 250 and 2000 Hz in clinical and research settings.
  • EEG is relatively tolerant of subject movement, unlike most other neuroimaging techniques. There even exist methods for minimizing, and even eliminating movement artifacts in EEG data{{cite conference |doi=10.1109/IEMBS.2010.5627282 |title=Automatic detection of EEG artifacts arising from head movements |book-title=2010 Annual International Conference of the IEEE Engineering in Medicine and Biology |year=2010 | vauthors = O'Regan S, Faul S, Marnane W |isbn=978-1-4244-4123-5 |pages=6353–6}}
  • EEG is silent, which allows for better study of the responses to auditory stimuli.
  • EEG does not aggravate claustrophobia, unlike fMRI, PET, MRS, SPECT, and sometimes MEG{{cite journal | vauthors = Murphy KJ, Brunberg JA | title = Adult claustrophobia, anxiety and sedation in MRI | journal = Magnetic Resonance Imaging | volume = 15 | issue = 1 | pages = 51–54 | year = 1997 | pmid = 9084025 | doi = 10.1016/S0730-725X(96)00351-7 }}
  • EEG does not involve exposure to high-intensity (>1 Tesla) magnetic fields, as in some of the other techniques, especially MRI and MRS. These can cause a variety of undesirable issues with the data, and also prohibit use of these techniques with participants that have metal implants in their body, such as metal-containing pacemakers{{cite journal | vauthors = Schenck JF | title = The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds | journal = Medical Physics | volume = 23 | issue = 6 | pages = 815–850 | date = June 1996 | pmid = 8798169 | doi = 10.1118/1.597854 | bibcode = 1996MedPh..23..815S }}
  • EEG does not involve exposure to radioligands, unlike positron emission tomography.{{cite journal | vauthors = Yasuno F, Brown AK, Zoghbi SS, Krushinski JH, Chernet E, Tauscher J, Schaus JM, Phebus LA, Chesterfield AK, Felder CC, Gladding RL, Hong J, Halldin C, Pike VW, Innis RB | title = The PET radioligand [11C]MePPEP binds reversibly and with high specific signal to cannabinoid CB1 receptors in nonhuman primate brain | journal = Neuropsychopharmacology | volume = 33 | issue = 2 | pages = 259–269 | date = January 2008 | pmid = 17392732 | doi = 10.1038/sj.npp.1301402 | doi-access = free }}
  • ERP studies can be conducted with relatively simple paradigms, compared with IE block-design fMRI studies
  • Relatively non-invasive, in contrast to electrocorticography, which requires electrodes to be placed on the actual surface of the brain.

EEG also has some characteristics that compare favorably with behavioral testing:

  • EEG can detect covert processing (i.e., processing that does not require a response){{cite book | vauthors = Mulholland T |chapter=Objective EEG Methods for Studying Covert Shifts of Visual Attention |chapter-url=https://books.google.com/books?id=esv8GMVwHwEC&pg=PA109 |pages=109–51 |year=2012 | veditors = McGuigan FJ, Schoonover RA |title=The Psychophysiology of Thinking: Studies of Covert Processes |publisher=Elsevier |isbn=978-0-323-14700-2}}
  • EEG can be used in subjects who are incapable of making a motor response{{cite journal | vauthors = Hinterberger T, Kübler A, Kaiser J, Neumann N, Birbaumer N | title = A brain-computer interface (BCI) for the locked-in: comparison of different EEG classifications for the thought translation device | journal = Clinical Neurophysiology | volume = 114 | issue = 3 | pages = 416–425 | date = March 2003 | pmid = 12705422 | doi = 10.1016/S1388-2457(02)00411-X | s2cid = 11857440 }}
  • EEG is a method widely used in the study of sport performance, valued for its portability and lightweight design{{Cite journal | vauthors = Cheng MY, Wang KP, Hung CL, Tu YL, Huang CJ, Koester D, Schack T, Hung TM |date=September 2017 |title=Higher power of sensorimotor rhythm is associated with better performance in skilled air-pistol shooters |url=https://linkinghub.elsevier.com/retrieve/pii/S1469029216303193 |journal=Psychology of Sport and Exercise |language=en |volume=32 |pages=47–53 |doi=10.1016/j.psychsport.2017.05.007|s2cid=33780406 }}
  • Some ERP components can be detected even when the subject is not attending to the stimuli
  • Unlike other means of studying reaction time, ERPs can elucidate stages of processing (rather than just the result){{cite journal | vauthors = Sereno SC, Rayner K, Posner MI | title = Establishing a time-line of word recognition: evidence from eye movements and event-related potentials | journal = NeuroReport | volume = 9 | issue = 10 | pages = 2195–2200 | date = July 1998 | pmid = 9694199 | doi = 10.1097/00001756-199807130-00009 | s2cid = 19466604 }}
  • the simplicity of EEG readily provides for tracking of brain changes during different phases of life. EEG sleep analysis can indicate significant aspects of the timing of brain development, including evaluating adolescent brain maturation.{{cite journal | vauthors = Feinberg I, Campbell IG | title = Longitudinal sleep EEG trajectories indicate complex patterns of adolescent brain maturation | journal = American Journal of Physiology. Regulatory, Integrative and Comparative Physiology | volume = 304 | issue = 4 | pages = R296–R303 | date = February 2013 | pmid = 23193115 | pmc = 3567357 | doi = 10.1152/ajpregu.00422.2012 }}
  • {{lay source |template = cite press release|url= https://www.sciencedaily.com/releases/2013/03/130319102757.htm|title = Sleep study reveals how the adolescent brain makes the transition to mature thinking|date = March 19, 2013|website = ScienceDaily }}
  • In EEG there is a better understanding of what signal is measured as compared to other research techniques, e.g. the BOLD response in MRI.

=Disadvantages=

  • Low spatial resolution on the scalp. fMRI, for example, can directly display areas of the brain that are active, while EEG requires intense interpretation just to hypothesize what areas are activated by a particular response.{{cite journal | vauthors = Srinivasan R |year=1999 |title=Methods to Improve the Spatial Resolution of EEG |journal=International Journal |volume=1 |issue=1 |pages=102–11}}
  • Depending on the orientation and location of the dipole causing an EEG change, there may be a false localization due to the inverse problem.{{cite journal | vauthors = Grech R, Cassar T, Muscat J, Camilleri KP, Fabri SG, Zervakis M, Xanthopoulos P, Sakkalis V, Vanrumste B | title = Review on solving the inverse problem in EEG source analysis | journal = Journal of Neuroengineering and Rehabilitation | volume = 5 | issue = 1 | pages = 25 | date = November 2008 | pmid = 18990257 | pmc = 2605581 | doi = 10.1186/1743-0003-5-25 | doi-access = free }}
  • EEG poorly measures neural activity that occurs below the upper layers of the brain (the cortex).
  • Unlike PET and MRS, EEG cannot identify specific locations in the brain at which various neurotransmitters, drugs, etc. can be found.
  • Often takes a long time to connect a subject to EEG, as it requires precise placement of dozens of electrodes around the head and the use of various gels, saline solutions, and pastes to maintain good conductivity, and a cap is used to keep them in place. While the length of time differs dependent on the specific EEG device used, as a general rule it takes considerably less time to prepare a subject for MEG, fMRI, MRS, and SPECT.
  • Signal-to-noise ratio is poor, so sophisticated data analysis and relatively large numbers of subjects are needed to extract useful information from EEG.{{cite web |vauthors=Schlögl A, Slater M, Pfurtscheller G |year=2002 |title=Presence research and EEG |url=http://www-dept.cs.ucl.ac.uk/research/equator/papers/Documents2002/Mel_presence_2002.pdf |access-date=August 24, 2013 |archive-date=August 11, 2017 |archive-url=https://web.archive.org/web/20170811142535/http://www-dept.cs.ucl.ac.uk/research/equator/papers/Documents2002/Mel_presence_2002.pdf |url-status=live }}
  • EEGs are not currently very compatible with individuals who have coarser or textured hair. Even protective styles can pose issues during testing. Researchers are currently trying to build better options for patients and technicians alike{{cite book | doi=10.1109/EMBC44109.2020.9176067 | chapter=Novel Electrodes for Reliable EEG Recordings on Coarse and Curly Hair | title=2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) | date=2020 | pages=6151–6154 | pmid=33019375 | isbn=978-1-7281-1990-8 | vauthors = Etienne A, Laroia T, Weigle H, Afelin A, Kelly SK, Krishnan A, Grover P |biorxiv=10.1101/2020.02.26.965202 }} Furthermore, researchers are starting to implement more culturally-informed data collection practices to help reduce racial biases in EEG research.{{cite journal | vauthors = Adams EJ, Scott ME, Amarante M, Ramírez CA, Rowley SJ, Noble KG, Troller-Renfree SV | title = Fostering inclusion in EEG measures of pediatric brain activity | journal = npj Science of Learning | volume = 9 | issue = 1 | pages = 27 | date = April 2024 | pmid = 38565857 | pmc = 10987610 | doi = 10.1038/s41539-024-00240-y | bibcode = 2024npjSL...9...27A }}

=With other neuroimaging techniques=

Simultaneous EEG recordings and fMRI scans have been obtained successfully,{{cite journal |doi=10.1002/hbm.460030103 |title=Simultaneous Functional Magnetic Resonance Imaging and Electrophysiological Recording |year=1995 | vauthors = Huang-Hellinger FR, Breiter HC, McCormack G, Cohen MS, Kwong KK, Sutton JP, Savoy RL, Weisskoff RM, Davis TL, Baker JR, Belliveau JW |journal=Human Brain Mapping |volume=3 |pages=13–23 |s2cid=145788101 }}{{cite journal | vauthors = Goldman RI, Stern JM, Engel J, Cohen MS | title = Acquiring simultaneous EEG and functional MRI | journal = Clinical Neurophysiology | volume = 111 | issue = 11 | pages = 1974–1980 | date = November 2000 | pmid = 11068232 | doi = 10.1016/s1388-2457(00)00456-9 | s2cid = 11716369 }}{{cite journal | vauthors = Horovitz SG, Skudlarski P, Gore JC | title = Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP | journal = Magnetic Resonance Imaging | volume = 20 | issue = 4 | pages = 319–325 | date = May 2002 | pmid = 12165350 | doi = 10.1016/S0730-725X(02)00496-4 }}{{cite journal | vauthors = Laufs H, Kleinschmidt A, Beyerle A, Eger E, Salek-Haddadi A, Preibisch C, Krakow K | title = EEG-correlated fMRI of human alpha activity | journal = NeuroImage | volume = 19 | issue = 4 | pages = 1463–1476 | date = August 2003 | pmid = 12948703 | doi = 10.1016/S1053-8119(03)00286-6 | s2cid = 6272011 | citeseerx = 10.1.1.586.3056 }} though recording both at the same time effectively requires that several technical difficulties be overcome, such as the presence of ballistocardiographic artifact, MRI pulse artifact and the induction of electrical currents in EEG wires that move within the strong magnetic fields of the MRI. While challenging, these have been successfully overcome in a number of studies.{{cite patent

| country =US

| number =7286871

| status =patent

| title =Method and apparatus for reducing contamination of an electrical signal

| pubdate =2004-05-20

| pridate =2000-08-15

| inventor =Mark S. Cohen

}}

{{cite journal | vauthors = Difrancesco MW, Holland SK, Szaflarski JP | title = Simultaneous EEG/functional magnetic resonance imaging at 4 Tesla: correlates of brain activity to spontaneous alpha rhythm during relaxation | journal = Journal of Clinical Neurophysiology | volume = 25 | issue = 5 | pages = 255–264 | date = October 2008 | pmid = 18791470 | pmc = 2662486 | doi = 10.1097/WNP.0b013e3181879d56 }}

MRI's produce detailed images created by generating strong magnetic fields that may induce potentially harmful displacement force and torque. These fields produce potentially harmful radio frequency heating and create image artifacts rendering images useless. Due to these potential risks, only certain medical devices can be used in an MR environment.

Similarly, simultaneous recordings with MEG and EEG have also been conducted, which has several advantages over using either technique alone:

  • EEG requires accurate information about certain aspects of the skull that can only be estimated, such as skull radius, and conductivities of various skull locations. MEG does not have this issue, and a simultaneous analysis allows this to be corrected for.
  • MEG and EEG both detect activity below the surface of the cortex very poorly, and like EEG, the level of error increases with the depth below the surface of the cortex one attempts to examine. However, the errors are very different between the techniques, and combining them thus allows for correction of some of this noise.
  • MEG has access to virtually no sources of brain activity below a few centimetres under the cortex. EEG, on the other hand, can receive signals from greater depth, albeit with a high degree of noise. Combining the two makes it easier to determine what in the EEG signal comes from the surface (since MEG is very accurate in examining signals from the surface of the brain), and what comes from deeper in the brain, thus allowing for analysis of deeper brain signals than either EEG or MEG on its own.{{cite journal | vauthors = Huizenga HM, van Zuijen TL, Heslenfeld DJ, Molenaar PC | title = Simultaneous MEG and EEG source analysis | journal = Physics in Medicine and Biology | volume = 46 | issue = 7 | pages = 1737–1751 | date = July 2001 | pmid = 11474922 | doi = 10.1088/0031-9155/46/7/301 | s2cid = 250761006 | citeseerx = 10.1.1.4.8384 | bibcode = 2001PMB....46.1737H }}

Recently, a combined EEG/MEG (EMEG) approach has been investigated for the purpose of source reconstruction in epilepsy diagnosis.{{cite journal | vauthors = Aydin Ü, Vorwerk J, Dümpelmann M, Küpper P, Kugel H, Heers M, Wellmer J, Kellinghaus C, Haueisen J, Rampp S, Stefan H, Wolters CH | title = Combined EEG/MEG can outperform single modality EEG or MEG source reconstruction in presurgical epilepsy diagnosis | journal = PLOS ONE | volume = 10 | issue = 3 | pages = e0118753 | year = 2015 | pmid = 25761059 | pmc = 4356563 | doi = 10.1371/journal.pone.0118753 | type = Review | doi-access = free | bibcode = 2015PLoSO..1018753A }}

EEG has also been combined with positron emission tomography. This provides the advantage of allowing researchers to see what EEG signals are associated with different drug actions in the brain.{{cite journal | vauthors = Schreckenberger M, Lange-Asschenfeldt C, Lange-Asschenfeld C, Lochmann M, Mann K, Siessmeier T, Buchholz HG, Bartenstein P, Gründer G | title = The thalamus as the generator and modulator of EEG alpha rhythm: a combined PET/EEG study with lorazepam challenge in humans | journal = NeuroImage | volume = 22 | issue = 2 | pages = 637–644 | date = June 2004 | pmid = 15193592 | doi = 10.1016/j.neuroimage.2004.01.047 | s2cid = 31790623 }}

Recent studies using machine learning techniques such as neural networks with statistical temporal features extracted from frontal lobe EEG brainwave data has shown high levels of success in classifying mental states (Relaxed, Neutral, Concentrating),{{cite book| vauthors = Bird J, Manso LJ, Ekart A, Faria DR |url=https://www.researchgate.net/publication/328615252|title=A Study on Mental State Classification using EEG-based Brain-Machine Interface|date=September 2018|publisher=9th international Conference on Intelligent Systems 2018|location=Madeira Island, Portugal|ref=birdeegmentalstates|access-date=December 3, 2018}} mental emotional states (Negative, Neutral, Positive){{cite book|vauthors=Bird JJ, Ekart A, Buckingham CD, Faria DR|url=https://www.disp-conference.org/|title=Mental Emotional Sentiment Classification with an EEG-based Brain-Machine Interface|date=2019|publisher=The International Conference on Digital Image and Signal Processing (DISP'19)|location=St Hugh's College, University of Oxford, United Kingdom|ref=birdeegemotions|access-date=December 3, 2018|archive-date=December 3, 2018|archive-url=https://web.archive.org/web/20181203202733/https://www.disp-conference.org/|url-status=live}} and thalamocortical dysrhythmia.{{cite journal | vauthors = Vanneste S, Song JJ, De Ridder D | title = Thalamocortical dysrhythmia detected by machine learning | language = En | journal = Nature Communications | volume = 9 | issue = 1 | pages = 1103 | date = March 2018 | pmid = 29549239 | pmc = 5856824 | doi = 10.1038/s41467-018-02820-0 | bibcode = 2018NatCo...9.1103V }}

Mechanisms

The brain's electrical charge is maintained by billions of neurons.{{cite journal | vauthors = Herculano-Houzel S | title = The human brain in numbers: a linearly scaled-up primate brain | journal = Frontiers in Human Neuroscience | volume = 3 | pages = 31 | year = 2009 | pmid = 19915731 | pmc = 2776484 | doi = 10.3389/neuro.09.031.2009 | doi-access = free }} Neurons are electrically charged (or "polarized") by membrane transport proteins that pump ions across their membranes. Neurons are constantly exchanging ions with the extracellular milieu, for example to maintain resting potential and to propagate action potentials. Ions of similar charge repel each other, and when many ions are pushed out of many neurons at the same time, they can push their neighbours, who push their neighbours, and so on, in a wave. This process is known as volume conduction. When the wave of ions reaches the electrodes on the scalp, they can push or pull electrons on the metal in the electrodes. Since metal conducts the push and pull of electrons easily, the difference in push or pull voltages between any two electrodes can be measured by a voltmeter. Recording these voltages over time gives us the EEG.{{cite book | vauthors = Tatum WO, Husain AM, Benbadis SR | date = 2008 | title = Handbook of EEG Interpretation | publisher = Demos Medical Publishing }}{{page needed|date=August 2013}}

The electric potential generated by an individual neuron is far too small to be picked up by EEG or MEG.{{cite book|vauthors=Nunez PL, Srinivasan R | title = Electric fields of the brain: The neurophysics of EEG |publisher = Oxford University Press | year = 1981 | isbn = 978-0-19-502796-9 | url = https://books.google.com/books?id=gu5qAAAAMAAJ}}{{page needed|date=August 2013}} EEG activity therefore always reflects the summation of the synchronous activity of thousands or millions of neurons that have similar spatial orientation. If the cells do not have similar spatial orientation, their ions do not line up and create waves to be detected. Pyramidal neurons of the cortex are thought to produce the most EEG signal because they are well-aligned and fire together. Because voltage field gradients fall off with the square of distance, activity from deep sources is more difficult to detect than currents near the skull.{{cite book | vauthors = Klein S, Thorne BM |date= October 3, 2006 |title=Biological psychology |location= New York, N.Y. |publisher= Worth |isbn=978-0-7167-9922-1 }}{{page needed|date=August 2013}}

Scalp EEG activity shows oscillations at a variety of frequencies. Several of these oscillations have characteristic frequency ranges, spatial distributions and are associated with different states of brain functioning (e.g., waking and the various sleep stages). These oscillations represent synchronized activity over a network of neurons. The neuronal networks underlying some of these oscillations are understood (e.g., the thalamocortical resonance underlying sleep spindles), while many others are not (e.g., the system that generates the posterior basic rhythm). Research that measures both EEG and neuron spiking finds the relationship between the two is complex, with a combination of EEG power in the gamma band and phase in the delta band relating most strongly to neuron spike activity.{{cite journal | vauthors = Whittingstall K, Logothetis NK | title = Frequency-band coupling in surface EEG reflects spiking activity in monkey visual cortex | journal = Neuron | volume = 64 | issue = 2 | pages = 281–289 | date = October 2009 | pmid = 19874794 | doi = 10.1016/j.neuron.2009.08.016 | s2cid = 17650488 | doi-access = free }}

Method

File:Electroencephalograph Neurovisor-BMM 40 (close view).jpg{{Primary sources|section|date=December 2022}}

In conventional scalp EEG, the recording is obtained by placing electrodes on the scalp with a conductive gel or paste, usually after preparing the scalp area by light abrasion to reduce impedance due to dead skin cells. Many systems typically use electrodes, each of which is attached to an individual wire. Some systems use caps or nets into which electrodes are embedded; this is particularly common when high-density arrays of electrodes are needed.{{citation needed|date=June 2022}}

Electrode locations and names are specified by the International 10–20 system{{cite journal | vauthors = Towle VL, Bolaños J, Suarez D, Tan K, Grzeszczuk R, Levin DN, Cakmur R, Frank SA, Spire JP | title = The spatial location of EEG electrodes: locating the best-fitting sphere relative to cortical anatomy | journal = Electroencephalography and Clinical Neurophysiology | volume = 86 | issue = 1 | pages = 1–6 | date = January 1993 | pmid = 7678386 | doi = 10.1016/0013-4694(93)90061-Y }} for most clinical and research applications (except when high-density arrays are used). This system ensures that the naming of electrodes is consistent across laboratories. In most clinical applications, 19 recording electrodes (plus ground and system reference) are used.{{cite journal | vauthors = | title = Guideline seven: a proposal for standard montages to be used in clinical EEG. American Electroencephalographic Society | journal = Journal of Clinical Neurophysiology | volume = 11 | issue = 1 | pages = 30–36 | date = January 1994 | pmid = 8195424 | doi = 10.1097/00004691-199401000-00008 }} A smaller number of electrodes are typically used when recording EEG from neonates. Additional electrodes can be added to the standard set-up when a clinical or research application demands increased spatial resolution for a particular area of the brain. High-density arrays (typically via cap or net) can contain up to 256 electrodes more-or-less evenly spaced around the scalp.

Each electrode is connected to one input of a differential amplifier (one amplifier per pair of electrodes); a common system reference electrode is connected to the other input of each differential amplifier. These amplifiers amplify the voltage between the active electrode and the reference (typically 1,000–100,000 times, or 60–100 dB of power gain). In analog EEG, the signal is then filtered (next paragraph), and the EEG signal is output as the deflection of pens as paper passes underneath. Most EEG systems these days, however, are digital, and the amplified signal is digitized via an analog-to-digital converter, after being passed through an anti-aliasing filter. Analog-to-digital sampling typically occurs at 256–512 Hz in clinical scalp EEG; sampling rates of up to 20 kHz are used in some research applications.

During the recording, a series of activation procedures may be used. These procedures may induce normal or abnormal EEG activity that might not otherwise be seen. These procedures include hyperventilation, photic stimulation (with a strobe light), eye closure, mental activity, sleep and sleep deprivation. During (inpatient) epilepsy monitoring, a patient's typical seizure medications may be withdrawn.

The digital EEG signal is stored electronically and can be filtered for display. Typical settings for the high-pass filter and a low-pass filter are 0.5–1 Hz and 35–70 Hz respectively. The high-pass filter typically filters out slow artifact, such as electrogalvanic signals and movement artifact, whereas the low-pass filter filters out high-frequency artifacts, such as electromyographic signals. An additional notch filter is typically used to remove artifact caused by electrical power lines (60 Hz in the United States and 50 Hz in many other countries).

The EEG signals can be captured with opensource hardware such as OpenBCI and the signal can be processed by freely available EEG software such as EEGLAB or the Neurophysiological Biomarker Toolbox.

As part of an evaluation for epilepsy surgery, it may be necessary to insert electrodes near the surface of the brain, under the surface of the dura mater. This is accomplished via burr hole or craniotomy. This is referred to variously as "electrocorticography (ECoG)", "intracranial EEG (I-EEG)" or "subdural EEG (SD-EEG)". Depth electrodes may also be placed into brain structures, such as the amygdala or hippocampus, structures, which are common epileptic foci and may not be "seen" clearly by scalp EEG. The electrocorticographic signal is processed in the same manner as digital scalp EEG (above), with a couple of caveats. ECoG is typically recorded at higher sampling rates than scalp EEG because of the requirements of Nyquist theorem – the subdural signal is composed of a higher predominance of higher frequency components. Also, many of the artifacts that affect scalp EEG do not impact ECoG, and therefore display filtering is often not needed.

A typical adult human EEG signal is about 10 μV to 100 μV in amplitude when measured from the scalp.{{cite journal | vauthors = Aurlien H, Gjerde IO, Aarseth JH, Eldøen G, Karlsen B, Skeidsvoll H, Gilhus NE | title = EEG background activity described by a large computerized database | journal = Clinical Neurophysiology | volume = 115 | issue = 3 | pages = 665–673 | date = March 2004 | pmid = 15036063 | doi = 10.1016/j.clinph.2003.10.019 | s2cid = 25988980 }}

Since an EEG voltage signal represents a difference between the voltages at two electrodes, the display of the EEG for the reading electroencephalographer may be set up in one of several ways. The representation of the EEG channels is referred to as a montage.

; Sequential montage: Each channel (i.e., waveform) represents the difference between two adjacent electrodes. The entire montage consists of a series of these channels. For example, the channel "Fp1-F3" represents the difference in voltage between the Fp1 electrode and the F3 electrode. The next channel in the montage, "F3-C3", represents the voltage difference between F3 and C3, and so on through the entire array of electrodes.

; Referential montage: Each channel represents the difference between a certain electrode and a designated reference electrode. There is no standard position for this reference; it is, however, at a different position than the "recording" electrodes. Midline positions are often used because they do not amplify the signal in one hemisphere vs. the other, such as Cz, Oz, Pz etc. as online reference. The other popular offline references are:

  • REST reference: which is an offline computational reference at infinity where the potential is zero. REST (reference electrode standardization technique) takes the equivalent sources inside the brain of any a set of scalp recordings as springboard to link the actual recordings with any an online or offline( average, linked ears etc.) non-zero reference to the new recordings with infinity zero as the standardized reference.{{cite journal | vauthors = Yao D | title = A method to standardize a reference of scalp EEG recordings to a point at infinity | journal = Physiological Measurement | volume = 22 | issue = 4 | pages = 693–711 | date = November 2001 | pmid = 11761077 | doi = 10.1088/0967-3334/22/4/305 | s2cid = 250847914 }}
  • "linked ears": which is a physical or mathematical average of electrodes attached to both earlobes or mastoids.

; Average reference montage: The outputs of all of the amplifiers are summed and averaged, and this averaged signal is used as the common reference for each channel.

; Laplacian montage: Each channel represents the difference between an electrode and a weighted average of the surrounding electrodes.{{cite journal | vauthors = Nunez PL, Pilgreen KL | title = The spline-Laplacian in clinical neurophysiology: a method to improve EEG spatial resolution | journal = Journal of Clinical Neurophysiology | volume = 8 | issue = 4 | pages = 397–413 | date = October 1991 | pmid = 1761706 | doi = 10.1097/00004691-199110000-00005 | s2cid = 38459560 }}

When analog (paper) EEGs are used, the technologist switches between montages during the recording in order to highlight or better characterize certain features of the EEG. With digital EEG, all signals are typically digitized and stored in a particular (usually referential) montage; since any montage can be constructed mathematically from any other, the EEG can be viewed by the electroencephalographer in any display montage that is desired.

The EEG is read by a clinical neurophysiologist or neurologist (depending on local custom and law regarding medical specialities), optimally one who has specific training in the interpretation of EEGs for clinical purposes. This is done by visual inspection of the waveforms, called graphoelements. The use of computer signal processing of the EEG – so-called quantitative electroencephalography – is somewhat controversial when used for clinical purposes (although there are many research uses).

= Dry EEG electrodes =

In the early 1990s Babak Taheri, at University of California, Davis demonstrated the first single and also multichannel dry active electrode arrays using micro-machining. The single channel dry EEG electrode construction and results were published in 1994.{{cite journal | vauthors = Taheri BA, Knight RT, Smith RL | title = A dry electrode for EEG recording | journal = Electroencephalography and Clinical Neurophysiology | volume = 90 | issue = 5 | pages = 376–383 | date = May 1994 | pmid = 7514984 | doi = 10.1016/0013-4694(94)90053-1 | url = https://zenodo.org/record/1253862 | access-date = December 10, 2019 | archive-date = December 22, 2019 | archive-url = https://web.archive.org/web/20191222051700/https://zenodo.org/record/1253862 | url-status = live }} The arrayed electrode was also demonstrated to perform well compared to silver/silver chloride electrodes. The device consisted of four sites of sensors with integrated electronics to reduce noise by impedance matching. The advantages of such electrodes are: (1) no electrolyte used, (2) no skin preparation, (3) significantly reduced sensor size, and (4) compatibility with EEG monitoring systems. The active electrode array is an integrated system made of an array of capacitive sensors with local integrated circuitry housed in a package with batteries to power the circuitry. This level of integration was required to achieve the functional performance obtained by the electrode. The electrode was tested on an electrical test bench and on human subjects in four modalities of EEG activity, namely: (1) spontaneous EEG, (2) sensory event-related potentials, (3) brain stem potentials, and (4) cognitive event-related potentials. The performance of the dry electrode compared favorably with that of the standard wet electrodes in terms of skin preparation, no gel requirements (dry), and higher signal-to-noise ratio.{{cite thesis| vauthors = Alizadeh-Taheri B |year=1994|title=Active Micromachined Scalp Electrode Array for Eeg Signal Recording|type=PhD thesis|publisher=University of California, Davis|page=82|bibcode=1994PhDT........82A}}

In 1999 researchers at Case Western Reserve University, in Cleveland, Ohio, led by Hunter Peckham, used 64-electrode EEG skullcap to return limited hand movements to quadriplegic Jim Jatich. As Jatich concentrated on simple but opposite concepts like up and down, his beta-rhythm EEG output was analysed using software to identify patterns in the noise. A basic pattern was identified and used to control a switch: Above average activity was set to on, below average off. As well as enabling Jatich to control a computer cursor the signals were also used to drive the nerve controllers embedded in his hands, restoring some movement.{{Cite magazine | vauthors = Hockenberry J |date=August 2001 |title=The Next Brainiacs |url=https://www.wired.com/wired/archive/9.08/assist_pr.html |magazine=Wired Magazine}}

In 2018, a functional dry electrode composed of a polydimethylsiloxane elastomer filled with conductive carbon nanofibers was reported. This research was conducted at the U.S. Army Research Laboratory.{{cite journal | vauthors = Slipher GA, Hairston WD, Bradford JC, Bain ED, Mrozek RA | title = Carbon nanofiber-filled conductive silicone elastomers as soft, dry bioelectronic interfaces | journal = PLOS ONE | volume = 13 | issue = 2 | pages = e0189415 | year = 2018 | pmid = 29408942 | pmc = 5800568 | doi = 10.1371/journal.pone.0189415 | doi-access = free | bibcode = 2018PLoSO..1389415S }} EEG technology often involves applying a gel to the scalp which facilitates strong signal-to-noise ratio. This results in more reproducible and reliable experimental results. Since patients dislike having their hair filled with gel, and the lengthy setup requires trained staff on hand, utilizing EEG outside the laboratory setting can be difficult.{{cite journal | vauthors = Wang F, Li G, Chen J, Duan Y, Zhang D | title = Novel semi-dry electrodes for brain-computer interface applications | journal = Journal of Neural Engineering | volume = 13 | issue = 4 | pages = 046021 | date = August 2016 | pmid = 27378253 | doi = 10.1088/1741-2560/13/4/046021 | s2cid = 26744679 | bibcode = 2016JNEng..13d6021W }} Additionally, it has been observed that wet electrode sensors' performance reduces after a span of hours. Therefore, research has been directed to developing dry and semi-dry EEG bioelectronic interfaces.{{citation needed|date=June 2022}}

Dry electrode signals depend upon mechanical contact. Therefore, it can be difficult getting a usable signal because of impedance between the skin and the electrode. Some EEG systems attempt to circumvent this issue by applying a saline solution.{{Cite journal|date=January 1, 2015|title=Multichannel EEG with novel Ti/TiN dry electrodes|journal=Sensors and Actuators A: Physical|language=en|volume=221|pages=139–147|doi=10.1016/j.sna.2014.10.010|issn=0924-4247| vauthors = Fiedler P, Griebel S, Pedrosa P, Fonseca C, Vaz F, Zentner L, Zanow F, Haueisen J |doi-access=free|bibcode=2015SeAcA.221..139F }} Others have a semi dry nature and release small amounts of the gel upon contact with the scalp. Another solution uses spring loaded pin setups. These may be uncomfortable. They may also be dangerous if they were used in a situation where a patient could bump their head since they could become lodged after an impact trauma incident.

Currently, headsets are available incorporating dry electrodes with up to 30 channels.{{Cite web|url=https://www.cgxsystems.com/products|title=Dry EEG Headsets | Products | CGX|website=CGX 2021|access-date=February 13, 2020|archive-date=February 13, 2020|archive-url=https://web.archive.org/web/20200213022928/https://www.cgxsystems.com/products|url-status=live}} Such designs are able to compensate for some of the signal quality degradation related to high impedances by optimizing pre-amplification, shielding and supporting mechanics.{{cite web |title=Dry EEG Technology |url=https://www.cgxsystems.com/technology |publisher=CGX LLC |access-date=February 13, 2020 |archive-date=February 13, 2020 |archive-url=https://web.archive.org/web/20200213022929/https://www.cgxsystems.com/technology |url-status=live }}

=Limitations=

EEG has several limitations. Most important is its poor spatial resolution.{{cite journal | vauthors = Kondylis ED, Wozny TA, Lipski WJ, Popescu A, DeStefino VJ, Esmaeili B, Raghu VK, Bagic A, Richardson RM | title = Detection of high-frequency oscillations by hybrid depth electrodes in standard clinical intracranial EEG recordings | journal = Frontiers in Neurology | volume = 5 | pages = 149 | date = 2014 | pmid = 25147541 | pmc = 4123606 | doi = 10.3389/fneur.2014.00149 | doi-access = free }} EEG is most sensitive to a particular set of post-synaptic potentials: those generated in superficial layers of the cortex, on the crests of gyri directly abutting the skull and radial to the skull. Dendrites which are deeper in the cortex, inside sulci, in midline or deep structures (such as the cingulate gyrus or hippocampus), or producing currents that are tangential to the skull, make far less contribution to the EEG signal.

EEG recordings do not directly capture axonal action potentials. An action potential can be accurately represented as a current quadrupole, meaning that the resulting field decreases more rapidly than the ones produced by the current dipole of post-synaptic potentials. In addition, since EEGs represent averages of thousands of neurons, a large population of cells in synchronous activity is necessary to cause a significant deflection on the recordings. Action potentials are very fast and, as a consequence, the chances of field summation are slim. However, neural backpropagation, as a typically longer dendritic current dipole, can be picked up by EEG electrodes and is a reliable indication of the occurrence of neural output.

Not only do EEGs capture dendritic currents almost exclusively as opposed to axonal currents, they also show a preference for activity on populations of parallel dendrites and transmitting current in the same direction at the same time. Pyramidal neurons of cortical layers II/III and V extend apical dendrites to layer I. Currents moving up or down these processes underlie most of the signals produced by electroencephalography.{{cite journal | vauthors = Murakami S, Okada Y | title = Contributions of principal neocortical neurons to magnetoencephalography and electroencephalography signals | journal = The Journal of Physiology | volume = 575 | issue = Pt 3 | pages = 925–936 | date = September 2006 | pmid = 16613883 | pmc = 1995687 | doi = 10.1113/jphysiol.2006.105379 }}

EEG thus provides information with a large bias in favor of particular neuron types, locations and orientations. So it generally should not be used to make claims about global brain activity. The meninges, cerebrospinal fluid and skull "smear" the EEG signal, obscuring its intracranial source.

It is mathematically impossible to reconstruct a unique intracranial current source for a given EEG signal, as some currents produce potentials that cancel each other out. This is referred to as the inverse problem. However, much work has been done to produce remarkably good estimates of, at least, a localized electric dipole that represents the recorded currents.{{Citation |last=Clerc |first=Maureen |title=Uniqueness result for an inverse conductivity recovery problem with application to EEG |date=2016 |url=http://www.openstarts.units.it/dspace/handle/10077/13165 |access-date=2025-06-03 |others=Università Degli Studi Di Trieste |publisher=EUT Edizioni Università di Trieste |doi=10.13137/2464-8728/13165 |last2=Leblond |first2=Juliette |last3=Marmorat |first3=Jean-Paul |last4=Papageorgakis |first4=Christos}}

=EEG vis-à-vis fMRI, fNIRS, fUS and PET=

EEG has several strong points as a tool for exploring brain activity. EEGs can detect changes over milliseconds, which is excellent considering an action potential takes approximately 0.5–130 milliseconds to propagate across a single neuron, depending on the type of neuron.{{cite book | vauthors = Anderson J |title= Cognitive Psychology and Its Implications |edition= 6th |publisher= Worth |location=New York, NY |page= 17 |isbn=978-0-7167-0110-1 | date=October 22, 2004 |type=Hardcover}} Other methods of looking at brain activity, such as PET, fMRI or fUS have time resolution between seconds and minutes. EEG measures the brain's electrical activity directly, while other methods record changes in blood flow (e.g., SPECT, fMRI, fUS) or metabolic activity (e.g., PET, NIRS), which are indirect markers of brain electrical activity.

EEG can be used simultaneously with fMRI or fUS so that high-temporal-resolution data can be recorded at the same time as high-spatial-resolution data, however, since the data derived from each occurs over a different time course, the data sets do not necessarily represent exactly the same brain activity.

There are technical difficulties associated with combining EEG and fMRI including the need to remove the MRI gradient artifact present during MRI acquisition. Furthermore, currents can be induced in moving EEG electrode wires due to the magnetic field of the MRI.

EEG can be used simultaneously with NIRS or fUS without major technical difficulties. There is no influence of these modalities on each other and a combined measurement can give useful information about electrical activity as well as hemodynamics at medium spatial resolution.

=EEG vis-à-vis MEG=

EEG reflects correlated synaptic activity caused by post-synaptic potentials of cortical neurons. The ionic currents involved in the generation of fast action potentials may not contribute greatly to the averaged field potentials representing the EEG.{{cite journal | vauthors = Creutzfeldt OD, Watanabe S, Lux HD | title = Relations between EEG phenomena and potentials of single cortical cells. I. Evoked responses after thalamic and erpicortical stimulation | journal = Electroencephalography and Clinical Neurophysiology | volume = 20 | issue = 1 | pages = 1–18 | date = January 1966 | pmid = 4161317 | doi = 10.1016/0013-4694(66)90136-2 }} More specifically, the scalp electrical potentials that produce EEG are generally thought to be caused by the extracellular ionic currents caused by dendritic electrical activity, whereas the fields producing magnetoencephalographic signals are associated with intracellular ionic currents.{{cite book| vauthors = Buzsaki G | title = Rhythms of the brain |publisher = Oxford University Press | year = 2006| isbn = 978-0-19-530106-9}}{{page needed|date=August 2013}}

Normal activity

File:Human EEG with prominent alpha-rhythm.png|Human EEG with prominent resting state activity – alpha-rhythm. Left: EEG traces (horizontal – time in seconds; vertical – amplitudes, scale 100 μV). Right: power spectra of shown signals (vertical lines – 10 and 20 Hz, scale is linear). Alpha-rhythm consists of sinusoidal-like waves with frequencies in 8–12 Hz range (11 Hz in this case) more prominent in posterior sites. Alpha range is red at power spectrum graph.

File:Human EEG without alpha-rhythm.png|Human EEG with in resting state. Left: EEG traces (horizontal – time in seconds; vertical – amplitudes, scale 100 μV). Right: power spectra of shown signals (vertical lines – 10 and 20 Hz, scale is linear). 80–90% of people have prominent sinusoidal-like waves with frequencies in 8–12 Hz range – alpha rhythm. Others (like this) lack this type of activity.

File:Human EEG artefacts.png |Common artifacts in human EEG. 1: Electrooculographic artifact caused by the excitation of eyeball's muscles (related to blinking, for example). Big-amplitude, slow, positive wave prominent in frontal electrodes. 2: Electrode's artifact caused by bad contact (and thus bigger impedance) between P3 electrode and skin. 3: Swallowing artifact. 4: Common reference electrode's artifact caused by bad contact between reference electrode and skin. Huge wave similar in all channels.

File:eeg raw.svg|One second of EEG signal

The EEG is typically described in terms of (1) rhythmic activity and (2) transients. The rhythmic activity is divided into bands by frequency. To some degree, these frequency bands are a matter of nomenclature (i.e., any rhythmic activity between 8–12 Hz can be described as "alpha"), but these designations arose because rhythmic activity within a certain frequency range was noted to have a certain distribution over the scalp or a certain biological significance. Frequency bands are usually extracted using spectral methods (for instance Welch) as implemented for instance in freely available EEG software such as EEGLAB or the Neurophysiological Biomarker Toolbox.

Computational processing of the EEG is often named quantitative electroencephalography (qEEG).

Most of the cerebral signal observed in the scalp EEG falls in the range of 1–20 Hz (activity below or above this range is likely to be artifactual, under standard clinical recording techniques). Waveforms are subdivided into bandwidths known as alpha, beta, theta, and delta to signify the majority of the EEG used in clinical practice.{{cite journal | vauthors = Tatum WO | title = Ellen R. Grass Lecture: extraordinary EEG | journal = The Neurodiagnostic Journal | volume = 54 | issue = 1 | pages = 3–21 | date = March 2014 | pmid = 24783746 }}

=Comparison of EEG bands=

class="wikitable"

|+ Comparison of EEG bands

BandFrequency (Hz)LocationNormallyPathologically
Delta

| < 4 || frontally in adults, posteriorly in children; high-amplitude waves||

  • adult slow-wave sleep
  • in babies
  • Has been found during some continuous-attention tasks{{cite journal | vauthors = Kirmizi-Alsan E, Bayraktaroglu Z, Gurvit H, Keskin YH, Emre M, Demiralp T | title = Comparative analysis of event-related potentials during Go/NoGo and CPT: decomposition of electrophysiological markers of response inhibition and sustained attention | journal = Brain Research | volume = 1104 | issue = 1 | pages = 114–128 | date = August 2006 | pmid = 16824492 | doi = 10.1016/j.brainres.2006.03.010 | s2cid = 18850757 }}

||

  • subcortical lesions
  • diffuse lesions
  • metabolic encephalopathy hydrocephalus
  • deep midline lesions
Theta

|4–7 || Found in locations not related to task at hand ||

  • higher in young children
  • drowsiness in adults and teens
  • idling
  • Associated with inhibition of elicited responses (has been found to spike in situations where a person is actively trying to repress a response or action).

||

  • focal subcortical lesions
  • metabolic encephalopathy
  • deep midline disorders
  • some instances of hydrocephalus
Alpha

| 8–12 || posterior regions of head, both sides, higher in amplitude on dominant side. Central sites (c3-c4) at rest ||

  • relaxed/reflecting
  • closing the eyes
  • Also associated with inhibition control, seemingly with the purpose of timing inhibitory activity in different locations across the brain.

||

  • coma
Beta

| 13–30 || both sides, symmetrical distribution, most evident frontally; low-amplitude waves ||

  • range span: active calm → intense → stressed → mild obsessive
  • active thinking, focus, high alert, anxious

||

  • benzodiazepines
  • Dup15q syndrome{{cite journal | vauthors = Frohlich J, Senturk D, Saravanapandian V, Golshani P, Reiter LT, Sankar R, Thibert RL, DiStefano C, Huberty S, Cook EH, Jeste SS | title = A Quantitative Electrophysiological Biomarker of Duplication 15q11.2-q13.1 Syndrome | journal = PLOS ONE | volume = 11 | issue = 12 | pages = e0167179 | date = December 2016 | pmid = 27977700 | pmc = 5157977 | doi = 10.1371/journal.pone.0167179 | author2-link = Damla Şentürk | doi-access = free | bibcode = 2016PLoSO..1167179F }}
Gamma

| > 32 || Somatosensory cortex ||

  • Displays during cross-modal sensory processing (perception that combines two different senses, such as sound and sight){{cite journal | vauthors = Kisley MA, Cornwell ZM | title = Gamma and beta neural activity evoked during a sensory gating paradigm: effects of auditory, somatosensory and cross-modal stimulation | journal = Clinical Neurophysiology | volume = 117 | issue = 11 | pages = 2549–2563 | date = November 2006 | pmid = 17008125 | pmc = 1773003 | doi = 10.1016/j.clinph.2006.08.003 }}{{cite journal | vauthors = Kanayama N, Sato A, Ohira H | title = Crossmodal effect with rubber hand illusion and gamma-band activity | journal = Psychophysiology | volume = 44 | issue = 3 | pages = 392–402 | date = May 2007 | pmid = 17371495 | doi = 10.1111/j.1469-8986.2007.00511.x }}
  • Also is shown during short-term memory matching of recognized objects, sounds, or tactile sensations

||

  • A decrease in gamma-band activity may be associated with cognitive decline, especially when related to the theta band; however, this has not been proven for use as a clinical diagnostic measurement
Mu

|8–12 || Sensorimotor cortex ||

  • Shows rest-state motor neurons.{{cite journal | vauthors = Gastaut H | title = [Electrocorticographic study of the reactivity of rolandic rhythm] | journal = Revue Neurologique | volume = 87 | issue = 2 | pages = 176–182 | year = 1952 | pmid = 13014777 }}

||

  • Mu suppression could indicate that motor mirror neurons are working. Deficits in Mu suppression, and thus in mirror neurons, might play a role in autism.{{cite journal | vauthors = Oberman LM, Hubbard EM, McCleery JP, Altschuler EL, Ramachandran VS, Pineda JA | title = EEG evidence for mirror neuron dysfunction in autism spectrum disorders | journal = Brain Research. Cognitive Brain Research | volume = 24 | issue = 2 | pages = 190–198 | date = July 2005 | pmid = 15993757 | doi = 10.1016/j.cogbrainres.2005.01.014 }}

The practice of using only whole numbers in the definitions comes from practical considerations in the days when only whole cycles could be counted on paper records. This leads to gaps in the definitions, as seen elsewhere on this page. The theoretical definitions have always been more carefully defined to include all frequencies. Unfortunately there is no agreement in standard reference works on what these ranges should be – values for the upper end of alpha and lower end of beta include 12, 13, 14 and 15. If the threshold is taken as 14 Hz, then the slowest beta wave has about the same duration as the longest spike (70 ms), which makes this the most useful value.

class="wikitable"

|+

File:Human EEG with prominent alpha-rhythm.png

=Wave patterns=

File:eeg delta.svgs|upright=2]]

  • Delta waves is the frequency range up to 4 Hz. It tends to be the highest in amplitude and the slowest waves. It is seen normally in adults in slow-wave sleep. It is also seen normally in babies. It may occur focally with subcortical lesions and in general distribution with diffuse lesions, metabolic encephalopathy hydrocephalus or deep midline lesions. It is usually most prominent frontally in adults (e.g. FIRDA – frontal intermittent rhythmic delta) and posteriorly in children (e.g. OIRDA – occipital intermittent rhythmic delta).

File:eeg theta.svg|upright=2]]

  • Theta is the frequency range from 4 Hz to 7 Hz. Theta is seen normally in young children. It may be seen in drowsiness or arousal in older children and adults; it can also be seen in meditation.{{cite journal | vauthors = Cahn BR, Polich J | title = Meditation states and traits: EEG, ERP, and neuroimaging studies | journal = Psychological Bulletin | volume = 132 | issue = 2 | pages = 180–211 | date = March 2006 | pmid = 16536641 | doi = 10.1037/0033-2909.132.2.180 | s2cid = 2151810 }} Excess theta for age represents abnormal activity. It can be seen as a focal disturbance in focal subcortical lesions; it can be seen in generalized distribution in diffuse disorder or metabolic encephalopathy or deep midline disorders or some instances of hydrocephalus. On the contrary this range has been associated with reports of relaxed, meditative, and creative states.

File:eeg alpha.svgs|upright=2]]

  • Alpha is the frequency range from 8 Hz to 12 Hz.{{cite journal | vauthors = Gerrard P, Malcolm R | title = Mechanisms of modafinil: A review of current research | journal = Neuropsychiatric Disease and Treatment | volume = 3 | issue = 3 | pages = 349–364 | date = June 2007 | pmid = 19300566 | pmc = 2654794 }} Hans Berger named the first rhythmic EEG activity he observed the "alpha wave". This was the "posterior basic rhythm" (also called the "posterior dominant rhythm" or the "posterior alpha rhythm"), seen in the posterior regions of the head on both sides, higher in amplitude on the dominant side. It emerges with closing of the eyes and with relaxation, and attenuates with eye opening or mental exertion. The posterior basic rhythm is actually slower than 8 Hz in young children (therefore technically in the theta range).

File:eeg SMR.svg aka mu rhythm|upright=2]]

:In addition to the posterior basic rhythm, there are other normal alpha rhythms such as the mu rhythm (alpha activity in the contralateral sensory and motor cortical areas) that emerges when the hands and arms are idle; and the "third rhythm" (alpha activity in the temporal or frontal lobes).{{cite journal | vauthors = Niedermeyer E | title = Alpha rhythms as physiological and abnormal phenomena | journal = International Journal of Psychophysiology | volume = 26 | issue = 1–3 | pages = 31–49 | date = June 1997 | pmid = 9202993 | doi = 10.1016/S0167-8760(97)00754-X | doi-access = free }}{{cite journal | vauthors = Feshchenko VA, Reinsel RA, Veselis RA | title = Multiplicity of the alpha rhythm in normal humans | journal = Journal of Clinical Neurophysiology | volume = 18 | issue = 4 | pages = 331–344 | date = July 2001 | pmid = 11673699 | doi = 10.1097/00004691-200107000-00005 }} Alpha can be abnormal; for example, an EEG that has diffuse alpha occurring in coma and is not responsive to external stimuli is referred to as "alpha coma".

File:eeg beta.svgs|upright=2]]

  • Beta is the frequency range from 13 Hz to about 30 Hz. It is seen usually on both sides in symmetrical distribution and is most evident frontally. Beta activity is closely linked to motor behavior and is generally attenuated during active movements.{{cite journal | vauthors = Pfurtscheller G, Lopes da Silva FH | title = Event-related EEG/MEG synchronization and desynchronization: basic principles | journal = Clinical Neurophysiology | volume = 110 | issue = 11 | pages = 1842–1857 | date = November 1999 | pmid = 10576479 | doi = 10.1016/S1388-2457(99)00141-8 | s2cid = 24756702 }} Low-amplitude beta with multiple and varying frequencies is often associated with active, busy or anxious thinking and active concentration. Rhythmic beta with a dominant set of frequencies is associated with various pathologies, such as Dup15q syndrome, and drug effects, especially benzodiazepines. It may be absent or reduced in areas of cortical damage. It is the dominant rhythm in patients who are alert or anxious or who have their eyes open.

File:eeg gamma.svgs|upright=2]]

  • Gamma is the frequency range approximately 30–100 Hz. Gamma rhythms are thought to represent binding of different populations of neurons together into a network for the purpose of carrying out a certain cognitive or motor function.
  • Mu range is 8–13 Hz and partly overlaps with other frequencies. It reflects the synchronous firing of motor neurons in rest state. Mu suppression is thought to reflect motor mirror neuron systems, because when an action is observed, the pattern extinguishes, possibly because the normal and mirror neuronal systems "go out of sync" and interfere with one other.

"Ultra-slow" or "near-DC" activity is recorded using DC amplifiers in some research contexts. It is not typically recorded in a clinical context because the signal at these frequencies is susceptible to a number of artifacts.

Some features of the EEG are transient rather than rhythmic. Spikes and sharp waves may represent seizure activity or interictal activity in individuals with epilepsy or a predisposition toward epilepsy. Other transient features are normal: vertex waves and sleep spindles are seen in normal sleep.

There are types of activity that are statistically uncommon, but not associated with dysfunction or disease. These are often referred to as "normal variants". The mu rhythm is an example of a normal variant.

The normal electroencephalogram (EEG) varies by age. The prenatal EEG and neonatal EEG is quite different from the adult EEG. Fetuses in the third trimester and newborns display two common brain activity patterns: "discontinuous" and "trace alternant." "Discontinuous" electrical activity refers to sharp bursts of electrical activity followed by low frequency waves. "Trace alternant" electrical activity describes sharp bursts followed by short high amplitude intervals and usually indicates quiet sleep in newborns.{{cite journal | vauthors = Anderson AL, Thomason ME | title = Functional plasticity before the cradle: a review of neural functional imaging in the human fetus | journal = Neuroscience and Biobehavioral Reviews | volume = 37 | issue = 9 Pt B | pages = 2220–2232 | date = November 2013 | pmid = 23542738 | doi = 10.1016/j.neubiorev.2013.03.013 | s2cid = 45733681 }} The EEG in childhood generally has slower frequency oscillations than the adult EEG.

The normal EEG also varies depending on state. The EEG is used along with other measurements (EOG, EMG) to define sleep stages in polysomnography. Stage I sleep (equivalent to drowsiness in some systems) appears on the EEG as drop-out of the posterior basic rhythm. There can be an increase in theta frequencies. Santamaria and Chiappa cataloged a number of the variety of patterns associated with drowsiness. Stage II sleep is characterized by sleep spindles – transient runs of rhythmic activity in the 12–14 Hz range (sometimes referred to as the "sigma" band) that have a frontal-central maximum. Most of the activity in Stage II is in the 3–6 Hz range. Stage III and IV sleep are defined by the presence of delta frequencies and are often referred to collectively as "slow-wave sleep". Stages I–IV comprise non-REM (or "NREM") sleep. The EEG in REM (rapid eye movement) sleep appears somewhat similar to the awake EEG.

EEG under general anesthesia depends on the type of anesthetic employed. With halogenated anesthetics, such as halothane or intravenous agents, such as propofol, a rapid (alpha or low beta), nonreactive EEG pattern is seen over most of the scalp, especially anteriorly; in some older terminology this was known as a WAR (widespread anterior rapid) pattern, contrasted with a WAIS (widespread slow) pattern associated with high doses of opiates. Anesthetic effects on EEG signals are beginning to be understood at the level of drug actions on different kinds of synapses and the circuits that allow synchronized neuronal activity.{{cite web | title = The MacIver Lab | url = http://www.stanford.edu/group/maciverlab/ | publisher = Stanford University | access-date = December 16, 2006 | archive-date = November 23, 2008 | archive-url = https://web.archive.org/web/20081123211653/http://www.stanford.edu/group/maciverlab/ | url-status = live }} Recent algorithms based on state-chart representation using EEG signals can now to monitor the brain states during general anesthesia allowing to classify the brain depth under various sedation.{{Cite journal |last1=Loison |first1=V. |last2=Voskobiynyk |first2=Y. |last3=Lindquist |first3=B. |last4=Necula |first4=D. |last5=Longrois |first5=D. |last6=Paz |first6=J. |last7=Holcman |first7=D. |date=2024-01-01 |title=Mapping general anesthesia states based on electro-encephalogram transition phases |journal=NeuroImage |volume=285 |pages=120498 |doi=10.1016/j.neuroimage.2023.120498 |pmid=38135170 |issn=1053-8119|pmc=10792552 }}

Artifacts

{{Redirect|Breach effect|the birth position|breech birth}}

File:Human EEG artefacts.png

EEG is an extremely useful technique for studying brain activity, but the signal measured is always contaminated by artifacts which can impact the analysis of the data. An artifact is any measured signal that does not originate within the brain. Although multiple algorithms exist for the removal of artifacts, the problem of how to deal with them remains an open question. The source of artifacts can be from issues relating to the instrument, such as faulty electrodes, line noise or high electrode impedance, or they may be from the physiology of the subject being recorded. This can include, eye blinks and movement, cardiac activity and muscle activity and these types of artifacts are more complicated to remove. Artifacts may bias the visual interpretation of EEG data as some may mimic cognitive activity that could affect diagnoses of problems such as Alzheimer's disease or sleep disorders. As such the removal of such artifacts in EEG data used for practical applications is of the utmost importance.{{cite journal | vauthors = Jiang X, Bian GB, Tian Z | title = Removal of Artifacts from EEG Signals: A Review | journal = Sensors | volume = 19 | issue = 5 | pages = 987 | date = February 2019 | pmid = 30813520 | pmc = 6427454 | doi = 10.3390/s19050987 | doi-access = free | bibcode = 2019Senso..19..987J }}

= Artifact removal =

It is important to be able to distinguish artifacts from genuine brain activity in order to prevent incorrect interpretations of EEG data. General approaches for the removal of artifacts from the data are, prevention, rejection and cancellation. The goal of any approach is to develop methodology capable of identifying and removing artifacts without affecting the quality of the EEG signal. As artifact sources are quite different the majority of researchers focus on developing algorithms that will identify and remove a single type of noise in the signal. Simple filtering using a notch filter is commonly employed to reject components with a 50/60 Hz frequency. However such simple filters are not an appropriate choice for dealing with all artifacts, as for some, their frequencies will overlap with the EEG frequencies.

Regression algorithms have a moderate computation cost and are simple. They represented the most popular correction method up until the mid-1990s when they were replaced by "blind source separation" type methods. Regression algorithms work on the premise that all artifacts are comprised by one or more reference channels. Subtracting these reference channels from the other contaminated channels, in either the time or frequency domain, by estimating the impact of the reference channels on the other channels, would correct the channels for the artifact. Although the requirement of reference channels ultimately lead to this class of algorithm being replaced, they still represent the benchmark against which modern algorithms are evaluated.{{Cite journal | vauthors = Alsuradi H, Park W, Eid M |date=2020 |title=EEG-Based Neurohaptics Research: A Literature Review |journal=IEEE Access |volume=8 |pages=49313–49328 |doi=10.1109/ACCESS.2020.2979855 |bibcode=2020IEEEA...849313A |s2cid=214596892 |issn=2169-3536 |doi-access=free }}

Blind source separation (BSS) algorithms employed to remove artifacts include principal component analysis (PCA) and independent component analysis (ICA) and several algorithms in this class have been successful at tackling most physiological artifacts. Recent real-time algorithms based on wavelet transport called WQN can now be used to find and replace artifact segment in real-time in the absence of artifact information. These classes of algorithms depend on the continuity of spectral energy in the different frequency [https://www.sciencedirect.com/science/article/abs/pii/S1063520322000616 bands]{{Cite journal |last1=Dora |first1=Matteo |last2=Holcman |first2=David |date=2022 |title=Adaptive Single-Channel EEG Artifact Removal With Applications to Clinical Monitoring |journal=IEEE Transactions on Neural Systems and Rehabilitation Engineering |volume=30 |pages=286–295 |doi=10.1109/TNSRE.2022.3147072 |issn=1558-0210|doi-access=free |pmid=35085086 }}{{Cite journal |last1=Dora |first1=Matteo |last2=Jaffard |first2=Stéphane |last3=Holcman |first3=David |date=2024 |title=The WQN Algorithm for EEG Artifact Removal in the Absence of Scale Invariance |url=https://ieeexplore.ieee.org/document/10542728 |journal=IEEE Transactions on Signal Processing |volume=72 |pages=2663–2676 |doi=10.1109/TSP.2024.3403965 |issn=1941-0476|arxiv=2307.04155 |bibcode=2024ITSP...72.2663D }}

= Physiological artifacts =

== Ocular artifacts ==

Ocular artifacts affect the EEG signal significantly. This is due to eye movements involving a change in electric fields surrounding the eyes, distorting the electric field over the scalp, and as EEG is recorded on the scalp, it therefore distorts the recorded signal. A difference of opinion exists among researchers, with some arguing ocular artifacts are, or may be reasonably described as a single generator, whilst others argue it is important to understand the potentially complicated mechanisms. Three potential mechanisms have been proposed to explain the ocular artifact.

The first is corneal retinal dipole movement which argues that an electric dipole is formed between the cornea and retina, as the former is positively and the latter negatively charged. When the eye moves, so does this dipole which impacts the electrical field over the scalp, this is the most standard view. The second mechanism is retinal dipole movement, which is similar to the first but differing in that it argues there is a potential difference, hence dipole across the retina with the cornea having little effect. The third mechanism is eyelid movement. It is known that there is a change in voltage around the eyes when the eyelid moves, even if the eyeball does not. It is thought that the eyelid can be described as a sliding potential source and that the impacting of blinking is different to eye movement on the recorded EEG.{{cite journal | vauthors = Croft RJ, Barry RJ | title = Removal of ocular artifact from the EEG: a review | journal = Clinical Neurophysiology | volume = 30 | issue = 1 | pages = 5–19 | date = February 2000 | pmid = 10740792 | doi = 10.1016/S0987-7053(00)00055-1 | s2cid = 13738373 }}

Eyelid fluttering artifacts of a characteristic type were previously called Kappa rhythm (or Kappa waves). It is usually seen in the prefrontal leads, that is, just over the eyes. Sometimes they are seen with mental activity. They are usually in the Theta (4–7 Hz) or Alpha (7–14 Hz) range. They were named because they were believed to originate from the brain. Later study revealed they were generated by rapid fluttering of the eyelids, sometimes so minute that it was difficult to see. They are in fact noise in the EEG reading, and should not technically be called a rhythm or wave. Therefore, current usage in electroencephalography refers to the phenomenon as an eyelid fluttering artifact, rather than a Kappa rhythm (or wave).{{cite book |title=Introduction to EEG and evoked potentials |vauthors=Epstein CM |publisher=J. B. Lippincott Co. |year=1983 |isbn=978-0-397-50598-2}}{{page needed|date=August 2013}}

The propagation of the ocular artifact is impacted by multiple factors including the properties of the subject's skull, neuronal tissues and skin but the signal may be approximated as being inversely proportional to the distance from the eyes squared. The electrooculogram (EOG) consists of a series of electrodes measuring voltage changes close to the eye and is the most common tool for dealing with the eye movement artifact in the EEG signal.

== Muscular artifacts ==

Another source of artifacts are various muscle movements across the body. This particular class of artifact is usually recorded by all electrodes on the scalp due to myogenic activity (increase or decrease of blood pressure). The origin of these artifacts have no single location and arises from functionally independent muscle groups, meaning the characteristics of the artifact are not constant. The observed patterns due to muscular artifacts will change depending on subject sex, the particular muscle tissue, and its degree of contraction. The frequency range for muscular artifacts is wide and overlaps with every classic EEG rhythm. However most of the power is concentrated in the lower range of the observed frequencies of 20 to 300 Hz making the gamma band particularly susceptible to muscular artifacts. Some muscle artifacts may have activity with a frequency as low as 2 Hz, so delta and theta bands may also be affected by muscle activity. Muscular artifacts may impact sleep studies, as unconscious bruxism (grinding of teeth) movements or snoring can seriously impact the quality of the recorded EEG. In addition the recordings made of epilepsy patients may be significantly impacted by the existence of muscular artifacts.{{Cite journal | vauthors = Chen X, Xu X, Liu A, Lee S, Chen X, Zhang X, McKeown MJ, Wang ZJ |date=July 15, 2019 |title=Removal of Muscle Artifacts From the EEG: A Review and Recommendations |url=https://ieeexplore.ieee.org/document/8672623/;jsessionid=As8tSBB9oaPfg094BVG92B-t9gaUdCy8m_HKmEdHJLX-Z_Ch3boQ!-508844548 |journal=IEEE Sensors Journal |volume=19 |issue=14 |pages=5353–5368 |doi=10.1109/JSEN.2019.2906572 |bibcode=2019ISenJ..19.5353C |s2cid=116693954 |issn=1558-1748}}

== Cardiac artifacts ==

The potential due to cardiac activity introduces electrocardiograph (ECG) errors in the EEG.{{Citation | vauthors = Kaya I |title=Brain-Computer Interface |chapter=A Brief Summary of EEG Artifact Handling |date=May 18, 2022 |chapter-url=https://www.intechopen.com/chapters/77731 |series=Artificial Intelligence |volume=9 | veditors = Asadpour V |publisher=IntechOpen |language=en |doi=10.5772/intechopen.99127 |isbn=978-1-83962-522-0 |s2cid=209832569 |access-date=December 20, 2022 |archive-date=December 20, 2022 |archive-url=https://web.archive.org/web/20221220022603/https://www.intechopen.com/chapters/77731 |url-status=live |doi-access=free |arxiv=2001.00693 }} Artifacts arising due to cardiac activity may be removed with the help of an ECG reference signal.

== Other physiological artifacts ==

Glossokinetic artifacts are caused by the potential difference between the base and the tip of the tongue. Minor tongue movements can contaminate the EEG, especially in parkinsonian and tremor disorders.{{Citation needed|date=December 2022}}

=Environmental artifacts=

In addition to artifacts generated by the body, many artifacts originate from outside the body. Movement by the patient, or even just settling of the electrodes, may cause electrode pops, spikes originating from a momentary change in the impedance of a given electrode. Poor grounding of the EEG electrodes can cause significant 50 or 60 Hz artifact, depending on the local power system's frequency. A third source of possible interference can be the presence of an IV drip; such devices can cause rhythmic, fast, low-voltage bursts, which may be confused for spikes.{{Citation needed|date=January 2023}}

Abnormal activity

Abnormal activity can broadly be separated into epileptiform and non-epileptiform activity. It can also be separated into focal or diffuse.

Focal epileptiform discharges represent fast, synchronous potentials in a large number of neurons in a somewhat discrete area of the brain. These can occur as interictal activity, between seizures, and represent an area of cortical irritability that may be predisposed to producing epileptic seizures. Interictal discharges are not wholly reliable for determining whether a patient has epilepsy nor where his/her seizure might originate. (See focal epilepsy.)

Generalized epileptiform discharges often have an anterior maximum, but these are seen synchronously throughout the entire brain. They are strongly suggestive of a generalized epilepsy.

Focal non-epileptiform abnormal activity may occur over areas of the brain where there is focal damage of the cortex or white matter. It often consists of an increase in slow frequency rhythms or a loss of normal higher frequency rhythms. It may also appear as focal or unilateral decrease in amplitude of the EEG signal.

Diffuse non-epileptiform abnormal activity may manifest as diffuse abnormally slow rhythms or bilateral slowing of normal rhythms, such as the PBR.

Intracortical Encephalogram electrodes and sub-dural electrodes can be used in tandem to discriminate and discretize artifact from epileptiform and other severe neurological events.

More advanced measures of abnormal EEG signals have also recently received attention as possible biomarkers for different disorders such as Alzheimer's disease.{{cite journal | vauthors = Montez T, Poil SS, Jones BF, Manshanden I, Verbunt JP, van Dijk BW, Brussaard AB, van Ooyen A, Stam CJ, Scheltens P, Linkenkaer-Hansen K | title = Altered temporal correlations in parietal alpha and prefrontal theta oscillations in early-stage Alzheimer disease | journal = Proceedings of the National Academy of Sciences of the United States of America | volume = 106 | issue = 5 | pages = 1614–1619 | date = February 2009 | pmid = 19164579 | pmc = 2635782 | doi = 10.1073/pnas.0811699106 | bibcode = 2009PNAS..106.1614M | doi-access = free }}

=Remote communication=

Systems for decoding imagined speech from EEG have applications such as in brain–computer interfaces.{{cite journal | vauthors = Panachakel JT, Ramakrishnan AG | title = Decoding Covert Speech From EEG-A Comprehensive Review | language = English | journal = Frontiers in Neuroscience | volume = 15 | pages = 642251 | date = 2021 | pmid = 33994922 | pmc = 8116487 | doi = 10.3389/fnins.2021.642251 | doi-access = free }}

= EEG diagnostics =

The Department of Defense (DoD) and Veteran's Affairs (VA), and U.S Army Research Laboratory (ARL), collaborated on EEG diagnostics in order to detect mild to moderate Traumatic Brain Injury (mTBI) in combat soldiers.{{cite journal | vauthors = Rapp PE, Keyser DO, Albano A, Hernandez R, Gibson DB, Zambon RA, Hairston WD, Hughes JD, Krystal A, Nichols AS | title = Traumatic brain injury detection using electrophysiological methods | journal = Frontiers in Human Neuroscience | volume = 9 | pages = 11 | date = 2015 | pmid = 25698950 | pmc = 4316720 | doi = 10.3389/fnhum.2015.00011 | doi-access = free }} Between 2000 and 2012, 75 percent of U.S. military operations brain injuries were classified mTBI. In response, the DoD pursued new technologies capable of rapid, accurate, non-invasive, and field-capable detection of mTBI to address this injury.

Combat personnel often develop PTSD and mTBI in correlation. Both conditions present with altered low-frequency brain wave oscillations.{{cite journal | vauthors = Franke LM, Walker WC, Hoke KW, Wares JR | title = Distinction in EEG slow oscillations between chronic mild traumatic brain injury and PTSD | journal = International Journal of Psychophysiology | volume = 106 | pages = 21–29 | date = August 2016 | pmid = 27238074 | doi = 10.1016/j.ijpsycho.2016.05.010 }} Altered brain waves from PTSD patients present with decreases in low-frequency oscillations, whereas, mTBI injuries are linked to increased low-frequency wave oscillations. Effective EEG diagnostics can help doctors accurately identify conditions and appropriately treat injuries in order to mitigate long-term effects.{{Cite web|url=https://www.research.va.gov/currents/1116-2.cfm|title=Study: EEG can help tell apart PTSD, mild traumatic brain injury|website=www.research.va.gov|access-date=October 9, 2019|archive-date=October 9, 2019|archive-url=https://web.archive.org/web/20191009195224/https://www.research.va.gov/currents/1116-2.cfm|url-status=live}}

Traditionally, clinical evaluation of EEGs involved visual inspection. Instead of a visual assessment of brain wave oscillation topography, quantitative electroencephalography (qEEG), computerized algorithmic methodologies, analyzes a specific region of the brain and transforms the data into a meaningful "power spectrum" of the area. Accurately differentiating between mTBI and PTSD can significantly increase positive recovery outcomes for patients especially since long-term changes in neural communication can persist after an initial mTBI incident.

Another common measurement made from EEG data is that of complexity measures such as Lempel-Ziv complexity, fractal dimension, and spectral flatness, which are associated with particular pathologies or pathology stages.

Economics

Inexpensive EEG devices exist for the low-cost research and consumer markets. Recently, a few companies have miniaturized medical grade EEG technology to create versions accessible to the general public. Some of these companies have built commercial EEG devices retailing for less than US$100.

  • In 2004 OpenEEG released its ModularEEG as open source hardware. Compatible open source software includes a game for balancing a ball.
  • In 2007 NeuroSky released the first affordable consumer based EEG along with the game NeuroBoy. This was also the first large scale EEG device to use dry sensor technology.{{cite news |url= http://www.economist.com/science/displaystory.cfm?story_id=8847846 |title= Mind Games |date= March 23, 2007 |publisher= The Economist |access-date= August 12, 2010 |archive-date= December 12, 2009 |archive-url= https://web.archive.org/web/20091212220903/http://www.economist.com/science/displaystory.cfm?story_id=8847846 |url-status= live }}
  • In 2008 OCZ Technology developed device for use in video games relying primarily on electromyography.
  • In 2008 the Final Fantasy developer Square Enix announced that it was partnering with NeuroSky to create a game, Judecca.{{cite news|url=https://www.latimes.com/business/la-fi-mind-reader-20100808,0,6235181,full.story|archive-url=https://archive.today/20130104065206/http://www.latimes.com/business/la-fi-mind-reader-20100808,0,6235181,full.story|url-status=dead|archive-date=January 4, 2013|title= Mind reading is on the market |date=August 8, 2010 |work=Los Angeles Times | vauthors = Li S }}{{cite web |vauthors=Fruhlinger J |date=October 9, 2008 |url=https://www.engadget.com/2008/10/09/brains-on-with-neurosky-and-squareenixs-judecca-mind-control-ga/ |title=Brains-on with NeuroSky and Square Enix's Judecca mind-control game |publisher=Engadget |access-date=December 2, 2010 |archive-date=October 30, 2010 |archive-url=https://web.archive.org/web/20101030014828/http://www.engadget.com/2008/10/09/brains-on-with-neurosky-and-squareenixs-judecca-mind-control-ga/ |url-status=live }}
  • In 2009 Mattel partnered with NeuroSky to release the Mindflex, a game that used an EEG to steer a ball through an obstacle course. By far the best-selling consumer based EEG to date.{{cite web|url=http://www.physorg.com/news150781868.html |title=New games powered by brain waves |publisher=Physorg.com |access-date=December 2, 2010 |url-status=dead |archive-url=https://web.archive.org/web/20110606080916/http://www.physorg.com/news150781868.html |archive-date=June 6, 2011 }}
  • In 2009 Uncle Milton Industries partnered with NeuroSky to release the Star Wars Force Trainer, a game designed to create the illusion of possessing the Force.{{cite news | url=https://www.usatoday.com/life/lifestyle/2009-01-06-force-trainer-toy_N.htm | work=USA Today | title=Toy trains 'Star Wars' fans to use The Force | vauthors=Snider M | date=January 7, 2009 | access-date=May 1, 2010 | archive-date=October 23, 2012 | archive-url=https://web.archive.org/web/20121023104506/https://usatoday30.usatoday.com/life/lifestyle/2009-01-06-force-trainer-toy_N.htm | url-status=live }}
  • In 2010, NeuroSky added a blink and electromyography function to the MindSet.{{cite web |url=http://www.gamasutra.com/view/news/29190/NeuroSky_Upgrades_SDK_Allows_For_Eye_Blink_BrainwavePowered_Games.php |title=News – NeuroSky Upgrades SDK, Allows For Eye Blink, Brainwave-Powered Games |publisher=Gamasutra |date=June 30, 2010 |access-date=December 2, 2010 |archive-date=February 22, 2017 |archive-url=https://web.archive.org/web/20170222053401/http://www.gamasutra.com/view/news/29190/NeuroSky_Upgrades_SDK_Allows_For_Eye_Blink_BrainwavePowered_Games.php |url-status=dead }}
  • In 2011, NeuroSky released the MindWave, an EEG device designed for educational purposes and games.{{cite web |url= http://www.ubergizmo.com/2011/03/neurosky-mindwave/ |title= NeuroSky MindWave Brings Brain-Computer Interface to Education |vauthors= Fiolet E |website= www.ubergizmo.com |publisher= Ubergizmo |access-date= May 18, 2015 |archive-date= December 12, 2017 |archive-url= https://web.archive.org/web/20171212142303/http://www.ubergizmo.com/2011/03/neurosky-mindwave/ |url-status= live }} The MindWave won the Guinness Book of World Records award for "Heaviest machine moved using a brain control interface".{{cite web|url= http://neurogadget.com/2011/04/12/neurosky-mindwave-sets-guinness-world-record-for-%E2%80%9Clargest-object-moved-using-a-brain-computer-interface%E2%80%9D/1820|title= NeuroSky MindWave Sets Guinness World Record for "Largest Object Moved Using a Brain-Computer Interface"|website= NeuroGadget.com|publisher= NeuroGadget|access-date= June 2, 2011|archive-url= https://web.archive.org/web/20131015064018/http://neurogadget.com/2011/04/12/neurosky-mindwave-sets-guinness-world-record-for-%E2%80%9Clargest-object-moved-using-a-brain-computer-interface%E2%80%9D/1820|archive-date= October 15, 2013|url-status= dead}}
  • In 2012, a Japanese gadget project, neurowear, released Necomimi: a headset with motorized cat ears. The headset is a NeuroSky MindWave unit with two motors on the headband where a cat's ears might be. Slipcovers shaped like cat ears sit over the motors so that as the device registers emotional states the ears move to relate. For example, when relaxed, the ears fall to the sides and perk up when excited again.
  • In 2014, OpenBCI released an eponymous open source brain-computer interface after a successful kickstarter campaign in 2013. The board, later renamed "Cyton", has 8 channels, expandable to 16 with the Daisy module. It supports EEG, EKG, and EMG. The Cyton Board is based on the Texas Instruments ADS1299 IC and the Arduino or PIC microcontroller, and initially costed $399 before increasing in price to $999. It uses standard metal cup electrodes and conductive paste.
  • In 2015, Mind Solutions Inc released the smallest consumer BCI to date, the NeuroSync. This device functions as a dry sensor at a size no larger than a Bluetooth ear piece.{{cite web|title=Product Launch! Neurosync – The World's Smallest Brain-Computer-Interface|url=http://www.prnewswire.com/news-releases/product-launch-neurosync---the-worlds-smallest-brain-computer-interface-300113433.html|website=www.prnewswire.com|access-date=July 21, 2017|language=en|date=July 15, 2015|archive-date=December 9, 2018|archive-url=https://web.archive.org/web/20181209221332/https://www.prnewswire.com/news-releases/product-launch-neurosync---the-worlds-smallest-brain-computer-interface-300113433.html|url-status=live}}
  • In 2015, A Chinese-based company Macrotellect released BrainLink Pro and BrainLink Lite, a consumer grade EEG wearable product providing 20 brain fitness enhancement Apps on Apple and Android App Stores.{{Cite web|url=http://o.macrotellect.com/app.html|title=APP – Macrotellect|website=o.macrotellect.com|access-date=December 8, 2016|archive-date=January 23, 2017|archive-url=https://web.archive.org/web/20170123204243/http://o.macrotellect.com/app.html|url-status=live}}
  • In 2021, BioSerenity release the Neuronaute and Icecap a single-use disposable EEG headset that allows recording with equivalent quality to traditional cup electrodes.{{Cite web|title=510(k) Premarket Notification|url=https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K202334|access-date=November 12, 2021|website=www.accessdata.fda.gov|archive-date=November 12, 2021|archive-url=https://web.archive.org/web/20211112211158/https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K202334|url-status=live}}{{Cite web| veditors = Bell J |date=January 8, 2021|title=BioSerenity receives FDA clearance for EEG wearable device system|url=https://neuronewsinternational.com/bioserenity-receives-fda-clearance-for-eeg-wearable-device-system/|access-date=November 12, 2021|website=NeuroNews International|language=en-GB|archive-date=November 12, 2021|archive-url=https://web.archive.org/web/20211112211156/https://neuronewsinternational.com/bioserenity-receives-fda-clearance-for-eeg-wearable-device-system/|url-status=live}}

Future research

{{Primary sources|section|date=May 2012}}

The EEG has been used for many purposes besides the conventional uses of clinical diagnosis and conventional cognitive neuroscience. An early use was during World War II by the U.S. Army Air Corps to screen out pilots in danger of having seizures;{{cite journal | vauthors = Keiper A | title = The age of neuroelectronics | journal = New Atlantis | volume = 11 | pages = 4–41 | year = 2006 | pmid = 16789311 | url = http://www.thenewatlantis.com/publications/the-age-of-neuroelectronics | url-status = dead | publisher = The New Atlantis | archive-url = https://web.archive.org/web/20160212222927/http://www.thenewatlantis.com/publications/the-age-of-neuroelectronics | archive-date = February 12, 2016 }} long-term EEG recordings in epilepsy patients are still used today for seizure prediction. Neurofeedback remains an important extension, and in its most advanced form is also attempted as the basis of brain computer interfaces.{{cite journal | vauthors = Wan F, da Cruz JN, Nan W, Wong CM, Vai MI, Rosa A | title = Alpha neurofeedback training improves SSVEP-based BCI performance | journal = Journal of Neural Engineering | volume = 13 | issue = 3 | pages = 036019 | date = June 2016 | pmid = 27152666 | doi = 10.1088/1741-2560/13/3/036019 | s2cid = 206099640 | bibcode = 2016JNEng..13c6019W | url = http://infoscience.epfl.ch/record/218357 }} The EEG is also used quite extensively in the field of neuromarketing.

The EEG is altered by drugs that affect brain functions, the chemicals that are the basis for psychopharmacology. Berger's early experiments recorded the effects of drugs on EEG. The science of pharmaco-electroencephalography has developed methods to identify substances that systematically alter brain functions for therapeutic and recreational use.

Honda is attempting to develop a system to enable an operator to control its Asimo robot using EEG, a technology it eventually hopes to incorporate into its automobiles.{{cite web | url = http://search.japantimes.co.jp/cgi-bin/nb20090401a2.html | title = Mind over matter: Brain waves control Asimo | archive-url = https://web.archive.org/web/20090403021412/http://search.japantimes.co.jp/cgi-bin/nb20090401a2.html | archive-date=April 3, 2009 | date = April 1, 2009 | work = Japan Times }}

EEGs have been used as evidence in criminal trials in the Indian state of Maharashtra.{{cite web | url = https://timesofindia.indiatimes.com/city/mumbai/This-brain-test-maps-the-truth/articleshow/3257032.cms | title = This brain test maps the truth | date = July 21, 2008 | vauthors = Natu N | work = The Times of India | access-date = April 14, 2021 | archive-date = July 18, 2012 | archive-url = https://archive.today/20120718100522/http://articles.timesofindia.indiatimes.com/2008-07-21/mumbai/27890043_1_sessions-court-murder-rukmani-krishnamurthy | url-status = live }}{{cite conference | vauthors = Puranik DA, Joseph SK, Daundkar BB, Garad MV | title = Brain Signature Profiling In India: Its Status As An Aid In Investigation And As Corroborative Evidence-As Seen From Judgments. | conference = Proceedings of XX All India Forensic Science Conference | date = November 2009 | pages = 815–822 | url = http://forensic-centre.com/wp-content/uploads/2013/07/BEOS-IN-INDIA-IT_222S-STATUS-AS-AN-AID-IN-INVESTIGATION-AND-AS-CORROBORATIVE-EVIDENCE-AS-SEEN-FROM-JUDGMENTS_.pdf |archive-url=https://web.archive.org/web/20160303223045/http://forensic-centre.com/wp-content/uploads/2013/07/BEOS-IN-INDIA-IT_222S-STATUS-AS-AN-AID-IN-INVESTIGATION-AND-AS-CORROBORATIVE-EVIDENCE-AS-SEEN-FROM-JUDGMENTS_.pdf |archive-date=March 3, 2016 |url-status=dead }} Brain Electrical Oscillation Signature Profiling (BEOS), an EEG technique, was used in the trial of State of Maharashtra v. Sharma to show Sharma remembered using arsenic to poison her ex-fiancé, although the reliability and scientific basis of BEOS is disputed.{{cite journal |vauthors=Gaudet LM |title=Brain Fingerprinting, Scientific Evidence, and "Daubert": A Cautionary Lesson from India |journal=Jurimetrics |date=2011 |volume=51 |issue=3 |pages=293–318 |jstor=41307131 |url=https://www.jstor.org/stable/41307131 |issn=0897-1277 |access-date=March 20, 2019 |archive-date=April 16, 2021 |archive-url=https://web.archive.org/web/20210416072703/https://www.jstor.org/stable/41307131 |url-status=live }}

A lot of research is currently being carried out in order to make EEG devices smaller, more portable and easier to use. So called "Wearable EEG" is based upon creating low power wireless collection electronics and 'dry' electrodes which do not require a conductive gel to be used.{{cite journal | vauthors = Casson A, Yates D, Smith S, Duncan J, Rodriguez-Villegas E | title = Wearable electroencephalography. What is it, why is it needed, and what does it entail? | journal = IEEE Engineering in Medicine and Biology Magazine | volume = 29 | issue = 3 | pages = 44–56 | year = 2010 | pmid = 20659857 | doi = 10.1109/MEMB.2010.936545 | hdl-access = free | s2cid = 1891995 | hdl = 10044/1/5910 }} Wearable EEG aims to provide small EEG devices which are present only on the head and which can record EEG for days, weeks, or months at a time, as ear-EEG. Such prolonged and easy-to-use monitoring could make a step change in the diagnosis of chronic conditions such as epilepsy, and greatly improve the end-user acceptance of BCI systems.{{cite journal | vauthors = Looney D, Kidmose P, Park C, Ungstrup M, Rank M, Rosenkranz K, Mandic D | title = The in-the-ear recording concept: user-centered and wearable brain monitoring | journal = IEEE Pulse | volume = 3 | issue = 6 | pages = 32–42 | date = November 1, 2012 | pmid = 23247157 | doi = 10.1109/MPUL.2012.2216717 | s2cid = 14103460 }} Research is also being carried out on identifying specific solutions to increase the battery lifetime of Wearable EEG devices through the use of the data reduction approach.

In research, currently EEG is often used in combination with machine learning.{{cite journal | vauthors = Lotte F, Bougrain L, Cichocki A, Clerc M, Congedo M, Rakotomamonjy A, Yger F | title = A review of classification algorithms for EEG-based brain-computer interfaces: a 10 year update | journal = Journal of Neural Engineering | volume = 15 | issue = 3 | pages = 031005 | date = June 2018 | pmid = 29488902 | doi = 10.1088/1741-2552/aab2f2 | doi-access = free | bibcode = 2018JNEng..15c1005L }} EEG data are pre-processed then passed on to machine learning algorithms. These algorithms are then trained to recognize different diseases like schizophrenia,{{cite journal | vauthors = Shim M, Hwang HJ, Kim DW, Lee SH, Im CH | title = Machine-learning-based diagnosis of schizophrenia using combined sensor-level and source-level EEG features | journal = Schizophrenia Research | volume = 176 | issue = 2–3 | pages = 314–319 | date = October 2016 | pmid = 27427557 | doi = 10.1016/j.schres.2016.05.007 | s2cid = 44504680 }} epilepsy{{Cite journal|vauthors=Buettner R, Frick J, Rieg T|date=November 12, 2019|title=High-performance detection of epilepsy in seizure-free EEG recordings: A novel machine learning approach using very specific epileptic EEG sub-bands|url=https://aisel.aisnet.org/icis2019/is_health/is_health/16|journal=ICIS 2019 Proceedings|access-date=January 13, 2021|archive-date=January 21, 2021|archive-url=https://web.archive.org/web/20210121014450/https://aisel.aisnet.org/icis2019/is_health/is_health/16/|url-status=live}} or dementia.{{cite journal | vauthors = Ieracitano C, Mammone N, Hussain A, Morabito FC | title = A novel multi-modal machine learning based approach for automatic classification of EEG recordings in dementia | journal = Neural Networks | volume = 123 | pages = 176–190 | date = March 2020 | pmid = 31884180 | doi = 10.1016/j.neunet.2019.12.006 | s2cid = 209510497 }} Furthermore, they are increasingly used to study seizure detection.{{cite journal | vauthors = Bhattacharyya A, Pachori RB | title = A Multivariate Approach for Patient-Specific EEG Seizure Detection Using Empirical Wavelet Transform | journal = IEEE Transactions on Bio-Medical Engineering | volume = 64 | issue = 9 | pages = 2003–2015 | date = September 2017 | pmid = 28092514 | doi = 10.1109/TBME.2017.2650259 | s2cid = 3522546 }}{{cite journal | vauthors = Saab K, Dunnmon J, Ré C, Rubin D, Lee-Messer C | title = Weak supervision as an efficient approach for automated seizure detection in electroencephalography | journal = npj Digital Medicine | volume = 3 | issue = 1 | pages = 59 | date = April 20, 2020 | pmid = 32352037 | pmc = 7170880 | doi = 10.1038/s41746-020-0264-0 | doi-access = free }}{{cite journal | vauthors = Bomela W, Wang S, Chou CA, Li JS | title = Real-time Inference and Detection of Disruptive EEG Networks for Epileptic Seizures | journal = Scientific Reports | volume = 10 | issue = 1 | pages = 8653 | date = May 2020 | pmid = 32457378 | pmc = 7251100 | doi = 10.1038/s41598-020-65401-6 | doi-access = free | bibcode = 2020NatSR..10.8653B }}{{cite journal | vauthors = Paesschen WV | title = The future of seizure detection | journal = The Lancet. Neurology | volume = 17 | issue = 3 | pages = 200–202 | date = March 2018 | pmid = 29452676 | doi = 10.1016/S1474-4422(18)30034-6 | s2cid = 3376296 }} By using machine learning, the data can be analyzed automatically. In the long run this research is intended to build algorithms that support physicians in their clinical practice{{cite journal | vauthors = Chen PC, Liu Y, Peng L | title = How to develop machine learning models for healthcare | journal = Nature Materials | volume = 18 | issue = 5 | pages = 410–414 | date = May 2019 | pmid = 31000806 | doi = 10.1038/s41563-019-0345-0 | s2cid = 122563425 | bibcode = 2019NatMa..18..410C }} and to provide further insights into diseases.{{cite journal | vauthors = Rudin C | title = Stop Explaining Black Box Machine Learning Models for High Stakes Decisions and Use Interpretable Models Instead | journal = Nature Machine Intelligence | volume = 1 | issue = 5 | pages = 206–215 | date = May 2019 | pmid = 35603010 | pmc = 9122117 | doi = 10.1038/s42256-019-0048-x | arxiv = 1811.10154 | doi-access = free }} In this vein, complexity measures of EEG data are often calculated, such as Lempel-Ziv complexity, fractal dimension, and spectral flatness. It has been shown that combining or multiplying such measures can reveal previously hidden information in EEG data.

EEG signals from musical performers were used to create instant compositions and one CD by the Brainwave Music Project, run at the Computer Music Center at Columbia University by Brad Garton and Dave Soldier.{{Citation needed|date=January 2023}} Similarly, an hour-long recording of the brainwaves of Ann Druyan was included on the Voyager Golden Record, launched on the Voyager probes in 1977, in case any extraterrestrial intelligence could decode her thoughts, which included what it was like to fall in love.{{Citation needed|date=January 2023}}

History

File:1st-eeg.png in 1924. The upper tracing is EEG, and the lower is a 10 Hz timing signal.]]

File:HansBerger Univ Jena.jpeg]]

In 1875, Richard Caton (1842–1926), a physician practicing in Liverpool, presented his findings about electrical phenomena of the exposed cerebral hemispheres of rabbits and monkeys in the British Medical Journal. In 1890, Polish physiologist Adolf Beck published an investigation of spontaneous electrical activity of the brain of rabbits and dogs that included rhythmic oscillations altered by light. Beck started experiments on the electrical brain activity of animals. Beck placed electrodes directly on the surface of the brain to test for sensory stimulation. His observation of fluctuating brain activity led to the conclusion of brain waves.{{cite journal |vauthors=Coenen A, Fine E, Zayachkivska O |date=2014 |title=Adolf Beck: a forgotten pioneer in electroencephalography |journal=Journal of the History of the Neurosciences |volume=23 |issue=3 |pages=276–286 |doi=10.1080/0964704x.2013.867600 |pmid=24735457 |s2cid=205664545}}

In 1912, Ukrainian physiologist Vladimir Vladimirovich Pravdich-Neminsky published the first animal EEG and the evoked potential of the mammalian (dog).{{cite journal |vauthors=Pravdich-Neminsky VV |year=1913 |title=Ein Versuch der Registrierung der elektrischen Gehirnerscheinungen |journal=Zentralblatt für Physiologie |volume=27 |pages=951–60}} In 1914, Napoleon Cybulski and Jelenska-Macieszyna photographed EEG recordings of experimentally induced seizures.{{citation needed|date=June 2022}}

German physiologist and psychiatrist Hans Berger (1873–1941) recorded the first human EEG in 1924.{{cite journal |vauthors=Haas LF |date=January 2003 |title=Hans Berger (1873–1941), Richard Caton (1842–1926), and electroencephalography |journal=Journal of Neurology, Neurosurgery, and Psychiatry |volume=74 |issue=1 |pages=9 |doi=10.1136/jnnp.74.1.9 |pmc=1738204 |pmid=12486257}} Expanding on work previously conducted on animals by Richard Caton and others, Berger also invented the electroencephalograph (giving the device its name), an invention described "as one of the most surprising, remarkable, and momentous developments in the history of clinical neurology".{{cite conference |date=June 2002 |title=The origins of EEG. |url=http://www.bri.ucla.edu/nha/ishn/ab24-2002.htm |conference=7th Annual Meeting of the International Society for the History of the Neurosciences (ISHN) |vauthors=Millet D |access-date=November 27, 2010 |archive-date=September 8, 2020 |archive-url=https://web.archive.org/web/20200908035306/http://www.bri.ucla.edu/nha/ishn/ab24-2002.htm |url-status=dead }} His discoveries were first confirmed by British scientists Edgar Douglas Adrian and B. H. C. Matthews in 1934 and developed by them.

In 1934, Fisher and Lowenbach first demonstrated epileptiform spikes. In 1935, Gibbs, Davis and Lennox described interictal spike waves and the three cycles/s pattern of clinical absence seizures, which began the field of clinical electroencephalography.{{cite journal |vauthors=Gibbs FA, Davis H, Lennox WG |date=December 1935 |title=The Electro-Encephalogram in Epilepsy and in Conditions of Impaired Consciousness |journal=Archives of Neurology and Psychiatry |volume=34 |issue=6 |pages=1133 |doi=10.1001/archneurpsyc.1935.02250240002001}} Subsequently, in 1936 Gibbs and Jasper reported the interictal spike as the focal signature of epilepsy. The same year, the first EEG laboratory opened at Massachusetts General Hospital.{{citation needed|date=June 2022}}

Franklin Offner (1911–1999), professor of biophysics at Northwestern University developed a prototype of the EEG that incorporated a piezoelectric inkwriter called a Crystograph (the whole device was typically known as the Offner Dynograph).

In 1947, The American EEG Society was founded and the first International EEG congress was held. In 1953 Aserinsky and Kleitman described REM sleep.

In the 1950s, William Grey Walter developed an adjunct to EEG called EEG topography, which allowed for the mapping of electrical activity across the surface of the brain. This enjoyed a brief period of popularity in the 1980s and seemed especially promising for psychiatry. It was never accepted by neurologists and remains primarily a research tool.

File:Chuck Kayser with oscilloscope fq977v01f.tiff, 1965]]

An electroencephalograph system manufactured by Beckman Instruments was used on at least one of the Project Gemini manned spaceflights (1965–1966) to monitor the brain waves of astronauts on the flight. It was one of many Beckman Instruments specialized for and used by NASA.{{cite news |date=March 3, 1965 |title=Beckman Instruments Supplying Medical Flight Monitoring Equipment |pages=4–5 |work=Space News Roundup |url=https://historycollection.jsc.nasa.gov/JSCHistoryPortal/history/roundups/issues/65-03-03.pdf |url-status=live |access-date=August 7, 2019 |archive-url=https://web.archive.org/web/20190807120214/https://historycollection.jsc.nasa.gov/JSCHistoryPortal/history/roundups/issues/65-03-03.pdf |archive-date=August 7, 2019}}

The first instance of the use of EEG to control a physical object, a robot, was in 1988. The robot would follow a line or stop depending on the alpha activity of the subject. If the subject relaxed and closed their eyes therefore increasing alpha activity, the bot would move. Opening their eyes thus decreasing alpha activity would cause the robot to stop on the trajectory.{{Cite book | vauthors = Bozinovski S |chapter=Controlling Robots Using EEG Signals, Since 1988 | veditors = Markovski S, Gusev M |title=ICT Innovations 2012 |date=2013 |series=Advances in Intelligent Systems and Computing |language=en |location=Berlin, Heidelberg |publisher=Springer |volume=207 |pages=1–11 |doi=10.1007/978-3-642-37169-1_1 |isbn=978-3-642-37169-1 }}